Fault Ride-Through Capability Enhancement Strategy for VSC-HVDC Systems Supplying for Passive Industrial Installations

This paper proposes a modified current-limit strategy (MCLS) and a frequency hysteresis control (FHC) for improving the disturbance ride-through capability of a VSC-HVDC link supplying passive industrial installations. Since industrial loads are more sensitive to voltage drops than frequency deviations, it is essential to guarantee the stability of voltage during severe faults. The development of the control methods includes three steps. First, the main factor that affects the ac voltage in the passive industrial system is analyzed in order to enhance the voltage stability more effectively. Second, according to the analytical results, the MCLS is proposed to increase the ac voltage in transient conditions. Third, in order to make the MCLS have a better control result, the FHC is added to the VSC controller with the MCLS, which can also further enhance the ac voltage of the passive system. The simulation tests under metallic single-phase and three-phase faults are performed in PSCAD/EMTDC, and the results verify the validity of the control methods.

[1]  Hairong Chen Research on the control strategy of VSC based HVDC system supplying passive network , 2009, 2009 IEEE Power & Energy Society General Meeting.

[2]  Gyu-Hong Kang,et al.  Analysis of power system harmonics for an offshore design with VTB dynamic model , 2012, 2012 IEEE Vehicle Power and Propulsion Conference.

[3]  P. Kundur,et al.  Power system stability and control , 1994 .

[4]  Chunyi Guo,et al.  Supply of an Entirely Passive AC Network Through a Double-Infeed HVDC System , 2010, IEEE Transactions on Power Electronics.

[5]  C. Grigg,et al.  Proposed chapter 9 for predicting voltage sags (dips) in revision to IEEE Std 493, the gold book , 1994, Proceedings of IEEE/PES Transmission and Distribution Conference.

[6]  A. Sannino,et al.  A New Control Strategy of a VSC–HVDC System for High-Quality Supply of Industrial Plants , 2007, IEEE Transactions on Power Delivery.

[7]  Lidong Zhang Modeling and Control of VSC-HVDC Links Connected to Weak AC Systems , 2010 .

[8]  Jia Xu,et al.  Faults mitigation control design for grid integration of offshore wind farms and oil & gas installations using VSC HVDC , 2010, SPEEDAM 2010.

[9]  I. Erlich,et al.  Enhanced Fault Ride-Through Method for Wind Farms Connected to the Grid Through VSC-Based HVDC Transmission , 2009, IEEE Transactions on Power Systems.

[10]  Dylan Dah-Chuan Lu,et al.  Enhancement of voltage quality in a passive network supplied by a VSC-HVDC transmission under disturbances , 2014 .

[11]  Chen-Ching Liu,et al.  Parameter Identification With PMUs for Instability Detection in Power Systems With HVDC Integrated Offshore Wind Energy , 2014, IEEE Transactions on Power Systems.

[12]  G. Olsson,et al.  Comparison of Different Frequency Controllers for a VSC-HVDC Supplied System , 2008, IEEE Transactions on Power Delivery.

[13]  Zheng Xu,et al.  Modeling and Control of a Modular Multilevel Converter-Based HVDC System Under Unbalanced Grid Conditions , 2012, IEEE Transactions on Power Electronics.

[14]  H. Lesani,et al.  An optimal control strategy to alleviate sub-synchronous resonance in VSC-HVDC systems , 2009, 2009 2nd International Conference on Power Electronics and Intelligent Transportation System (PEITS).

[15]  Jing Zhang,et al.  Synchronous Generator Emulation Control Strategy for Voltage Source Converter (VSC) Stations , 2015, IEEE Transactions on Power Systems.

[16]  Gengyin Li,et al.  Modeling of VSC-HVDC and control strategies for supplying both active and passive systems , 2006, 2006 IEEE Power Engineering Society General Meeting.

[17]  Tore Undeland,et al.  Multi-Terminal VSC-HVDC System for Integration of Offshore Wind Farms and Green Electrification of Platforms in the North Sea , 2008 .

[18]  Jianhua Zhang,et al.  A study on VSC-HVDC based black start compared with traditional black start , 2009, 2009 International Conference on Sustainable Power Generation and Supply.

[19]  Kjetil Uhlen,et al.  Case Study of Integrating an Offshore Wind Farm with Offshore Oil and Gas Platforms and with an Onshore Electrical Grid , 2013 .

[20]  Zhe Chen,et al.  A Flexible Power Control Method of VSC-HVDC Link for the Enhancement of Effective Short-Circuit Ratio in a Hybrid Multi-Infeed HVDC System , 2013, IEEE Transactions on Power Systems.

[21]  Sheng Liu,et al.  Electromechanical Transient Modeling of Modular Multilevel Converter Based Multi-Terminal HVDC Systems , 2014, IEEE Transactions on Power Systems.

[22]  Zheng Xu,et al.  Control and modulation strategies for modular multilevel converter based HVDC system , 2011, IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society.

[23]  C.J. Melhorn,et al.  Voltage sags: their impact on the utility and industrial customers , 1996, Proceedings of 1996 IAS Industrial and Commercial Power Systems Technical Conference.

[24]  Qian Xu,et al.  Sliding mode robust control based active-power modulation of multi-terminal HVDC transmissions , 2016, 2016 IEEE Power and Energy Society General Meeting (PESGM).

[25]  V.G. Agelidis,et al.  VSC-Based HVDC Power Transmission Systems: An Overview , 2009, IEEE Transactions on Power Electronics.

[26]  M. J. Samotyj,et al.  Voltage sags in industrial systems , 1991, Conference Record. Industrial and Commercial Power Systems Technical Conference 1991.

[27]  J.O. Lamell,et al.  Offshore platform powered with new electrical motor drive system , 2005, Record of Conference Papers Industry Applications Society 52nd Annual Petroleum and Chemical Industry Conference.