Fiber-amplifier-enhanced resonant photoacoustic sensor for sub-ppb level acetylene detection

Abstract A near-infrared fiber-amplifier-enhanced resonant photoacoustic spectroscopy (PAS) sensor is developed for sub-ppb level acetylene (C2H2) detection. The photoacoustic excitation source is composed of a telecommunication distributed feedback (DFB) laser and an erbium-doped fiber amplifier (EDFA). The weak photoacoustic second-harmonic signal is demodulated by a field-programmable gate array (FPGA) based lock-in amplifier. For sensitivity improvement, wavelength modulation spectrum and wavelet denoising methods are employed. The PAS sensor is optimized in terms of resonant frequency and current modulation depth for C2H2 detection at the wavelength of 1532.83 nm. The linearity of the sensor response to the laser power and C2H2 concentration confirms that saturation does not occur with the excitation power less than 1 W. With 1 W excitation power and 60 s averaging time, the detection limit (1δ) is achieved to be 0.37 ppb, which is the best value compared with other photoacoustic C2H2 sensors ever reported so far.

[1]  D. C. Dumitras,et al.  Laser photoacoustic spectroscopy: principles, instrumentation, and characterization , 2007 .

[2]  V. Koskinen,et al.  Progress in cantilever enhanced photoacoustic spectroscopy , 2008 .

[3]  Martin Vetterli,et al.  Adaptive wavelet thresholding for image denoising and compression , 2000, IEEE Trans. Image Process..

[4]  Jun Chang,et al.  Fiber-ring laser-based intracavity photoacoustic spectroscopy for trace gas sensing. , 2017, Optics letters.

[5]  Jeena Joy,et al.  DENOISING USING SOFT THRESHOLDING , 2013 .

[6]  Gang Li,et al.  The HITRAN 2008 molecular spectroscopic database , 2005 .

[7]  A. Miklós,et al.  Application of acoustic resonators in photoacoustic trace gas analysis and metrology , 2001 .

[8]  Huadan Zheng,et al.  Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring , 2017, Nature Communications.

[9]  Frank K. Tittel,et al.  Quartz-Enhanced Photoacoustic Spectroscopy: A Review , 2014, Sensors.

[10]  Frank-Michael Matysik,et al.  Low-cost photoacoustic NO2 trace gas monitoring at the pptV-level , 2017 .

[11]  A. Dudzinska Investigation of adsorption and desorption of acetylene on hard coal samples from Polish mines , 2014 .

[12]  M. Hippler,et al.  Cavity-enhanced resonant photoacoustic spectroscopy with optical feedback cw diode lasers: A novel technique for ultratrace gas analysis and high-resolution spectroscopy. , 2010, The Journal of chemical physics.

[13]  Hao Wu,et al.  Tracing Acetylene Dissolved in Transformer Oil by Tunable Diode Laser Absorption Spectrum , 2017, IEEE Transactions on Dielectrics and Electrical Insulation.

[14]  D. Iannuzzi,et al.  Demonstration of a highly sensitive photoacoustic spectrometer based on a miniaturized all-optical detecting sensor. , 2017, Optics express.

[15]  B. Lendl,et al.  Cantilever-enhanced photoacoustic detection of hydrogen sulfide (H2S) using NIR telecom laser sources near 1.6 µm , 2016, Applied Physics B.

[16]  Ke Chen,et al.  High-sensitivity fiber-optic acoustic sensor for photoacoustic spectroscopy based traces gas detection , 2017 .

[17]  Weijun Zhang,et al.  Multi-resonator photoacoustic spectroscopy , 2017 .

[18]  Markus W. Sigrist,et al.  Longitudinal resonant spectrophone for CO-laser photoacoustic spectroscopy , 1987 .

[19]  S. Schilt,et al.  Wavelength modulation photoacoustic spectroscopy: Theoretical description and experimental results , 2006 .

[20]  F. Matysik,et al.  Development and characterization of a laboratory setup for photoacoustic NO 2 determination based on the excitation of electronic 2 B 2 and 2 B 1 states using a low-cost semiconductor laser , 2017 .

[21]  Jianwei Wang,et al.  Near-IR tunable laser based photoacoustic sensor for sub-ppb C2H2 detections , 2015 .

[22]  Li Fang,et al.  Resonant photoacoustic detection of trace gas with DFB diode laser , 2007 .

[23]  Jari Peltola,et al.  Parts-per-trillion-level detection of nitrogen dioxide by cantilever-enhanced photo-acoustic spectroscopy. , 2015, Optics letters.

[24]  Peter Hess,et al.  Resonant photoacoustic spectroscopy , 1983 .

[25]  Frank K. Tittel,et al.  Ultra-high sensitive acetylene detection using quartz-enhanced photoacoustic spectroscopy with a fiber amplified diode laser and a 30.72 kHz quartz tuning fork , 2017 .