A compact position-sensitive detector for PET

A high resolution BGO block detector has been developed for a positron emission tomography (PET) system. The detector consists of a newly developed compact position-sensitive photomultiplier tube (PS-PMT) and an 8(X)/spl times/4(Y) BGO array of which element size is 2.8 mm/spl times/6.8 mm/spl times/30 mm. The PS-PMT has ten stages of metal channel dynodes and crossed-wire anodes in a 28 mm square/spl times/20 mm high metal package. The performance of the PS-PMT and the block detector was evaluated in terms of applicability to PET. The coincidence timing resolution was 4.4 ns FWHM and 9.5 ns FWTM, and the energy resolution was about 30% for 511 keV /spl gamma/-rays, with the PS-PMTs coupled to single BGO segments. The spatial resolution of the block detector was evaluated by measuring the detector response functions (DRFs) for each BGO segment. The average FWHM values of the DRFs were 3.0 mm in the X direction, and 6.8 mm in the Y direction. Count rate performance of the block detector was measured at different activity levels, when no distinct mispositioning in crystal coding was seen at count rates up to 100 kcps. A compact SD-PET system dedicated to animal studies was designed by adopting the position-sensitive detectors. >

[1]  R. Nutt,et al.  A Multicrystal Two Dimensional BGO Detector System for Positron Emission Tomography , 1986, IEEE Transactions on Nuclear Science.

[2]  W. W. Moses,et al.  A positron tomograph with 600 BGO crystals and 2.6 mm resolution , 1988 .

[3]  Roger Lecomte,et al.  Design and engineering aspects of a high resolution positron tomograph for small animal imaging , 1994 .

[4]  M. Defrise,et al.  Three dimensional reconstruction of PET data from a multi-ring camera , 1989 .

[5]  K. Shimizu,et al.  High resolution block detectors for PET , 1990 .

[6]  James G. Colsher,et al.  Use of Position Sensitive Detectors in Positron Imaging , 1980, IEEE Transactions on Nuclear Science.

[7]  S. Suzuki,et al.  Photomultiplier tube of new dynode configuration , 1993 .

[8]  G Muehllehner,et al.  A positron camera using position-sensitive detectors: PENN-PET. , 1986, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[9]  T. Yamashita,et al.  A high resolution PET for animal studies , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[10]  M. Bergstrom,et al.  Design Studtes of Two Possible Detector Blocks for High Resolution Positron Emission Tomography of the Brain , 1987, IEEE Transactions on Nuclear Science.

[11]  K Wienhard,et al.  The ECAT EXACT HR: Performance of a New High Resolution Positron Scanner , 1994, Journal of computer assisted tomography.

[12]  R. Lecomte,et al.  Geometry Study of a High Resolution PET Detection System Using Small Detectors , 1984, IEEE Transactions on Nuclear Science.

[13]  M. Endo,et al.  Development of a high resolution PET , 1990 .

[14]  S R Cherry,et al.  3D PET using a conventional multislice tomograph without septa. , 1991, Journal of computer assisted tomography.

[15]  T G Turkington,et al.  Performance characteristics of a whole-body PET scanner. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.