Optimized design for three port transformer considering leakage inductance and parasitic capacitance

The power flow capability of high frequency phase-shifted dc-dc converter depends on transformer leakage inductance and switching frequency. The design of multi-port transformer requires optimized volume and losses with required leakage inductance for rated power flow. Use of fast-switching SiC devices also demand low inter-winding parasitic capacitance for reduced common mode current. The work in this paper focuses on loss-volume optimized design of three port high frequency transformer integrating PV and Energy Storage(ES) based on leakage inductance and parasitic capacitance model. Two laboratory prototypes of 50kHz and 100kHz operating frequency have been designed to verify the leakage and parasitic capacitance model based design and the losses of the transformers.

[1]  Subhashish Bhattacharya,et al.  Split-winding type three limb core structured HF transformer for integrating PV and energy storage(ES) , 2017, 2017 IEEE Applied Power Electronics Conference and Exposition (APEC).

[2]  Subhashish Bhattacharya,et al.  Modular isolated DC-DC converter with multi-limb transformer for interfacing of renewable energy sources , 2015, 2015 IEEE Applied Power Electronics Conference and Exposition (APEC).

[3]  Subhashish Bhattacharya,et al.  Modelling, design and analysis of three limb high frequency transformer including transformer parasitics, for SiC Mosfet based three port DAB , 2016, IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society.

[4]  Subhashish Bhattacharya,et al.  Operation of hybrid multi-terminal DC system under normal and DC fault operating conditions , 2015, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[5]  Marian K. Kazimierczuk,et al.  Winding resistance of litz-wire and multi-strand inductors , 2012 .

[6]  Subhashish Bhattacharya,et al.  Power flow control and ZVS analysis of three limb high frequency transformer based three-port DAB , 2016, 2016 IEEE Applied Power Electronics Conference and Exposition (APEC).

[7]  Hans Ertl,et al.  Analysis of Ultra-fast Inverter Switching Transition (dv/dt) Impact based on SiC Semi-conductors to Pre-active Insulation Monitoring of High Power , 2015 .

[8]  Johann W. Kolar,et al.  Optimum Number of Cascaded Cells for High-Power Medium-Voltage AC–DC Converters , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[9]  S. Tiwari,et al.  Experimental performance evaluation of two commercially available, 1.2 kV half-bridge SiC MOSFET modules , 2016, IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society.

[10]  J.W. Kolar,et al.  An Isolated Three-Port Bidirectional DC-DC Converter With Decoupled Power Flow Management , 2008, IEEE Transactions on Power Electronics.

[11]  Subhashish Bhattacharya,et al.  Grid connected CM noise considerations of a three-phase multi-stage SST , 2015, 2015 9th International Conference on Power Electronics and ECCE Asia (ICPE-ECCE Asia).

[12]  Subhashish Bhattacharya,et al.  Decoupled power flow using phase shift control and ZVS cases for a three limb high frequency transformer based three-port DAB integrating PV and energy storage , 2016, 2016 IEEE Industry Applications Society Annual Meeting.

[13]  Charles R. Sullivan,et al.  Accurate prediction of ferrite core loss with nonsinusoidal waveforms using only Steinmetz parameters , 2002, 2002 IEEE Workshop on Computers in Power Electronics, 2002. Proceedings..

[14]  Subhashish Bhattacharya,et al.  ZVS analysis and power flow control for three limb transformer enabled SiC Mosfet based three port DAB integrating PV and Energy Storage(ES) , 2016, 2016 IEEE Energy Conversion Congress and Exposition (ECCE).

[15]  Subhashish Bhattacharya Transforming the transformer , 2017, IEEE Spectrum.