Comprehensive exergy-based evaluation and parametric study of a coal-fired ultra-supercritical power plant

In this paper, both conventional and advanced exergy analyses were conducted to a large-scale ultra-supercritical coal-fired power plant. The objectives of the conventional one are to compare the exergetic performances of different components, to identify and quantify the sites with the largest exergy destruction and losses, and to find the fuel-savings potential by improving each component in isolation. The advanced exergetic analysis focuses on the thermodynamic interactions among components and the sources for energy-saving potential of each component. Moreover, comparisons with several subcritical units are conducted and a sensitivity analysis shows the dependencies of the overall exergetic efficiency on a number of key design parameters. The results display the spatial distribution of exergy destruction and losses in detail and three performance ranges for different types of heat exchangers involved in the system. The energy-saving potentials at both the system and the component levels by improving an individual component are not in accordance with the amount of its exergy destruction. Improvement strategies for different components differ significantly due to the varied contributions of endogenous/exogenous parts to their avoidable exergy destructions. With an increase in the steam conditions, the exergy destruction ratio of the boiler is significantly reduced, contributing mainly to the system improvement. The most effective and achievable measure for reducing the fuel consumption is still the reasonable utilization of available low-grade heat. This framework provides a basis for the quantifying proposals of exergy-driven strategies for improving the system.

[1]  George Tsatsaronis,et al.  Design Optimization Using Exergoeconomics , 1999 .

[2]  Ibrahim Dincer,et al.  Thermodynamic analysis of reheat cycle steam power plants , 2001 .

[3]  Cheng Xu,et al.  Novel partial-subsidence tower-type boiler design in an ultra-supercritical power plant , 2014 .

[4]  Isam H. Aljundi,et al.  Energy and exergy analysis of a steam power plant in Jordan , 2009 .

[5]  Tatiana Morosuk,et al.  Advanced Exergy Analysis for Chemically Reacting Systems – Application to a Simple Open Gas-Turbine System , 2009 .

[6]  Tatiana Morosuk,et al.  Advanced exergetic analysis : Approaches for splitting the exergy destruction into endogenous and exogenous parts , 2009 .

[7]  Ajit Kumar Kolar,et al.  ANN-GA based optimization of a high ash coal-fired supercritical power plant , 2011 .

[8]  M. J. Moran,et al.  Thermal design and optimization , 1995 .

[9]  J. B. Young,et al.  Exergy Analysis of Modern Fossil-Fuel Power Plants , 2000 .

[10]  A. Kumagai,et al.  Viscosity of saturated liquid fluorocarbon refrigerants from 273 to 353 K , 1991 .

[11]  Robert Taud,et al.  Status and perspectives of fossil power generation , 2004 .

[12]  Tatiana Morosuk,et al.  Multi-objective optimization of coal-fired power plants using differential evolution , 2014 .

[13]  Tatiana Morosuk,et al.  Advanced Thermodynamic Analysis and Evaluation of a Supercritical Power Plant , 2012 .

[14]  Tatiana Morosuk,et al.  Steam Methane Reforming System for Hydrogen Production: Advanced Exergetic Analysis , 2012 .

[15]  Bin Huang,et al.  Industrial test and techno-economic analysis of CO2 capture in Huaneng Beijing coal-fired power station , 2010 .

[16]  George Tsatsaronis,et al.  Recent developments in exergy analysis and exergoeconomics , 2008 .

[17]  T. J. Kotas,et al.  The Exergy Method of Thermal Plant Analysis , 2012 .

[18]  Dexin Wang,et al.  Coal power plant flue gas waste heat and water recovery , 2012 .

[19]  M. J. Moran,et al.  Fundamentals of Engineering Thermodynamics , 2014 .

[20]  Yongping Yang,et al.  Power generation from pulverized coal in China , 2010 .

[21]  Amitava Datta,et al.  Exergy analysis of a coal‐based 210 MW thermal power plant , 2007 .

[22]  George Tsatsaronis,et al.  ON AVOIDABLE AND UNAVOIDABLE EXERGY DESTRUCTIONS AND INVESTMENT COSTS IN THERMAL SYSTEMS , 2002 .

[23]  Alireza Bahadori,et al.  Estimation of potential savings from reducing unburned combustible losses in coal-fired systems , 2010 .

[24]  Michael J. Moran,et al.  Availability analysis: A guide to efficient energy use , 1982 .

[25]  János M. Beér,et al.  High efficiency electric power generation: The environmental role , 2007 .

[26]  Luis M. Romeo,et al.  Optimization of boiler cold-end and integration with the steam cycle in supercritical units , 2010 .

[27]  Judith Gurney BP Statistical Review of World Energy , 1985 .

[28]  Tatiana Morosuk,et al.  A General Exergy-Based Method for Combining a Cost Analysis With an Environmental Impact Analysis: Part I — Theoretical Development , 2008 .

[29]  Amitava Datta,et al.  Exergy-based performance analysis for proper O&M decisions in a steam power plant , 2010 .

[30]  Rudolph Blum,et al.  High-efficiency coal-fired power plants development and perspectives , 2006 .

[31]  Yemane Wolde-Rufael,et al.  Coal consumption and economic growth revisited , 2010 .

[32]  Tatiana Morosuk,et al.  Advanced exergetic evaluation of refrigeration machines using different working fluids , 2009 .

[33]  Jan Szargut,et al.  Exergy Analysis of Thermal, Chemical, and Metallurgical Processes , 1988 .

[34]  Tatiana Morosuk,et al.  Advanced exergetic analysis of a novel system for generating electricity and vaporizing liquefied natural gas , 2010 .

[35]  Yuji Fukuda Development of Advanced Ultra Supercritical Fossil Power Plants in Japan: Materials and High Temperature Corrosion Properties , 2011 .

[36]  Yiping Dai,et al.  Exergy analyses and parametric optimizations for different cogeneration power plants in cement industry , 2009 .

[37]  Henrik Lund,et al.  Feasibility of a 1400 MW coal-fired power-plant in Thailand , 2003 .

[38]  Tatiana Morosuk,et al.  A General Exergy-Based Method for Combining a Cost Analysis With an Environmental Impact Analysis: Part II — Application to a Cogeneration System , 2008 .

[39]  Andrea Lazzaretto,et al.  SPECO: A systematic and general methodology for calculating efficiencies and costs in thermal systems , 2006 .

[40]  Paul S. Weitzel,et al.  Steam Generator for Advanced Ultra Supercritical Power Plants 700C to 760C , 2011 .

[41]  Zengliang Gao,et al.  Avoidable thermodynamic inefficiencies and costs in an externally fired combined cycle power plant , 2006 .

[42]  Shien Hui,et al.  Study of optimal pulverized coal concentration in a four-wall tangentially fired furnace , 2011 .

[43]  Fan Ying,et al.  Does generation form influence environmental efficiency performance? An analysis of China’s power system , 2012 .