Three methods for measuring range of motion while wearing protective clothing: A comparative study

This paper evaluates three methods for objectively measuring ROM while workers are wearing protective clothing: a universal goniometer, a Leighton Flexometer, and an electrogoniometer. Ten male subjects performed a set of nine gross body movements while semi-nude and while wearing each of nine configurations of coveralls. Coveralls varied in relative size and fabric weight, Changes in joint angles were measured simultaneously with the goniometer and the electrogoniometer, and then simultaneously with the Flexometer and the electrogoniometer. The goniometer and Flexometer data were positively correlated across garment treatments, but the electrogoniometer data were not highly correlated with either the goniometer or Flexometer data. Precision was similar between the goniometer and Flexometer, but the goniometer was found to be much less invasive than the Flexometer.

[1]  Paul Stuart Adams The effects of protective clothing on worker performance: A study of size and fabric weight effects on range-of-motion. , 1993 .

[2]  Wm. Kirk,et al.  Fundamental Relationship of Fabric Extensibility to Anthropometric Requirements and Garment Performance , 1966 .

[3]  Carolyn K Bensel,et al.  The Effects of US Army Chemical Protective Clothing on Speech Intelligibility, Visual Field, Body Mobility and Psychomotor Coordination of Men , 1987 .

[4]  J Huck,et al.  Restriction to movement in fire-fighter protective clothing: evaluation of alternative sleeves and liners. , 1991, Applied ergonomics.

[5]  D. Burdon,et al.  Clinical methods of goniometry: a comparative study. , 1992, Disability and rehabilitation.

[6]  Lloyd L. Laubach,et al.  The Effects of Personal Protective Equipment Upon the Arm-Reach Capability of USAF Pilots , 1973 .

[7]  S. Abraham,et al.  Weight and height of adults 18-74 years of age. United States, 1971-74. , 1979, Vital and health statistics. Series 11, Data from the National Health Survey.

[8]  A. J. Bachrach,et al.  Human Engineering Considerations in the Evaluation of Diving Equipment , 1976 .

[9]  R. Gregory,et al.  HUMAN PERCEPTION. , 1964, British medical bulletin.

[10]  Norman R. S. Hollies,et al.  A Human Perception Analysis Approach to Clothing Comfort , 1979 .

[11]  J. M. Rothstein,et al.  Goniometric Reliability in a Clinical Setting , 1983 .

[12]  W. Rheault,et al.  Concurrent validity and intertester reliability of universal and fluid-based goniometers for active elbow range of motion. , 1988, Physical therapy.

[13]  Jh Veghte The Physiologic Strain Imposed by Wearing Fully Encapsulated Chemical Protective Clothing , 1989 .

[14]  Mayerson Nh,et al.  Goniometric measurement reliability in physical medicine. , 1984 .

[15]  J Huck,et al.  Protective clothing systems: A technique for evaluating restriction of wearer mobility. , 1988, Applied ergonomics.

[16]  Ronald J. Spicuzza,et al.  An Automated Methodology for Conducting Human Factors Evaluations of Protective Garments , 1985 .

[17]  J Faff,et al.  Physiological responses to working with fire fighting equipment in the heat in relation to subjective fatigue. , 1989, Ergonomics.

[18]  S. Azen,et al.  Reliability of goniometric measurements. , 1978, Physical therapy.

[19]  F Gamberale,et al.  The perception of exertion. , 1985, Ergonomics.

[20]  M. E. Maxfield,et al.  Abbreviated Methods for the Measurement of Oxygen Consumption in Work Physiology , 1967 .

[21]  John A. Morrissey,et al.  Maintenance Operations in Mission Oriented Protective Posture Level IV (MOPPIV). Part 2 , 1987 .