Wide area measurement based security assessment & monitoring of modern power system: A danish power system case study

Power System security has become a major concern across the global power system community. This paper presents wide area measurement system (WAMS) based security assessment and monitoring of modern power system. A new three dimensional security index (TDSI) has been proposed for online security monitoring of modern power system with large scale renewable energy penetration. Phasor measurement unit (PMU) based WAMS has been implemented in western Danish Power System to realize online security monitoring and assessment in power system control center. The proposed security monitoring system has been demonstrated in DigSILENT PowerFactory environment.

[1]  R.T. Guttromson,et al.  Large-scale hybrid dynamic simulation employing field measurements , 2004, IEEE Power Engineering Society General Meeting, 2004..

[2]  V. Vittal,et al.  Annual Risk Assessment for Overload Security , 2001, IEEE Power Engineering Review.

[3]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[4]  A.G. Phadke,et al.  Synchronized phasor measurements in power systems , 1993, IEEE Computer Applications in Power.

[5]  Z. Bo,et al.  Dynamic phasor and frequency estimator for phasor measurement units , 2010 .

[6]  Alberto Berizzi,et al.  A second order method for contingency severity assessment with respect to voltage collapse , 2000 .

[7]  A. Bose,et al.  A fast voltage security assessment method using adaptive bounding , 1999, Proceedings of the 21st International Conference on Power Industry Computer Applications. Connecting Utilities. PICA 99. To the Millennium and Beyond (Cat. No.99CH36351).

[8]  S. Halilcevic,et al.  An on-line determination of the ready reserve power , 1999 .

[9]  Z. Chen,et al.  Challenges of Danish power system and their possible solutions , 2012, 2012 IEEE International Conference on Power System Technology (POWERCON).

[10]  Bharat Bhargava,et al.  Monitoring power system dynamics using phasor measurement technology for power system dynamic security assessment , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[11]  Anjan Bose,et al.  Contingency ranking based on severity indices in dynamic security analysis , 1999 .

[12]  Chen-Ching Liu,et al.  PMU-Based Monitoring of Rotor Angle Dynamics , 2011, IEEE Transactions on Power Systems.

[13]  Robert A. Schlueter,et al.  Justification of the voltage stability security assessment and diagnostic procedure using a bifurcation subsystem method , 2000 .

[14]  Tarlochan S. Sidhu,et al.  Contingency screening for steady-state security analysis by using FFT and artificial neural networks , 2000 .

[15]  Alexander Apostolov,et al.  IEEE PSRC Report on Global Industry Experiences With System Integrity Protection Schemes (SIPS) , 2010, IEEE Transactions on Power Delivery.