To Wash or Not to Wash? Comparison of Patient Outcome after Infusion of Cryopreserved Autologous Hematopoietic Stem Cells before and after the Replacement of Manual Washing by Bedside Thawing

Background: Prior to infusion, cryopreserved autologous peripheral blood stem cell (auto-PBSC) grafts can either be thawed at the bedside or thawed and washed at the laboratory. At our center, manual washing of grafts prior to infusion was discontinued in April 2012 and bedside thawing was implemented. Methods: This study compares the outcomes of two patient groups who received auto-PBSC either after post-thaw washing (n = 84) or bedside thawing (n = 83). Results: No life-threatening infusion-related side effects were reported in either group. There was no significant difference in the mean CD34+ cells/kg dose of infused auto-PBSC in the two groups (p = 0.41), nor in the number of days to neutrophils > 0.5 × 109/L (p = 0.14), days to platelets > 20 × 109/L (p = 0.64), or days to platelets > 50 × 109/L (p = 0.62) after transplant. There was also no difference in the number of days on total parenteral nutrition (p = 0.69), days on G-CSF therapy (p = 0.48), or days with fever (p = 0.73). Finally, there was no significant difference in the number of red cell units transfused (p = 0.32), or platelet units transfused (p = 0.94) after the transplant. One-hundred-day mortality was identical in the two groups (2.4%). Conclusion: Both thawing procedures are safe and result in acceptable engraftment and patient outcomes.

[1]  B. Grossman,et al.  Adverse events of cryopreserved hematopoietic stem cell infusions in adults: a single‐center observational study , 2017, Transfusion.

[2]  G. Dixit,et al.  Single Versus Dual Platform Analysis for Hematopoietic Stem Cell Enumeration Using ISHAGE Protocol , 2017, Indian Journal of Hematology and Blood Transfusion.

[3]  M. Marconi,et al.  An update on methods for cryopreservation and thawing of hemopoietic stem cells. , 2016, Transfusion and apheresis science : official journal of the World Apheresis Association : official journal of the European Society for Haemapheresis.

[4]  S. Akel,et al.  Current thawing and infusion practice of cryopreserved cord blood: the impact on graft quality, recipient safety, and transplantation outcomes , 2014, Transfusion.

[5]  R. Bouabdallah,et al.  Automated washing of autologous hematopoietic stem cell grafts after thawing does not impair engraftment , 2014, Bone Marrow Transplantation.

[6]  S. Heimfeld,et al.  Hematopoietic SCT with cryopreserved grafts: adverse reactions after transplantation and cryoprotectant removal before infusion , 2014, Bone Marrow Transplantation.

[7]  M. Kattan,et al.  Autologous haematopoietic stem cell mobilisation in multiple myeloma and lymphoma patients: a position statement from the European Group for Blood and Marrow Transplantation , 2014, Bone Marrow Transplantation.

[8]  J. Monserrat,et al.  An automatic wash method for dimethyl sulfoxide removal in autologous hematopoietic stem cell transplantation decreases the adverse effects related to infusion , 2012, Transfusion.

[9]  A. Cometa,et al.  Automated washing of human progenitor cells: evaluation of apoptosis and cell necrosis , 2011, Transfusion medicine.

[10]  H. Yasuda,et al.  CD34+ cell enumeration by flow cytometry: a comparison of systems and methodologies. , 2011, Archives of pathology & laboratory medicine.

[11]  B. Esterni,et al.  Occurrence and severity of adverse events after autologous hematopoietic progenitor cell infusion are related to the amount of granulocytes in the apheresis product , 2007, Transfusion.

[12]  G. Milone,et al.  Adverse events after infusions of cryopreserved hematopoietic stem cells depend on non-mononuclear cells in the infused suspension and patient age. , 2007, Cytotherapy.

[13]  Luciano Rodríguez,et al.  Evaluation of an automated cell processing device to reduce the dimethyl sulfoxide from hematopoietic grafts after thawing , 2005, Transfusion.

[14]  R. Bouabdallah,et al.  Clinical experience with the delivery of thawed and washed autologous blood cells, with an automated closed fluid management device: CytoMate , 2005, Transfusion.

[15]  D. Kadidlo,et al.  Patient care during infusion of hematopoietic progenitor cells , 2004, Transfusion.

[16]  F. Sousa,et al.  Single- versus dual-platform assays for human CD34+ cell enumeration. , 1999, Cytometry.

[17]  S. Heimfeld,et al.  Severe central nervous system toxicity associated with the infusion of cryopreserved PBSC components. , 1999, Cytotherapy.

[18]  S. Heimfeld,et al.  Post-thaw removal of DMSO does not completely abrogate infusional toxicity or the need for pre-infusion histamine blockade. , 1999, Cytotherapy.

[19]  C. Le Forestier,et al.  A simple, efficient washing procedure for cryopreserved human hematopoietic stem cells prior to reinfusion. , 1991, Bone marrow transplantation.