Elastic matching of dynamic MR mammographic images

Dynamic magnetic resonance imaging (MRI) carried out with paramagnetic contrast media has been proven to increase sensitivity and specificity in the detection of breast cancer. Due to movements of the patients and changes in the shape of the breasts during the measurement period, a coregistration (matching) of the acquired data volumes is necessary to obtain higher accuracy for the localization of lesions. In this study, an algorithm for the elastic matching of dynamic MRI volume data is presented. The approach includes automatic feature extraction along with the analysis of corresponding features between the data sets. The matching is actually slice‐oriented, even though information on displacement vectors in adjacent slices is taken into account. An extension of the procedure to fully three‐dimensionally (3D) matching is straight forward. Up until now, the approach has been applied to 20 dynamic MRI studies. The matching time for two image data sets with 256 × 256 × 15 voxels each was about 4 min using a PC (Pentium Pro, 200MHz). Magn Reson Med 43:9–16, 2000. © 2000 Wiley‐Liss, Inc.

[1]  S E Harms,et al.  Integration of breast magnetic resonance imaging with breast cancer treatment. , 1998, Topics in magnetic resonance imaging : TMRI.

[2]  F. Meyer Iterative image transformations for an automatic screening of cervical smears. , 1979, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[3]  L J van Erning,et al.  MR characterization of suspicious breast lesions with a gadolinium-enhanced TurboFLASH subtraction technique. , 1994, Radiology.

[4]  David J. Burr,et al.  Elastic Matching of Line Drawings , 1981, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[5]  A Heinig,et al.  Contrast-enhanced MRI of the breast: accuracy, value, controversies, solutions. , 1997, European journal of radiology.

[6]  Anil K. Jain,et al.  Object Matching Using Deformable Templates , 1996, IEEE Trans. Pattern Anal. Mach. Intell..

[7]  Jean-Philippe Thirion,et al.  Fast Non-Rigid Matching of 3D Medical Images , 1995 .

[8]  Ruzena Bajcsy,et al.  Multiresolution elastic matching , 1989, Comput. Vis. Graph. Image Process..

[9]  P. Ercolani,et al.  Dynamic MRI of the breast. , 1998, European journal of radiology.

[10]  W. J. Lorenz,et al.  Pharmacokinetic Mapping of the Breast: A New Method for Dynamic MR Mammography , 1995, Magnetic resonance in medicine.

[11]  S E Harms,et al.  Breast magnetic resonance imaging. , 1998, Seminars in ultrasound, CT, and MR.

[12]  P. L. Davis,et al.  Sensitivity of enhanced MRI for the detection of breast cancer: new, multicentric, residual, and recurrent , 1997, European Radiology.

[13]  M. Friedrich,et al.  MRI of the breast: state of the art , 1998, European Radiology.

[14]  G Brix,et al.  MR mammography with pharmacokinetic mapping for monitoring of breast cancer treatment during neoadjuvant therapy. , 1994, Magnetic resonance imaging clinics of North America.

[15]  Jürgen Weese,et al.  Point-Based Elastic Registration of Medical Image Data Using Approximating Thin-Plate Splines , 1996, VBC.

[16]  M D Schnall,et al.  Future directions in imaging of breast diseases. , 1998, Radiology.

[17]  C. Piccoli,et al.  Contrast-enhanced breast MRI: factors affecting sensitivity and specificity , 1997, European Radiology.

[18]  Fred L. Bookstein,et al.  Principal Warps: Thin-Plate Splines and the Decomposition of Deformations , 1989, IEEE Trans. Pattern Anal. Mach. Intell..

[19]  L R Schad,et al.  Pharmacokinetic parameters in CNS Gd-DTPA enhanced MR imaging. , 1991, Journal of computer assisted tomography.

[20]  P. Viehweg,et al.  Sensitivity of contrast-enhanced MR imaging of the breast. , 1994, Magnetic resonance imaging clinics of North America.