Error Analysis of Time Delay Based on Ultrasonic Phased Array Structural Health Monitoring

Ultrasonic phased array technology becomes significant in structural health monitoring with its flexible beam deflection and strong focusing performance. The transducer is used to complete the multiple directions scanning of the structure. During the process of beam scanning, the signal exciting from each element needs to add a time delay in time domain, due to the difference to the distance from each element to the far field target point, so that the excitation signal can reach the target point and the far field at the same time. Besides, in the process of receiving and transmitting process, it also needs to add a time delay for the response signal, so that the sensor can receive the reflection signal from the preset deflection angle. Therefore, the error will be generated in the calculation of time delay. Making the anti-rust aluminum plate as the experimental object, the process of ultrasonic phased array structural health monitoring will be introduced. And then the reason of time delay error will be pointed out and analyzed.

[1]  Yonghong Zhang,et al.  Near-Field Ultrasonic Phased Array Deflection Focusing Based CFRP Wing Box Structural Health Monitoring , 2013, Int. J. Distributed Sens. Networks.

[2]  Jennifer E. Michaels,et al.  Block-sparse reconstruction and imaging for lamb wave structural health monitoring , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[3]  Michael Unser,et al.  Optimality of Operator-Like Wavelets for Representing Sparse AR(1) Processes , 2013, IEEE Transactions on Signal Processing.

[4]  Bin Liu,et al.  Omni-directional damage detection and localization with a cruciform piezoelectric ultrasonic phased array , 2015 .

[5]  Mark R. Pickering,et al.  High-Precision OFDM-Based Multiple Ultrasonic Transducer Positioning Using a Robust Optimization Approach , 2016, IEEE Sensors Journal.

[6]  Fuzeng Zhang,et al.  Ultrasonic phased array detection of internal defects in composite insulators , 2016, IEEE Transactions on Dielectrics and Electrical Insulation.

[7]  G. I. Athanasopoulos,et al.  Circuit design and simulation of a transmit beamforming ASIC for high-frequency ultrasonic imaging systems , 2011, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Lorenzo Capineri,et al.  An Integrated Acousto/Ultrasonic Structural Health Monitoring System for Composite Pressure Vessels , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[9]  Swapna Banerjee,et al.  Architecture of a real-time delay calculator for digital beamforming in ultrasound system , 2016, IET Circuits Devices Syst..

[10]  Sai Ji,et al.  Structural Damage Detection using Wireless Intelligent Sensor Networks , 2012 .

[11]  Cristina Diego,et al.  Improved Ultrasonic Phased Array Based on Encoded Transmissions for Obstacle Detection , 2015, IEEE Sensors Journal.

[12]  Xingming Sun,et al.  Fast Motion Estimation Based on Content Property for Low-Complexity H.265/HEVC Encoder , 2016, IEEE Transactions on Broadcasting.

[13]  Ammar B. Kouki,et al.  Development and Characterization of a Novel Interdigitated Capacitive Strain Sensor for Structural Health Monitoring , 2015, IEEE Sensors Journal.

[14]  P. Wilcox,et al.  Effects of array transducer inconsistencies on total focusing method imaging performance , 2011 .