Characterization of a 6 kW high-flux solar simulator with an array of xenon arc lamps capable of concentrations of nearly 5000 suns.

A systematic methodology for characterizing a novel and newly fabricated high-flux solar simulator is presented. The high-flux solar simulator consists of seven xenon short-arc lamps mounted in truncated ellipsoidal reflectors. Characterization of spatial radiative heat flux distribution was performed using calorimetric measurements of heat flow coupled with CCD camera imaging of a Lambertian target mounted in the focal plane. The calorimetric measurements and images of the Lambertian target were obtained in two separate runs under identical conditions. Detailed modeling in the high-flux solar simulator was accomplished using Monte Carlo ray tracing to capture radiative heat transport. A least-squares regression model was used on the Monte Carlo radiative heat transfer analysis with the experimental data to account for manufacturing defects. The Monte Carlo ray tracing was calibrated by regressing modeled radiative heat flux as a function of specular error and electric power to radiation conversion onto measured radiative heat flux from experimental results. Specular error and electric power to radiation conversion efficiency were 5.92 ± 0.05 mrad and 0.537 ± 0.004, respectively. An average radiative heat flux with 95% errors bounds of 4880 ± 223 kW ⋅ m(-2) was measured over a 40 mm diameter with a cavity-type calorimeter with an apparent absorptivity of 0.994. The Monte Carlo ray-tracing resulted in an average radiative heat flux of 893.3 kW ⋅ m(-2) for a single lamp, comparable to the measured radiative heat fluxes with 95% error bounds of 892.5 ± 105.3 kW ⋅ m(-2) from calorimetry.

[1]  C. Ho,et al.  A Photographic Flux Mapping Method for Concentrating Solar Collectors and Receivers , 2012 .

[2]  Ulrich Vogt,et al.  Solar Thermochemical CO2 Splitting Utilizing a Reticulated Porous Ceria Redox System , 2012 .

[3]  Peter G. Loutzenhiser,et al.  Review of the Two-Step H2O/CO2-Splitting Solar Thermochemical Cycle Based on Zn/ZnO Redox Reactions , 2010, Materials.

[4]  B. Erickson,et al.  Inverse identification of intensity distributions from multiple flux maps in concentrating solar applications , 2012 .

[5]  Eckhard Lüpfert,et al.  Beam Characterization and Improvement with a Flux Mapping System for Dish Concentrators , 2002 .

[6]  Aldo Steinfeld,et al.  A Novel 50kW 11,000 suns High-Flux Solar Simulator Based on an Array of Xenon Arc Lamps , 2007 .

[7]  C. Estrada,et al.  A flat-plate calorimeter for concentrated solar flux evaluation , 2008 .

[8]  C. Estrada,et al.  Heat transfer analysis in a calorimeter for concentrated solar radiation measurements , 2007 .

[9]  Marc Röger,et al.  Infrared-Reflective Coating on Fused Silica for a Solar High-Temperature Receiver , 2007 .

[10]  Michael F. Modest,et al.  CHAPTER 22 – INVERSE RADIATIVE HEAT TRANSFER , 2003 .

[11]  Nesrin Ozalp,et al.  Description and characterization of an adjustable flux solar simulator for solar thermal, thermochemical and photovoltaic applications , 2014 .

[12]  S. F. Rice,et al.  Methane Partial Oxidation Catalyzed by Platinum and Rhodium in a High-Temperature Stagnation Flow Reactor , 2007 .

[13]  Wojciech Lipiński,et al.  Optical Design of Multisource High-Flux Solar Simulators , 2015 .

[14]  W. Chueh,et al.  High-Flux Solar-Driven Thermochemical Dissociation of CO2 and H2O Using Nonstoichiometric Ceria , 2010, Science.

[15]  Claudio A. Estrada,et al.  High-heat-flux sensor calibration using calorimetry , 2004 .

[16]  A. Neumann,et al.  Development and Test of a High Flux Calorimeter at DLR Cologne , 1999 .

[17]  Robert Gardon,et al.  An Instrument for the Direct Measurement of Intense Thermal Radiation , 1953 .

[18]  H. Manz,et al.  Empirical validation of models to compute solar irradiance on inclined surfaces for building energy simulation , 2007 .

[19]  Aldo Steinfeld,et al.  A New 75 kW High-Flux Solar Simulator for High-Temperature Thermal and Thermochemical Research , 2003 .

[20]  Feasibility study on non-windowed solar reactor: ZnO carboreduction as an example , 2006 .

[21]  G. Johnston Focal region measurements of the 20 m2 tiled dish at the Australian National University , 1998 .

[22]  Wojciech Lipiński,et al.  Operational Performance of the University of Minnesota 45 kWe High-Flux Solar Simulator , 2013 .

[23]  Wojciech Lipiński,et al.  Review of Heat Transfer Research for Solar Thermochemical Applications , 2013 .

[24]  Ivo Alxneit,et al.  Spectral Characterization of PSI’s High-Flux Solar Simulator , 2012 .

[25]  L. W. Langley,et al.  Systematic error in the measurement of very high solar irradiance , 2003 .

[26]  J. B. Blackmon Development and Performance of a Digital Image Radiometer for Heliostat Evaluation at Solar One , 1985 .

[27]  Claudio A. Estrada,et al.  Heat flux sensors: Calorimeters or radiometers? , 2006 .

[28]  A. Steinfeld,et al.  A Modular Ceramic Cavity-Receiver for High-Temperature High-Concentration Solar Applications , 2012 .

[29]  R. Monterreal,et al.  Hybrid heat flux measurement system for solar central receiver evaluation , 2004 .