Electrical impedance tomography to confirm correct placement of double-lumen tube: a feasibility study.

BACKGROUND Double-lumen tubes (DLTs) are frequently used to establish one-lung ventilation (OLV). Their correct placement is crucial. We hypothesized that electrical impedance tomography (EIT) reliably displays distribution of ventilation between left and right lung and may thus be used to verify correct DLT placement online. METHODS Regional ventilation was studied by EIT in 40 patients requiring insertion of left-sided DLTs for OLV during thoracic surgery. EIT was recorded during two-lung ventilation before induction of anaesthesia and after DLT placement, and during OLV in the supine and subsequently in the lateral position. EIT measurements were made before and after verification of correct DLT placement by fibreoptic bronchoscopy (FOB). RESULTS EIT accurately displayed distribution of ventilation between left and right lung online. All cases (n=5) of initially misplaced DLTs in the contralateral right main bronchus were detected by EIT. However, EIT did not allow prediction of FOB-detected endobronchial cuff misplacement requiring DLT repositioning. Furthermore, after DLT repositioning, distribution of ventilation, as assessed by EIT, did not change significantly (all P>0.5). CONCLUSIONS This study demonstrates that EIT enables accurate display of left and right lung ventilation and, thus, non-invasive online recognition of misplacement of left-sided DLTs in the contralateral main bronchus. However, as distribution of ventilation did not correlate with endobronchial cuff placement, EIT cannot replace FOB in the routine control of DLT position.

[1]  End-tidal CO2 analyzers in proper positioning of the double-lumen tubes. , 1986, Anesthesiology.

[2]  J. Benumof Anesthesia for thoracic surgery , 1987 .

[3]  E. Cohen,et al.  Intraoperative manipulation for positioning of double-lumen tubes. , 1988, Anesthesiology.

[4]  H. Moseley,et al.  Dual end-tidal CO2 monitoring and double-lumen tubes , 1992, Canadian journal of anaesthesia = Journal canadien d'anesthesie.

[5]  B. Simon,et al.  An aid in the diagnosis of malpositioned double-lumen tubes. , 1992, Anesthesiology.

[6]  J. Benumof The position of a double-lumen tube should be routinely determined by fiberoptic bronchoscopy. , 1993, Journal of cardiothoracic and vascular anesthesia.

[7]  W. J. Russell,et al.  Problems Related to the Endotracheal Tube: An Analysis of 2000 Incident Reports , 1993, Anaesthesia and intensive care.

[8]  P. Myles,et al.  Analysis of demographic characteristics. , 1994, Anaesthesia and intensive care.

[9]  A. Macario,et al.  Tracheal Diameter Predicts Double-Lumen Tube Size: A Method for Selecting Left Double-Lumen Tubes , 1996, Anesthesia and analgesia.

[10]  F. Cunningham,et al.  Anesthesiology and Critical Care Drug Handbook , 1997 .

[11]  G Hahn,et al.  Monitoring perioperative changes in distribution of pulmonary ventilation by functional electrical impedance tomography , 1998, Acta anaesthesiologica Scandinavica.

[12]  W. Karzai,et al.  Role of Fiberoptic Bronchoscopy in Conjunction with the Use of Double‐lumen Tubes for Thoracic Anesthesia: A Prospective Study , 1998, Anesthesiology.

[13]  B H Brown,et al.  Electrical impedance tomography (EIT): a review , 2003, Journal of medical engineering & technology.

[14]  H. Lemmens,et al.  Left double-lumen tubes: clinical experience with 1,170 patients. , 2003, Journal of cardiothoracic and vascular anesthesia.

[15]  E. Cohen Double-lumen tube position should be confirmed by fiberoptic bronchoscopy , 2004, Current opinion in anaesthesiology.

[16]  K. Kitaguchi,et al.  Double lumen tube location predicts tube malposition and hypoxaemia during one lung ventilation. , 2004, British journal of anaesthesia.

[17]  Gerhard Hellige,et al.  Distribution of ventilation in young and elderly adults determined by electrical impedance tomography , 2004, Respiratory Physiology & Neurobiology.

[18]  Harki Tanaka,et al.  Imbalances in regional lung ventilation: a validation study on electrical impedance tomography. , 2004, American journal of respiratory and critical care medicine.

[19]  K. Weng,et al.  Secondary confirmation of endotracheal tube position by ultrasound image , 2004, Critical care medicine.

[20]  Ronald D. Miller Miller's Anesthesia , 2005 .

[21]  V. Baum Auscultation of Bilateral Breath Sounds Does Not Rule Out Endobronchial Intubation in Children , 2005 .

[22]  K. Kernstine,et al.  Devices for Lung Isolation Used by Anesthesiologists with Limited Thoracic Experience: Comparison of Double-lumen Endotracheal Tube, Univent® Torque Control Blocker, and Arndt Wire-guided Endobronchial Blocker® , 2006, Anesthesiology.

[23]  S. Lundin,et al.  Positive end‐expiratory pressure optimization using electric impedance tomography in morbidly obese patients during laparoscopic gastric bypass surgery , 2006, Acta anaesthesiologica Scandinavica.

[24]  Ola Stenqvist,et al.  Regional lung derecruitment after endotracheal suction during volume- or pressure-controlled ventilation: a study using electric impedance tomography , 2006, Intensive Care Medicine.

[25]  D. Lederman,et al.  Acoustic Monitoring of Double-Lumen Ventilated Lungs for the Detection of Selective Unilateral Lung Ventilation , 2006, Anesthesia and analgesia.

[26]  S. Leonhardt,et al.  Electrical impedance tomography: changes in distribution of pulmonary ventilation during laparoscopic surgery in a porcine model , 2006, Langenbeck's Archives of Surgery.

[27]  Christian Putensen,et al.  Electrical impedance tomography guided ventilation therapy , 2007, Current opinion in critical care.