Dynamic curvature sensing employing ionic-polymer–metal composite sensors

A dynamic curvature sensor is presented based on ionic-polymer–metal composite (IPMC) for curvature monitoring of deployable/inflatable dynamic space structures. Monitoring the curvature variation is of high importance in various engineering structures including shape monitoring of deployable/inflatable space structures in which the structural boundaries undergo a dynamic deployment process. The high sensitivity of IPMCs to the applied deformations as well as its flexibility make IPMCs a promising candidate for sensing of dynamic curvature changes. Herein, we explore the dynamic response of an IPMC sensor strip with respect to controlled curvature deformations subjected to different forms of input functions. Using a specially designed experimental setup, the voltage recovery effect, phase delay, and rate dependency of the output voltage signal of an IPMC curvature sensor are analyzed. Experimental results show that the IPMC sensor maintains the linearity, sensitivity, and repeatability required for curvature sensing. Besides, in order to describe the dynamic phenomena such as the rate dependency of the IPMC sensor, a chemo-electro-mechanical model based on the Poisson–Nernst–Planck (PNP) equation for the kinetics of ion diffusion is presented. By solving the governing partial differential equations the frequency response of the IPMC sensor is derived. The physical model is able to describe the dynamic properties of the IPMC sensor and the dependency of the signal on rate of excitations.

[1]  Mohsen Shahinpoor,et al.  Characterizing of Ionic Polymer-Metal Composites (IPMC) for Sensitive Curvature Measurement , 2010 .

[2]  Mohsen Shahinpoor,et al.  Mass Transfer Induced Hydraulic Actuation in Ionic Polymer-Metal Composites , 2002 .

[3]  Mohsen Shahinpoor,et al.  Charge modeling of ionic polymer-metal composites for dynamic curvature sensing , 2011, Smart Structures and Materials + Nondestructive Evaluation and Health Monitoring.

[4]  J. O. Simpson,et al.  Ionic polymer-metal composites (IPMCs) as biomimetic sensors, actuators and artificial muscles - a review , 1998 .

[5]  K. Kim,et al.  Ionic polymer–metal composites: IV. Industrial and medical applications , 2005 .

[6]  K. Kim,et al.  Ionic polymer-metal composites: I. Fundamentals , 2001 .

[7]  Maurizio Porfiri,et al.  Charge dynamics in ionic polymer metal composites , 2008 .

[8]  M. Ozawa,et al.  Soft micromanipulation device with multiple degrees of freedom consisting of high polymer gel actuators , 1999, Technical Digest. IEEE International MEMS 99 Conference. Twelfth IEEE International Conference on Micro Electro Mechanical Systems (Cat. No.99CH36291).

[9]  David Griffiths,et al.  Development of Ionic Polymer Metallic Composites as Sensors , 2008 .

[10]  Sia Nemat-Nasser,et al.  Electromechanical response of ionic polymer-metal composites , 2000 .

[11]  Mohsen Shahinpoor New effect in ionic polymeric gels: the ionic flexogelectric effect , 1995, Smart Structures.

[12]  E. Biddiss,et al.  Electroactive polymeric sensors in hand prostheses: bending response of an ionic polymer metal composite. , 2006, Medical engineering & physics.

[13]  Xiaobo Tan,et al.  A dynamic model for ionic polymer–metal composite sensors , 2007 .