Initial Experience With the Development and Numerical and In Vitro Studies of A Novel Low-Pressure Artificial Right Ventricle for Pediatric Fontan Patients

The Fontan operation, an efficient palliative surgery, is performed for patients with single-ventricle pathologies. The total cavopulmonary connection is a preferred Fontan procedure in which the superior and inferior vena cava are connected to the left and right pulmonary artery. The overall goal of this work is to develop an artificial right ventricle that can be introduced into the inferior vena cava, which would act to reverse the deleterious hemodynamics in post-Fontan patients. We present the initial design and computational analysis of a micro-axial pump, designed with the particular hemodynamics of Fontan physiology in mind. Preliminary in vitro data on a prototype pump are also presented. Computational studies showed that the new design can deliver a variety of advantageous operating conditions, including decreased venous pressure through proximal suction, increased pressure rise across the pump, increased pulmonary flows, and minimal changes in superior vena cava pressures. In vitro studies on a scaled prototype showed trends similar to those seen computationally. We conclude that a micro-axial flow pump can be designed to operate efficiently within the low-pressure, low-flow environment of cavopulmonary flows. The results provide encouragement to pursue this design to for in vitro studies and animal studies.

[1]  E. Blackstone,et al.  Outcome after a "perfect" Fontan operation. , 1990, Circulation.

[2]  A. Untăroiu,et al.  Design and Transient Computational Fluid Dynamics Study of a Continuous Axial Flow Ventricular Assist Device , 2004, ASAIO journal.

[3]  Yanhang Zhang,et al.  Simulations of congenital septal defect closure and reactivity testing in patient-specific models of the pediatric pulmonary vasculature: A 3D numerical study with fluid-structure interaction. , 2006, Journal of biomechanical engineering.

[4]  S P Sutera,et al.  Deformation and fragmentation of human red blood cells in turbulent shear flow. , 1975, Biophysical journal.

[5]  James F. Antaki,et al.  Quantitative Evaluation of Blood Damage in a Centrifugal VAD by Computational Fluid Dynamics , 2004 .

[6]  R. Opitz,et al.  A Couette viscometer for short time shearing of blood. , 1980, Biorheology.

[7]  S P Sutera,et al.  HEMOLYSIS AND SUBHEMOLYTIC ALTERATIONS OF HUMAN RBC INDUCED BY TURBULENT SHEAR FLOW , 1972, Transactions - American Society for Artificial Internal Organs.

[8]  R Fumero,et al.  A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection. , 1996, Journal of biomechanics.

[9]  F. Migliavacca,et al.  Computational fluid dynamics simulations in realistic 3-D geometries of the total cavopulmonary anastomosis: the influence of the inferior caval anastomosis. , 2003, Journal of biomechanical engineering.

[10]  O. Reinhartz,et al.  Mechanical support of total cavopulmonary connection with an axial flow pump. , 2005, The Journal of thoracic and cardiovascular surgery.

[11]  Mark Fogel,et al.  In vitro flow analysis of a patient-specific intraatrial total cavopulmonary connection. , 2005, The Annals of thoracic surgery.

[12]  M. D. de Leval The Fontan Circulation: What Have We Learned? What to Expect? , 1998, Pediatric cardiology.

[13]  Y Miyazoe,et al.  Computational fluid dynamic analyses to establish design process of centrifugal blood pumps. , 1998, Artificial organs.

[14]  M. Leval,et al.  The Fontan Circulation: What Have We Learned? What to Expect? , 1998, Pediatric Cardiology.

[15]  J. Hertzberg,et al.  Effect of reverse flow on the fluid dynamics of the Total Cavo-pulmonary Connection: a potential cause of progressive heart failure , 2002 .

[16]  W. Jones,et al.  The prediction of laminarization with a two-equation model of turbulence , 1972 .

[17]  F. Migliavacca,et al.  Computational fluid dynamic study of flow optimization in realistic models of the total cavopulmonary connections. , 2004, The Journal of surgical research.

[18]  H. Reul,et al.  Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves , 1990, The International journal of artificial organs.

[19]  Alexey J. Stepanoff,et al.  Centrifugal and Axial Flow Pumps: Theory, Design, and Application , 1991 .

[20]  S. Mahalingam,et al.  An assessment of the major flow features that affect energy loss and potential for thrombus formation within the modified total cavo-pulmonary connection: computational and scaled in-vitro studies , 2002 .

[21]  John W. Brown,et al.  Cavopulmonary assist in the neonate: an alternative strategy for single-ventricle palliation. , 2004, The Journal of thoracic and cardiovascular surgery.

[22]  R. Kamm,et al.  A fluid--structure interaction finite element analysis of pulsatile blood flow through a compliant stenotic artery. , 1999, Journal of biomechanical engineering.

[23]  J D Hellums,et al.  Red blood cell damage by shear stress. , 1972, Biophysical journal.

[24]  A. Yoganathan,et al.  Toward designing the optimal total cavopulmonary connection: an in vitro study. , 1999, The Annals of thoracic surgery.

[25]  Irina Surovtsova,et al.  Effects of compliance mismatch on blood flow in an artery with endovascular prosthesis. , 2005, Journal of biomechanics.

[26]  Jack Rychik,et al.  Protein-losing enteropathy after Fontan operation. , 2007, Congenital heart disease.

[27]  D B Olsen,et al.  Design of a Continuous Flow Centrifugal Pediatric Ventricular Assist Device , 2003, The International journal of artificial organs.

[28]  F. Migliavacca,et al.  Computational fluid dynamics in the evaluation of hemodynamic performance of cavopulmonary connections after the Norwood procedure for hypoplastic left heart syndrome. , 2003, The Journal of thoracic and cardiovascular surgery.

[29]  R. Shandas,et al.  Effect of Vessel Size on the Flow Efficiency of the Total Cavopulmonary Connection: In Vitro Studies , 2002, Pediatric Cardiology.

[30]  A. Yoganathan,et al.  Flaring of the Vessels at the Total Cavopulmonary Connection (TCPC) Site Further Reduces Power Losses , 1998 .

[31]  H Reul,et al.  Assessment of hemolysis related quantities in a microaxial blood pump by computational fluid dynamics. , 2001, Artificial organs.

[32]  Robin Shandas,et al.  Comparison of In Vitro Velocity Measurements in a Scaled Total Cavopulmonary Connection with Computational Predictions , 2003, Annals of Biomedical Engineering.

[33]  Robin Shandas,et al.  Influence of connection geometry and SVC-IVC flow rate ratio on flow structures within the total cavopulmonary connection: a numerical study. , 2002, Journal of biomechanical engineering.

[34]  John W. Brown,et al.  Cavopulmonary assist: circulatory support for the univentricular Fontan circulation. , 2003, The Annals of thoracic surgery.

[35]  Don Olsen,et al.  Computational Fluid Dynamics (CFD) study of the 4th generation prototype of a continuous flow Ventricular Assist Device (VAD). , 2004, Journal of biomechanical engineering.

[36]  Robin Shandas,et al.  Insights into the effect of aortic compliance on Doppler diastolic flow patterns seen in coarctation of the aorta: a numeric study. , 2003, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[37]  Xinwei Song,et al.  Computational fluid dynamics prediction of blood damage in a centrifugal pump. , 2003, Artificial organs.

[38]  Robin Shandas,et al.  Computational simulations of the total cavo-pulmonary connection: insights in optimizing numerical solutions. , 2005, Medical engineering & physics.

[39]  Brian Launder,et al.  Prediction of Momentum, Heat and Mass Transfer in Swirling, Turbulent Boundary Layers , 1974 .