Edge termination impact on clamped inductive turn-off failure in high-voltage IGBTs under overcurrent conditions

This work provides a physical insight into the failure of high-voltage IGBT modules for railway traction when an overload current event occurs during a clamped inductive turn-off. The inspection of failed IGBTs in power modules coming from the field reveals burnt-out points in the vicinity of the device edge termination. This physical signature has been also verified by experimental tests. To explore this result, physical TCAD simulations have been carried out considering, for the first time, the electro-thermal mismatch introduced by the edge termination. From simulation and experimental results, a destructive dynamic avalanche phenomenon at the last IGBT cell is identified as responsible for the observed failure.

[1]  Steven T. Peake,et al.  Power semiconductor devices , 1995 .

[2]  Josef Lutz,et al.  Dynamic avalanche and reliability of high voltage diodes , 2003, Microelectron. Reliab..

[3]  B. J. Baliga,et al.  Trends in power semiconductor devices , 1996 .

[4]  J.-L. Schanen,et al.  Use of Accurate Chip Level Modeling and Analysis of a Power Module to establish Reliability Rules , 2006, 2006 IEEE International Symposium on Industrial Electronics.

[5]  J. Rebollo,et al.  Analysis of Clamped Inductive Turnoff Failure in Railway Traction IGBT Power Modules Under Overload Conditions , 2011, IEEE Transactions on Industrial Electronics.

[6]  Kazunari Hatade,et al.  Advanced RFC technology with new cathode structure of field limiting rings for High Voltage planar diode , 2010, 2010 22nd International Symposium on Power Semiconductor Devices & IC's (ISPSD).

[7]  U. Schlapbach,et al.  Limitation of the short-circuit ruggedness of high-voltage IGBTs , 2009, 2009 21st International Symposium on Power Semiconductor Devices & IC's.

[8]  Katsuhiko Nishiwaki,et al.  Investigations of inhomogeneous operation of IGB under Unclamped Inductive Switching condition , 2010, 2010 22nd International Symposium on Power Semiconductor Devices & IC's (ISPSD).

[9]  Mauro Ciappa,et al.  Selected failure mechanisms of modern power modules , 2002, Microelectron. Reliab..

[10]  Munaf Rahimo,et al.  Freewheeling diode reverse-recovery failure modes in IGBT applications , 2001 .

[11]  T. Puritis,et al.  Problems Related to Avalanche and Secondary Breakdown of Silicon p-n Junction , 1995, ESSDERC '95: Proceedings of the 25th European Solid State Device Research Conference.

[12]  Michel Mermet-Guyennet,et al.  IGBT module failure analysis in railway applications , 2008, Microelectron. Reliab..

[13]  Wolfgang Fichtner,et al.  Compact modelling and analysis of power-sharing unbalances in IGBT-modules used in traction applications , 2006, Microelectron. Reliab..

[14]  G. Wachutka,et al.  Time-Periodic Avalanche Breakdown at the Edge Termination of Power Devices , 2008, 2008 20th International Symposium on Power Semiconductor Devices and IC's.

[15]  K. Nishiwaki,et al.  Investigation of Dynamic Avalanche in the Termination Region for FWDs with High Reverse Recovery Capability , 2008, 2008 20th International Symposium on Power Semiconductor Devices and IC's.

[16]  Frank Pfirsch,et al.  Investigations on the stability of dynamic avalanche in IGBTs , 2002, Proceedings of the 14th International Symposium on Power Semiconductor Devices and Ics.

[17]  V. d'Alessandro,et al.  Analytical model for thermal instability of low voltage power MOS and SOA in pulse operation , 2002, Proceedings of the 14th International Symposium on Power Semiconductor Devices and Ics.