Fuzzy multivariable control of domestic heat pumps

Poor control has been identified as one of the reasons why recent field trials of domestic heat pumps in the UK have produced disappointing results. Most of the technology in use today uses a thermostatically-controlled fixed speed compressor with a mechanical expansion device. This article investigates improved control of these heat pumps through the design and evaluation of a new multivariable fuzzy logic control system utilising a variable speed compressor drive with capacity control linked through to evaporator superheat control. A new dynamic thermal model of a domestic heat pump validated using experimental data forms the basis of the work. The proposed control system is evaluated using median and extreme daily heating demand profiles for a typical UK house compared with a basic thermostatically-controlled alternative. Results show good tracking of the heating temperature and superheat control variables, reduced cycling and an improvement in performance averaging 20%.

[1]  K. S. Lee,et al.  Experiments on the characteristics of evaporation of R410A in brazed plate heat exchangers with different geometric configurations , 2003 .

[2]  Davide Del Col,et al.  Energy efficiency in a ground source heat pump with variable speed drives , 2015 .

[3]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 8.0 , 2007 .

[4]  Orhan Ekren,et al.  Comparison of different controllers for variable speed compressor and electronic expansion valve , 2010 .

[5]  E. W. Grald,et al.  Prediction of cyclic heat pump performance with a fully distributed model and a comparison with experimental data , 1987 .

[6]  Jingyi Wu,et al.  Research on the control laws of the electronic expansion valve for an air source heat pump water hea , 2011 .

[7]  Ciro Aprea,et al.  Fuzzy control of the compressor speed in a refrigeration plant , 2004 .

[8]  C. P. Gleeson,et al.  Meta-analysis of European heat pump field trial efficiencies , 2013 .

[9]  Savvas A. Tassou,et al.  VARIABLE-SPEED CAPACITY CONTROL IN REFRIGERATION SYSTEMS , 1996 .

[10]  C. K. Rice The effect of void fraction correlation and heat flux assumption on refrigerant charge inventory predictions , 1987 .

[11]  Chris Underwood On the Design and Response of Domestic Ground-Source Heat Pumps in the UK , 2014 .

[12]  S. Patankar Numerical Heat Transfer and Fluid Flow , 2018, Lecture Notes in Mechanical Engineering.

[13]  C. K. Lee,et al.  Dynamic performance of ground-source heat pumps fitted with frequency inverters for part-load control , 2010 .

[14]  K. S. Lee,et al.  The characteristics of condensation in brazed plate heat exchangers with different chevron angles , 2003 .

[15]  Per Fahlén,et al.  Capacity-controlled ground source heat pumps in hydronic heating systems , 2007 .

[16]  Wenhua Li,et al.  Simplified steady-state modeling for variable speed compressor , 2013 .

[17]  Rita Mastrullo,et al.  Experimental analysis of the scroll compressor performances varying its speed , 2006 .