Quench Detection Diagnostics on 3.9 GHz XFEL Cavities

This paper presents results of quench localization on 3.9 GHz XFEL prototype cavities tested at LASA vertical test facility. Cavities have been equipped with OST second sound detectors and thermometry sensors. A first guess for quench position has been obtained from modal analysis. Second sound sensors confirmed the quench position resolving also the symmetry degeneracy given by the RF mode pattern analysis. In a subsequent vertical test, second sound and temperature sensors have been installed nearby the suspect quench position. From thermometry mapping, a sudden increase in cavity temperature within a small region is evident, therefore confirming that a local thermal breakdown due to defect heating occurs in the predicted quench point. The quench region deduced with the mentioned techniques is then compared with results of optical inspection.