The Italian subcutaneous implantable cardioverter-defibrillator survey: S-ICD, why not?

Abstract Aims A recommendation for a subcutaneous-implantable cardioverter-defibrillator (S-ICD) has been added to recent European Society of Cardiology Guidelines. However, the S-ICD is not ideally suitable for patients who need pacing. The aim of this survey was to analyse the current practice of ICD implantation and to evaluate the actual suitability of S-ICD. Methods and results The survey ‘S-ICD Why Not?’ was an independent initiative taken by the Italian Heart Rhythm Society (AIAC). Clinical characteristics, selection criteria, and factors guiding the choice of ICD type were collected in consecutive patients who underwent ICD implantation in 33 Italian centres from September to December 2015. A cardiac resynchronization therapy (CRT) device was implanted in 39% (369 of 947) of patients undergoing de novo ICD implantation. An S-ICD was implanted in 12% of patients with no CRT indication (62 of 510 with available data). S-ICD patients were younger than patients who received transvenous ICD, more often had channelopathies, and more frequently received their device for secondary prevention of sudden death. More frequently, the clinical reason for preferring a transvenous ICD over an S-ICD was the need for pacing (45%) or for antitachycardia pacing (36%). Nonetheless, only 7% of patients fulfilled conditions for recommending permanent pacing, and 4% of patients had a history of monomorphic ventricular tachycardia that might have been treatable with antitachycardia pacing. Conclusion The vast majority of patients needing ICD therapy are suitable candidates for S-ICD implantation. Nevertheless, it currently seems to be preferentially adopted for secondary prevention of sudden death in young patients with channelopathies.

[1]  Jagmeet P. Singh,et al.  2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[2]  Andrea Mazzanti,et al.  2015 ESC Guidelines for the Management of Patients With Ventricular Arrhythmias and the Prevention of Sudden Cardiac Death. , 2016, Revista espanola de cardiologia.

[3]  Paul A. Belk,et al.  Severe Atrioventricular Decoupling, Uncoupling, and Ventriculoatrial Coupling During Enhanced Atrial Pacing: Incidence, Mechanisms, and Implications for Minimizing Right Ventricular Pacing in ICD Patients , 2008, Journal of cardiovascular electrophysiology.

[4]  I. Ranasinghe,et al.  Long-Term Risk for Device-Related Complications and Reoperations After Implantable Cardioverter-Defibrillator Implantation , 2016, Annals of Internal Medicine.

[5]  Arjun D. Sharma,et al.  Percent right ventricular pacing predicts outcomes in the DAVID trial. , 2005, Heart rhythm.

[6]  W. Stevenson,et al.  Catheter ablation of ventricular tachycardia in ischaemic and non-ischaemic cardiomyopathy: where are we today? A clinical review. , 2012, European heart journal.

[7]  Pier D. Lambiase,et al.  Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator: 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry. , 2015, Journal of the American College of Cardiology.

[8]  H. Putter,et al.  Suitability for subcutaneous defibrillator implantation: results based on data from routine clinical practice , 2013, Heart.

[9]  Lluís Mont,et al.  2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). , 2013, European heart journal.

[10]  A. Auricchio,et al.  Extended detection time to reduce shocks is safe in secondary prevention patients: The secondary prevention substudy of PainFree SST. , 2016, Heart rhythm.

[11]  Wojciech Zareba,et al.  Reduction in inappropriate therapy and mortality through ICD programming. , 2012, The New England journal of medicine.

[12]  J. Day,et al.  Is Dual-Chamber Programming Inferior to Single-Chamber Programming in an Implantable Cardioverter-Defibrillator?: Results of the INTRINSIC RV (Inhibition of Unnecessary RV Pacing With AVSH in ICDs) Study , 2006, Circulation.

[13]  A. Wilde,et al.  Communicating Antitachycardia Pacing-Enabled Leadless Pacemaker and Subcutaneous Implantable Defibrillator. , 2016, Journal of the American College of Cardiology.

[14]  Mark Kremers,et al.  Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator , 2013, Circulation.

[15]  G. Boriani,et al.  [The Pacemaker and Implantable Cardioverter-Defibrillator Registry of the Italian Association of Arrhythmology and Cardiac Pacing - Annual report 2016]. , 2018, Giornale italiano di cardiologia.

[16]  L. Jordaens,et al.  Rationale and design of the PRAETORIAN trial: a Prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy. , 2012, American heart journal.

[17]  P. Lambiase,et al.  Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry , 2014, European heart journal.

[18]  M. Chung,et al.  Complication Rates Associated With Pacemaker or Implantable Cardioverter-Defibrillator Generator Replacements and Upgrade Procedures: Results From the REPLACE Registry , 2010, Circulation.

[19]  Eugene Crystal,et al.  Evaluation of early complications related to De Novo cardioverter defibrillator implantation insights from the Ontario ICD database. , 2010, Journal of the American College of Cardiology.

[20]  N. Hawkins,et al.  How many patients fulfil the surface electrocardiogram criteria for subcutaneous implantable cardioverter-defibrillator implantation? , 2014, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[21]  J. Nielsen,et al.  ESC Guidelines on cardiac pacing and cardiac resynchronization therapy , 2014 .

[22]  S. Boveda,et al.  Implantation of subcutaneous implantable cardioverter defibrillators in Europe: results of the European Heart Rhythm Association survey. , 2016, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.

[23]  J. Healey,et al.  Wilkoff BL, et al. 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement on optimal implantable cardioverter-defibrillator programming and testing. , 2017, Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology.