Heat transfer analysis and experimental verification of casted heat exchanger in non-icing and icing conditions in winter

Seawater-source heat pump systems (SWHP) are recognized to be outstanding heating, cooling and water heating systems. A large number of SWHP systems have been used in residential and commercial buildings in coastal areas due to the attractive advantages of high efficiency and environmental friendliness. In this paper, two mathematical models that described heat transfer process of casted heat exchanger (CHE) adopted by SWHP systems in the icing and non-icing conditions in winter have been developed and validated by an experimental study. The CHE is consisted of pipes immersed in the seawater and used for transferring heat between the seawater and the heat exchanger pipes of the SWHP. In addition, a computer code has been implemented to simulate the effects of flow rate of the secondary refrigerant, length of the CHE and the temperature of the seawater on the heat transfer performance. The effect of the ice outside the pipe due to the low seawater temperature on heat transfer has been discussed and the comparison of the heat transfer rate in two conditions demonstrates that the effect of icing on heat transfer performance is great. As a result, application of SWHP systems with CHE in coastal areas in China is feasible due to the favorable geographical conditions and environment.

[1]  Satoru Okamoto A heat pump system with a latent heat storage utilizing seawater installed in an aquarium , 2006 .

[2]  Hongxing Yang,et al.  Vertical-borehole ground-coupled heat pumps: A review of models and systems , 2010 .

[3]  Guoqiang Zhang,et al.  The performance of an open-loop lake water heat pump system in south China , 2006 .

[4]  J. P. Holman,et al.  Experimental methods for engineers , 1971 .

[5]  Refrigerating ASHRAE handbook. Heating, ventilating, and air-conditioning systems and applications , 1987 .

[6]  W. H. Leong,et al.  Analysis of ground source heat pumps with horizontal ground heat exchangers for northern Japan , 2009 .

[7]  Mustafa Inalli,et al.  Modelling a ground-coupled heat pump system using adaptive neuro-fuzzy inference systems , 2008 .

[8]  Mustafa Inalli,et al.  Numerical and experimental analysis of a horizontal ground-coupled heat pump system , 2007 .

[9]  Mustafa Inalli,et al.  In-situ thermal response test for ground source heat pump system in Elazığ, Turkey , 2009 .

[10]  Mehmet Esen,et al.  Energy and exergy analysis of a ground-coupled heat pump system with two horizontal ground heat exchangers , 2007 .

[11]  Guohui Gan,et al.  Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers , 2010 .

[12]  O. Büyükalaca,et al.  Experimental investigation of Seyhan River and dam lake as heat source–sink for a heat pump , 2003 .

[13]  Mustafa Inalli,et al.  Modelling of a vertical ground coupled heat pump system by using artificial neural networks , 2009, Expert Syst. Appl..

[14]  W. S. Joyce,et al.  Lake-Source Cooling , 2002 .

[15]  S. Kavanaugh Design considerations for ground and water source heat pumps in southern climates , 1989 .

[16]  Yingxin Zhu,et al.  District cooling and heating with seawater as heat source and sink in Dalian, China , 2007 .

[17]  Yasunori Akashi,et al.  Effects of utilizing seawater as a cooling source system in a commercial complex , 2007 .

[18]  Mustafa Inalli,et al.  Experimental thermal performance evaluation of a horizontal ground-source heat pump system , 2004 .

[19]  Xianting Li,et al.  A new integrated system with cooling storage in soil and ground-coupled heat pump. , 2008 .

[20]  Stephen P. Kavanaugh,et al.  Ground Source Heat Pumps : Design of Geothermal Systems for Commercial and Institutional Buildings , 1997 .

[21]  Mustafa Inalli,et al.  Temperature distributions in boreholes of a vertical ground-coupled heat pump system , 2009 .