Adaptive error detection for HDR/PDR brachytherapy: guidance for decision making during real-time in vivo point dosimetry.

PURPOSE This study presents an adaptive error detection algorithm (AEDA) for real-time in vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction of the dosimeter position. Instead, the treatment is judged based on dose rate comparisons between measurements and calculations of the most viable dosimeter position provided by the AEDA in a data driven approach. As a result, the AEDA compensates for false error cases related to systematic effects of the dosimeter position reconstruction. Given its nearly exclusive dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. METHODS In the event of a measured potential treatment error, the AEDA proposes the most viable dosimeter position out of alternatives to the original reconstruction by means of a data driven matching procedure between dose rate distributions. If measured dose rates do not differ significantly from the most viable alternative, the initial error indication may be attributed to a mispositioned or misreconstructed dosimeter (false error). However, if the error declaration persists, no viable dosimeter position can be found to explain the error, hence the discrepancy is more likely to originate from a misplaced or misreconstructed source applicator or from erroneously connected source guide tubes (true error). RESULTS The AEDA applied on two in vivo dosimetry implementations for pulsed dose rate BT demonstrated that the AEDA correctly described effects responsible for initial error indications. The AEDA was able to correctly identify the major part of all permutations of simulated guide tube swap errors and simulated shifts of individual needles from the original reconstruction. Unidentified errors corresponded to scenarios where the dosimeter position was sufficiently symmetric with respect to error and no-error source position constellations. The AEDA was able to correctly identify all false errors represented by mispositioned dosimeters contrary to an error detection algorithm relying on the original reconstruction. CONCLUSIONS The study demonstrates that the AEDA error identification during HDR/PDR BT relies on a stable dosimeter position rather than on an accurate dosimeter reconstruction, and the AEDA's capacity to distinguish between true and false error scenarios. The study further shows that the AEDA can offer guidance in decision making in the event of potential errors detected with real-time in vivo point dosimetry.

[1]  Natalka Suchowerska,et al.  Clinical trials of a urethral dose measurement system in brachytherapy using scintillation detectors. , 2011, International journal of radiation oncology, biology, physics.

[2]  J. Williamson,et al.  Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations. , 2004 .

[3]  N Suchowerska,et al.  Real-time verification of HDR brachytherapy source location: implementation of detector redundancy , 2004, Physics in medicine and biology.

[4]  Kari Tanderup,et al.  Time-resolved in vivo luminescence dosimetry for online error detection in pulsed dose-rate brachytherapy. , 2009, Medical physics.

[5]  L. Lindvold,et al.  Temperature variations as a source of uncertainty in medical fiber-coupled organic plastic scintillator dosimetry , 2013 .

[6]  D. Georg,et al.  In-vivo dosimetry for gynaecological brachytherapy: physical and clinical considerations. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[7]  J. Edmund,et al.  Temperature dependence of the Al2O3:C response in medical luminescence dosimetry , 2007 .

[8]  E. M. Pedersen,et al.  Clinical feasibility of combined intracavitary/interstitial brachytherapy in locally advanced cervical cancer employing MRI with a tandem/ring applicator in situ and virtual preplanning of the interstitial component. , 2013, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[9]  L. Beaulieu,et al.  A phantom study of an in vivo dosimetry system using plastic scintillation detectors for real-time verification of 192Ir HDR brachytherapy. , 2011, Medical physics.

[10]  J. Williamson,et al.  Report of the Task Group 186 on model-based dose calculation methods in brachytherapy beyond the TG-43 formalism: current status and recommendations for clinical implementation. , 2012, Medical physics.

[11]  Kari Tanderup,et al.  Stem signal suppression in fiber-coupled Al2O3:C dosimetry for 192Ir brachytherapy , 2011 .

[12]  Grant V. M. Williams,et al.  Fiber-optic-coupled RbMgF 3 :Eu 2+ for remote radiation dosimetry , 2011 .

[13]  Norberto Chiodini,et al.  Ce-doped optical fibre as radioluminescent dosimeter in radiotherapy , 2008 .

[14]  J. Lambert,et al.  Dose mapping of the rectal wall during brachytherapy with an array of scintillation dosimeters. , 2010, Medical physics.

[15]  In vivo dosimetry of high-dose-rate interstitial brachytherapy in the pelvic region: use of a radiophotoluminescence glass dosimeter for measurement of 1004 points in 66 patients with pelvic malignancy. , 2008, International journal of radiation oncology, biology, physics.

[16]  Evaluation of a novel 4D in vivo dosimetry system. , 2009, Medical physics.

[17]  A Haworth,et al.  Source position verification and dosimetry in HDR brachytherapy using an EPID. , 2013, Medical physics.

[18]  Steffen Greilich,et al.  Temperature coefficients for in vivo RL and OSL dosimetry using Al2O3:C , 2008 .

[19]  Sören Mattsson,et al.  Prevention of accidental exposures to patients undergoing radiation therapy , 2000 .

[20]  S. Beddar,et al.  Temperature dependence of BCF plastic scintillation detectors , 2013, Physics in medicine and biology.

[21]  E. M. Pedersen,et al.  Apparent diffusion coefficients in GEC ESTRO target volumes for image guided adaptive brachytherapy of locally advanced cervical cancer , 2010, Acta oncologica.

[22]  J. M. Fontbonne,et al.  Scintillating fiber dosimeter for radiation therapy accelerator , 2001 .

[23]  Kari Tanderup,et al.  In vivo dosimetry in brachytherapy. , 2013, Medical physics.

[24]  F. Verhaegen,et al.  In vivo dosimetry for gynaecological brachytherapy using a novel position sensitive radiation detector: feasibility study. , 2012, Medical physics.

[25]  M Petasecca,et al.  The feasibility study and characterization of a two-dimensional diode array in "magic phantom" for high dose rate brachytherapy quality assurance. , 2013, Medical physics.

[26]  T. Monro,et al.  Characterisation of a real-time fibre-coupled beryllium oxide (BeO) luminescence dosimeter in X-ray beams , 2013 .

[27]  R. E. P. Taylor,et al.  Sci—Sat AM(2): Brachy — 05: Fast Monte Carlo Dose Calculations for Brachytherapy with BrachyDose , 2010 .

[28]  Steffen Greilich,et al.  Fiber-coupled radioluminescence dosimetry with saturated Al2O3:C crystals: Characterization in 6 and 18 MV photon beams , 2011 .

[29]  F. Spano,et al.  Radioluminescence of rare-earth doped potassium yttrium fluorides crystals , 2011 .

[30]  Aisling Haughey,et al.  Evaluation of linear array MOSFET detectors for in vivo dosimetry to measure rectal dose in HDR brachytherapy , 2011, Australasian Physical & Engineering Sciences in Medicine.

[31]  Thomas K. Plant,et al.  SSPM based radiation sensing: Preliminary laboratory and clinical results , 2011 .

[32]  Kari Tanderup,et al.  Identifying afterloading PDR and HDR brachytherapy errors using real-time fiber-coupled Al(2)O(3):C dosimetry and a novel statistical error decision criterion. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[33]  Kari Tanderup,et al.  MRI-guided 3D optimization significantly improves DVH parameters of pulsed-dose-rate brachytherapy in locally advanced cervical cancer. , 2008, International journal of radiation oncology, biology, physics.

[34]  K. Tanderup,et al.  Geometric stability of intracavitary pulsed dose rate brachytherapy monitored by in vivo rectal dosimetry. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[35]  L. Beaulieu,et al.  On the use of a single-fiber multipoint plastic scintillation detector for 192 Ir high-dose-rate brachytherapy. , 2013, Medical physics.

[36]  P. Metcalfe,et al.  In vivo real-time dosimetric verification in high dose rate prostate brachytherapy. , 2011, Medical physics.