Biocompatibility tests on a novel glass-ceramic system.

The aim of this study was to look at the bone bonding potential of six formulations of a novel glass-ceramic system. Cylinders of the ceramics were implanted in rabbit tibiae for 4 and 7 weeks. Histological tests, both quantitative and qualitative, as well as push-out tests, were carried out during the bonding assessment. Bone growth was quite prolific, even at 4 weeks, as evidenced by growth up to and along the implant surfaces. The interfacial shear strengths compared well with other biomaterials in use as endosseous implants. Therefore it seems pertinent to pursue further long-term experimentation with this material.

[1]  J. M. Zhu,et al.  Effect of aluminum on bone matrix inductive properties. , 1990, Kidney international.

[2]  A. Boyde,et al.  Fluorescence in the tandem scanning microscope , 1990, Journal of microscopy.

[3]  R. Turner,et al.  The effects of fluoride on bone and implant histomorphometry in growing rats , 1989, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[4]  T. Yamamuro,et al.  Bone bonding behavior of MgO-CaO-SiO2-P2O5-CaF2 glass (mother glass of A.W-glass-ceramics). , 1989, Journal of biomedical materials research.

[5]  S D Cook,et al.  The effect of surface macrotexture and hydroxylapatite coating on the mechanical strengths and histologic profiles of titanium implant materials. , 1987, Journal of biomedical materials research.

[6]  C. Klein,et al.  Plasma sprayed coatings of hydroxylapatite. , 1987, Journal of biomedical materials research.

[7]  P. S. Rogers,et al.  Spherulitic growth of apatite in a glass—ceramic system , 1986 .

[8]  R. Pilliar,et al.  A Histological Assessment of the Initial Healing Response Adjacent to Porous-surfaced, Titanium Alloy Dental Implants in Dogs , 1986, Journal of dental research.

[9]  S D Cook,et al.  An evaluation of variables influencing implant fixation by direct bone apposition. , 1985, Journal of biomedical materials research.

[10]  T. Yamamuro,et al.  A new glass-ceramic for bone replacement: evaluation of its bonding to bone tissue. , 1985, Journal of biomedical materials research.

[11]  Sumio Sakka,et al.  Mechanical properties of a new type of apatite-containing glass-ceramic for prosthetic application , 1985 .

[12]  R. Haddad,et al.  The effect of surface treatments on the interface mechanics of LTI pyrolytic carbon implants. , 1985, Journal of biomedical materials research.

[13]  M. Ogino,et al.  Difference of bond bonding behavior among surface active glasses and sintered apatite. , 1984, Journal of biomedical materials research.

[14]  J. Wergedal,et al.  Fluoride directly stimulates proliferation and alkaline phosphatase activity of bone-forming cells. , 1983, Science.

[15]  J. Hobkirk Tissue reactions to implanted vitreous carbon and high purity sintered alumina. , 1977, Journal of oral rehabilitation.

[16]  J. L. Niles,et al.  Biomechanical evaluation of bone-porous material interfaces. , 1973, Journal of biomedical materials research.

[17]  Alan Boyde,et al.  The tandem scanning reflected light microscope , 1968 .

[18]  C. Rich,et al.  Effect of Sodium Fluoride on Calcium Metabolism of Human Beings , 1961, Nature.

[19]  Hobkirk Ja,et al.  Bone response to a matched modulus endosseous implant material. , 1989 .

[20]  J. Burnell,et al.  The effect of prolonged fluoride therapy for osteoporosis: Bone composition and histology , 1989 .

[21]  D. Spengler,et al.  Fixation of porous titanium implants in cortical bone enhanced by electrical stimulation. , 1981, Journal of biomedical materials research.

[22]  L L Hench,et al.  Compositional dependence of the formation of calcium phosphate films on bioglass. , 1980, Journal of biomedical materials research.