Development of an optical fibre reflectance sensor for p-aminophenol detection based on immobilised bis-8-hydroxyquinoline.

2,2'-(1,4-Phenylenedivinylene)bis-8-hydroxyquinoline (PBHQ), a highly sensitive reagent used for the colorimetric determination of p-aminophenol (PAP), was successfully immobilised on XAD-7 and coupled with optical fibres to investigate a sensor-based approach for determining p-aminophenol. The solid-state sensor is based on the reaction of PAP with PBHQ in presence of an oxidant to produce an indophenol dye. The reflectance measurements were carried out at a wavelength of 647 nm since it yielded the largest divergence different in reflectance spectra before and after reaction with the analyte. The linear dynamic range of PAP was found within the concentration range of 0.1-2.18 mg l(-1) with its LOD of 0.02 mg l(-1). The sensor response from different probes (n=7) gave a R.S.D. of 4.4% at 1.09 mg l(-1) PAP concentration. The response time of the optical one-shot sensor was 5 min for a stable solution. As this PAP sensor is irreversible, a fresh sensor has to be used for each measurement. All the experimental parameters were optimized for the determination of PAP. Using the optical sensing probe, PAP in pharmaceutical wastewater and paracetamol was determined. The effect of potential interferences such as inorganic and organic compounds was also evaluated. Potential on-site determination of PAP with such sensors can indirectly aid detection of organo-phosphorus nerve agents and pesticides in the field by inhibition of acetylcholine esterase-catalyzed hydrolysis of p-aminophenyl acetate to p-aminophenol.

[1]  Jean-Louis Marty,et al.  Screen-printed electrode based on AChE for the detection of pesticides in presence of organic solvents. , 2002, Talanta.

[2]  W. H. Kimball,et al.  The effect of accelerated weathering on the degradation of polymeric films , 1978 .

[3]  A. Molina-Díaz,et al.  A flow-through solid phase UV spectrophotometric biparameter sensor for the sequential determination of ascorbic acid and paracetamol , 2000 .

[4]  Musa Ahmad,et al.  Fibre optic reflectance sensor for the determination of aluminium(III) in aqueous environment , 1994 .

[5]  Safia Ahmed,et al.  Degradation of 4-aminophenol by newly isolated Pseudomonas sp. strain ST-4 , 2006 .

[6]  Otto S. Wolfbeis,et al.  Optical sensors for determination of heavy metal ions , 1997 .

[7]  A. Avramescu,et al.  Detection of organophosphorus insecticides with immobilized acetylcholinesterase – comparative study of two enzyme sensors , 2002, Analytical and bioanalytical chemistry.

[8]  Chun-Ze Lai,et al.  Flow injection determination of p-aminophenol at trace level using inhibited luminol-dimethylsulfoxide-NaOH-EDTA chemiluminescence. , 2005, Water research.

[9]  H. Filik,et al.  Sequential spectrophotometric determination of paracetamol and p-aminophenol with 2,2'-(1,4-phenylenedivinylene) bis-8-hydroxyquinoline as a novel coupling reagent after microwave assisted hydrolysis , 2005 .

[10]  K. Lau,et al.  Solid-state ammonia sensor based on Berthelot's reaction , 2004 .

[11]  F Pariente,et al.  Enzyme support systems for biosensor applications based on gold-coated nylon meshes. , 1996, Biosensors & bioelectronics.

[12]  Zhonghai Zhang,et al.  Rapid amperometric detection of coliforms based on MWNTs/Nafion composite film modified glass carbon electrode. , 2007, Talanta.

[13]  Subrayal M Reddy,et al.  Determination of 4-aminophenol using the quartz crystal microbalance sensor. , 2002, The Analyst.

[14]  P. Campíns-Falcó,et al.  Improved detection limit for ammonium/ammonia achieved by Berthelot's reaction by use of solid-phase extraction coupled to diffuse reflectance spectroscopy , 2005 .

[15]  W. Rudolf Seitz,et al.  Immobilized morin as fluorescence sensor for determination of aluminum(III) , 1983 .

[16]  S. A. Momin,et al.  Optosensing of chlorine gas using a dry reagent strip and diffuse reflectance spectrophotometry , 1991 .

[17]  C. Ojeda,et al.  Determination of paracetamol: historical evolution. , 2006 .

[18]  R. Apak,et al.  Spectrophotometric determination of paracetamol in urine with tetrahydroxycalix[4]arene as a coupling reagent and preconcentration with triton X-114 using cloud point extraction. , 2006, Chemical & pharmaceutical bulletin.

[19]  J. Lach,et al.  Stability of aqueous solutions of N-acetyl-p-aminophenol. , 1961, Journal of pharmaceutical sciences.

[20]  Félix Pariente,et al.  Amperometric flow-through biosensor for the determination of pesticides , 1995 .