ANALYSIS OF OPTIMAL LOCATION OF SUPERCONDUCTING FAULT CURRENT LIMITER FOR THE SMART GRID
暂无分享,去创建一个
[1] Dong Keun Park,et al. Study on a Series Resistive SFCL to Improve Power System Transient Stability: Modeling, Simulation, and Experimental Verification , 2009, IEEE Transactions on Industrial Electronics.
[2] Hoang Le-Huy,et al. A power system simulation tool based on Simulink , 1999, IEEE Trans. Ind. Electron..
[3] J. Sheng,et al. The Structure, Performance and Recovery Time of a 10 kV Resistive Type Superconducting Fault Current Limiter , 2013, IEEE Transactions on Applied Superconductivity.
[4] Kari Mäki,et al. Effect of wind power based distributed generation on protection of distribution network , 2004 .
[5] Werner Friedl,et al. Safety and reliability for Smart-, Micro- and islanded grids , 2009 .
[6] Shigeyuki Sugimoto,et al. Principle and characteristics of a fault current limiter with series compensation , 1996 .
[7] G Tang,et al. APPLICATION OF A FAULT CURRENT LIMITER TO MINIMIZE DISTRIBUTED GENERATION IMPACT ON COORDINATED RELAY PROTECTION , 2005 .
[8] Lin Ye,et al. Study of Superconducting Fault Current Limiters for System Integration of Wind Farms , 2010, IEEE Transactions on Applied Superconductivity.
[9] I. Vajda,et al. Superconducting FCL: design and application , 2004, IEEE Transactions on Applied Superconductivity.
[10] Y. Chen,et al. Design and Application of a Superconducting Fault Current Limiter in DC Systems , 2014, IEEE Transactions on Applied Superconductivity.
[11] G. M. Burt,et al. Current–Time Characteristics of Resistive Superconducting Fault Current Limiters , 2012, IEEE Transactions on Applied Superconductivity.
[12] Dong Keun Park,et al. Study on Optimal Location of a Resistive SFCL Applied to an Electric Power Grid , 2009, IEEE Transactions on Applied Superconductivity.
[13] Y. Shirai,et al. Improvement of Power System Stability by Use of Superconducting Fault Current Limiter With ZnO Device and Resistor in Parallel , 2008, IEEE Transactions on Applied Superconductivity.
[14] Wolfgang Schmidt,et al. Superconducting Fault Current Limiter for Transmission Voltage , 2012 .
[15] Liangzhen Lin,et al. Application studies of superconducting fault current limiters in electric power systems , 2002 .
[16] Ok-Bae Hyun,et al. Stability analysis of a power system with superconducting fault current limiter installed , 2001 .
[17] Werner Friedl,et al. Safety and reliability for Smart-, Micro- and islanded grids , 2008 .
[18] S H Lee,et al. Feasibility Analysis of the Positioning of Superconducting Fault Current Limiters for the Smart Grid Application Using Simulink and SimPowerSystem , 2011, IEEE Transactions on Applied Superconductivity.
[19] Joachim Bock,et al. Superconducting Fault Current Limiters - a new device for future smart grids , 2012, 2012 China International Conference on Electricity Distribution.
[20] J. Driesen,et al. Protection Issues in Microgrids with Multiple Distributed Generation Units , 2007, 2007 Power Conversion Conference - Nagoya.
[21] Mathias Noe,et al. The ECOFLOW project: design and simulations results of a superconducting fault current limiter for operation in electricity networks , 2011 .
[22] P. V. Balasubramanyam,et al. Development of 440-V 800-A Resistive-Type Modular Superconducting Fault Current Limiter With YBCO Tapes , 2012, IEEE Transactions on Applied Superconductivity.
[23] R. Cherkaoui,et al. Enhancement of power system transient stability using superconducting fault current limiters , 1999, IEEE Transactions on Applied Superconductivity.
[24] Yasunori Mitani,et al. Optimal location assignment and design of superconducting fault current limiters applied to loop power systems , 2003 .
[25] A. Rama Devi,et al. Simulation of Resistive Super Conducting Fault Current Limiter and Its Performance Analysis In Three Phase Systems , 2013 .