A screen-printed biosensor using pyruvate oxidase for rapid determination of phosphate in synthetic wastewater

A screen-printed phosphate biosensor based on immobilized pyruvate oxidase (PyOD, E.C. 1.2.3.3) has been developed for monitoring phosphate concentrations in a sequencing batch reactor (SBR) system. The enzyme was immobilized by a nafion matrix and covered a poly(carbamoyl) sulfonate (PCS) hydrogel on a screen-printed electrode. PyOD consumes phosphate in the presence of pyruvate and oxygen and generates hydrogen peroxide (H2O2), carbon dioxide and acetylphosphate. The electroactive H2O2, monitored at +420 mV vs Ag/AgCl, is generated in proportion to the concentration of phosphate. The sensor has a fast response time (2 s) and a short recovery period (2 min). The time required for one measurement using this phosphate biosensor was 4 min, which was faster than the time required using a commercial phosphate testing kit (10 min). The sensor has a linear range from 7.5 μM to 625 μM phosphate with a detection limit of 3.6 μM. There was good agreement (R2=0.9848) between the commercial phosphate testing kit and the phosphate sensor in measurements of synthetic wastewater in a SBR system. This sensor maintained a high working stability (>85%) after 12 h of operation and involved a simple operation procedure. It therefore serves as a useful tool for rapid and accurate phosphate measurements in the SBR system and probably for process control.

[1]  N. Chaniotakis,et al.  Potentiometric phosphate selective electrode based on a multidendate—tin (IV) carrier , 1993 .

[2]  S O Engblom,et al.  The phosphate sensor. , 1998, Biosensors & bioelectronics.

[3]  R. Renneberg,et al.  Biosensor for rapid phosphate monitoring in a sequencing batch reactor (SBR) system. , 2003, Biosensors & bioelectronics.

[4]  X. Correig,et al.  Reagentless carbon paste phosphate biosensors: preliminary studies , 1998 .

[5]  K. Schleifer,et al.  Purification and biochemical characterization of pyruvate oxidase from Lactobacillus plantarum , 1984, Journal of bacteriology.

[6]  M. A. Bello,et al.  Determination of Phosphate in Cola Beverages Using Nonsuppressed Ion Chromatography: An Experiment Introducing Ion Chromatography for Quantitative Analysis , 1996 .

[7]  Frieder W. Scheller,et al.  Plant tissue hybrid electrode for determination of phosphate and fluoride , 1984 .

[8]  F W Scheller,et al.  Enhancing biosensor performance using multienzyme systems. , 1993, Trends in biotechnology.

[9]  Lindawati,et al.  Application of biochemical oxygen demand (BOD) biosensor for optimization of biological carbon and nitrogen removal from synthetic wastewater in a sequencing batch reactor system. , 2004, Biosensors & bioelectronics.

[10]  U. Wollenberger,et al.  Biosensor for sensitive phosphate detection , 1992 .

[11]  I. Karube,et al.  A novel biosensor system for the determination of phosphate , 1996 .

[12]  Phosphate Sensor Composed from Immobilized Pyruvate Oxidase and an Oxygen Electrode , 1991 .

[13]  C. H. Fiske,et al.  THE COLORIMETRIC DETERMINATION OF PHOSPHORUS , 1925 .

[14]  F. Scheller,et al.  Coupled enzyme reactions for novel biosensors , 1986 .

[15]  G G Guilbault,et al.  A phosphate-selective electrode based on immobilized alkaline phosphatase and glucose oxidase. , 1975, Analytica chimica acta.

[16]  R. Renneberg,et al.  An amperometric biosensor for determining amino acids using a bienzymatic system containing amino acid oxidase and protease , 2002, Biotechnology Letters.

[17]  J. V. Bannister,et al.  Amperometric dertermination of phosphate ions by biosensor , 1992 .

[18]  G. Bortone,et al.  Biological nutrient removal in a full-scale SBR treating piggery wastewater: results and modelling. , 2001, Water science and technology : a journal of the International Association on Water Pollution Research.

[19]  P. Coulet,et al.  Phosphate-sensitive enzyme electrode : a potential sensor for environment control , 1990 .

[20]  J. Luong,et al.  An FIA biosensor system for the determination of phosphate. , 1991, Biosensors & bioelectronics.

[21]  U Wollenberger,et al.  Research and development of biosensors. A review. , 1989, The Analyst.

[22]  G. Guilbault,et al.  Ion Selective Electrodes for Phosphate Using Enzyme Systems , 1976 .

[23]  R. Gennis,et al.  Role of the divalent metal cation in the pyruvate oxidase reaction. , 1982, The Journal of biological chemistry.

[24]  D. Cairns Phosphorus in the global environment: Transfers, cycles and management , 1997 .

[25]  R. Renneberg,et al.  Measurement of biodegradable substances using the salt-tolerant yeast Arxula adeninivorans for a microbial sensor immobilized with poly(carbamoyl) sulfonate (PCS) Part I: Construction and characterization of the microbial sensor. , 1999, Biosensors & bioelectronics.

[26]  Peter W. Alexander,et al.  Flow-injection Potentiometric Detection of Phosphates Using a Metallic Cobalt Wire Ion-selective Electrode , 1997 .

[27]  Hong Yang,et al.  Comparison of effectiveness of different ashing auxiliaries for determination of phosphorus in natural waters, aquatic organisms and sediments by ignition method. , 2003, Water research.

[28]  H. Tiessen Phosphorous in the global environment: transfers, cycles and management , 1995 .

[29]  G. A. Hoffman,et al.  Effect of non-Newtonian solutions on the behavior of the thermal pulse time-of-flight flowmeter , 1984 .