The use of spatially resolved fluorescence and reflectance to determine interface depth in layered fluorophore distributions.

The possibility of using spatially resolved fluorescence and reflectance measurements to recover tissue optical properties, fluorophore concentration and the thickness of a superficial layer in a two-layer geometry was investigated. A diffusion theory model was used to fit reflectance and fluorescence data generated using Monte Carlo simulations or experimentally obtained using tissue-simulating phantoms. Initial analysis fitting diffusion theory generated data suggested that it should be possible to recover all parameters from a single set of spatially resolved fluorescence and reflectance measurements. However, when Monte Carlo or experimental data were fitted the results were less impressive. Overall, it was shown that there is a strong coupling between interface depth, fluorophore concentration and tissue absorption, especially at larger depths. The recovery of all input parameters from a single set of spatially resolved measurements was limited to interface depths less than 3 mm, which is a reasonable range for measuring fluorophore in skin. When the tissue optical properties and fluorophore concentrations were known, then the interface depth could be monitored with good accuracy in simulated serial measurements. These results may also point to deficiencies in the diffusion theory model that introduce significant errors in the fitted results.

[1]  M S Patterson,et al.  A diffusion theory model of spatially resolved fluorescence from depth-dependent fluorophore concentrations. , 2001, Physics in medicine and biology.

[2]  P. Monnier,et al.  Optimizing light dosimetry in photodynamic therapy of early stage carcinomas of the esophagus using fluorescence spectroscopy , 1996, Lasers in surgery and medicine.

[3]  E. Sevick-Muraca,et al.  Quantitative optical spectroscopy for tissue diagnosis. , 1996, Annual review of physical chemistry.

[4]  Antonio Pifferi,et al.  Accelerated Monte Carlo models to simulate fluorescence spectra from layered tissues. , 2003, Journal of the Optical Society of America. A, Optics, image science, and vision.

[5]  P. R. Bevington,et al.  Data Reduction and Error Analysis for the Physical Sciences , 1969 .

[6]  L. O. Svaasand,et al.  Boundary conditions for the diffusion equation in radiative transfer. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[7]  M S Patterson,et al.  Modeling of photosensitizer fluorescence emission and photobleaching for photodynamic therapy dosimetry. , 1998, Applied optics.

[8]  J. Mourant,et al.  Ultraviolet and visible spectroscopies for tissue diagnostics: fluorescence spectroscopy and elastic-scattering spectroscopy. , 1997, Physics in medicine and biology.

[9]  M S Patterson,et al.  Monte carlo diffusion hybrid model for photon migration in a two-layer turbid medium in the frequency domain. , 2000, Applied optics.

[10]  M W Berns,et al.  Reflectance measurements of layered media with diffuse photon-density waves: a potential tool for evaluating deep burns and subcutaneous lesions. , 1999, Physics in medicine and biology.

[11]  Anthony J. Durkin,et al.  Comparison of methods to determine chromophore concentrations from fluorescence spectra of turbid samples , 1995, Lasers in surgery and medicine.

[12]  M. Patterson,et al.  Noninvasive determination of the optical properties of two-layered turbid media , 1998 .

[13]  M. Patterson,et al.  Accuracy of the diffusion approximation in determining the optical properties of a two-layer turbid medium. , 1998, Applied optics.

[14]  B. Wilson,et al.  In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications , 1998, Photochemistry and photobiology.

[15]  M S Patterson,et al.  Influence of layered tissue architecture on estimates of tissue optical properties obtained from spatially resolved diffuse reflectometry. , 1998, Applied optics.

[16]  J. Duncan,et al.  Noninvasive fluorescence detection of hepatic and renal function. , 1998, Journal of biomedical optics.

[17]  M. Patterson,et al.  Improved solutions of the steady-state and the time-resolved diffusion equations for reflectance from a semi-infinite turbid medium. , 1997, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  Brian W. Pogue,et al.  Mathematical model for time-resolved and frequency-domain fluorescence spectroscopy in biological tissues. , 1994, Applied optics.

[19]  B. Wilson,et al.  A diffusion theory model of spatially resolved, steady-state diffuse reflectance for the noninvasive determination of tissue optical properties in vivo. , 1992, Medical physics.