Influence of HVDC Ground Electrode Current on AC Transmission System and Its Restraining Measure

HVDC power systems operating in ground-return mode produce DC voltages around the electrodes. During Monopolar operations of the HVDC electrode, DC biases of the transformers caused by the DC current through neutral points may damage the transformers and the whole network. The noises and the neutral point DC currents of the main transformers with earthed neutral points in Yihe substation and LN power plant were measured and recorded during the commissioning of the HVDC system from Three Gorges power station to Guangdong power network. Compared to injecting reverse direct current and inserting in series with the neutral point an appropriate resistance, the strategy of installing capacitors to the main transformer neutral point is more effective. According to the DC current values measured at the transformer neutrals of LN power station, this method was studied based on its corresponding module of power system with ground grid proposed. Simulations have been carried out and some main technology parameters were put forward according to the research results.

[1]  Cheng Cixuan Simulating Analysis of Exciting Current of Single Phase Transformer on DC Bias , 2005 .

[2]  L. Bolduc,et al.  Development of a DC current-blocking device for transformer neutrals , 2005, IEEE Transactions on Power Delivery.

[3]  Wan Da,et al.  Application of bias-resisting reverse DC injection at neutral point of transformers , 2005 .

[4]  Wu Xiao-chen ANALYSIS ON OPERATIONAL PROBLEMS IN SOUTH CHINA AC-DC HYBRID POWER GRID , 2004 .

[5]  Zhang Bo Study on the Impact of HVDC Ground Return Current on AC System and Resolutions , 2005 .

[6]  Mei Guihua,et al.  Influence of DC transmission on transformers in AC system , 2006 .

[7]  P.G. McLaren,et al.  Modeling GIC effects on power systems: the need to model magnetic status of transformers , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[8]  Li Xiao-lin,et al.  Network algorithm to analyze effects of DC transmission ground current on AC system , 2005 .

[9]  D. Boteler,et al.  A study of geoelectromagnetic disturbances in Quebec. I. General results , 1998 .

[10]  Xu Ming-rong Optimized Grounding Resistance Configuration against DC Magnetic Bias of Large Capacity Power Transformer , 2006 .

[11]  Ma Zhi-qiang Simulation of transformer DC magnetic biasing , 2004 .

[12]  Hu Zhao-qing DECENTRALIZED COORDINATED CONTROL OF THE AC/DC HYBRID TRANSMISSION SYSTEM , 2005 .

[13]  D. Boteler,et al.  A study of geoelectromagnetic disturbances in Quebec. II. Detailed analysis of a large event , 2000 .

[14]  Zhu Yi-ying,et al.  Studying on Measures of Restraining DC Current through Transformer Neutrals , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[15]  L. Bolduc,et al.  Development of a DC current-blocking device for transformer neutrals , 2005 .

[16]  Zhang Qiang ANALYSIS ON INFLUENCE OF GROUND ELECTRODE CURRENT IN HVDC ON AC POWER NETWORK , 2005 .

[17]  P. R. Price,et al.  Geomagnetically Induced Current Effects on Transformers , 2002, IEEE Power Engineering Review.