Ultrasound tissue displacement imaging with application to breast cancer.

A method for quantitative imaging of internal tissue motion based on speckle tracking is described. Tissue displacement images from eight patients with sonographically apparent breast masses are used to illustrate the technique. The local displacement response of tissues surrounding malignant and benign breast masses is compared, testing the hypothesis that altered mechanical properties may result in motion signatures for many soft tissue tumors relative to their host tissue. In addition, the potential or anticipated influence of various biological and physical factors on tissue motion response is discussed.

[1]  W. Leucht,et al.  Diagnostic value of different interpretative criteria in real-time sonography of the breast. , 1988, Ultrasound in medicine & biology.

[2]  J. Meunier,et al.  Ultrasonic biomechanical strain gauge based on speckle tracking , 1989, Proceedings., IEEE Ultrasonics Symposium,.

[3]  John W. Berg Clinical implications of risk factors for breast cancer , 1984, Cancer.

[4]  E. Robert Heitzman,et al.  The lung, radiologic-pathologic correlations , 1973 .

[5]  D. Carmody,et al.  Limitations in distinguishing malignant from benign lesions of the breast by systematic review of mammograms. , 1991, Surgery, gynecology & obstetrics.

[6]  L J van Bogaert,et al.  Importance of spicules on clinical staging of carcinoma of the breast. , 1977, Surgery, gynecology & obstetrics.

[7]  R. Leborgne Diagnosis of tumors of the breast by simple roentgenography; calcifications in carcinomas. , 1951, The American journal of roentgenology and radium therapy.

[8]  E A Sickles,et al.  Mammographic features of "early" breast cancer. , 1984, AJR. American journal of roentgenology.

[9]  J. Wolfe,et al.  Xeroradiography of the breast. , 1983, Geriatrics.

[10]  W.K. Jenkins,et al.  The impact of various imaging parameters on ultrasonic displacement and velocity estimates , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[11]  M. Moskowitz,et al.  Breast cancer missed by mammography. , 1979, AJR. American journal of roentgenology.

[12]  J. Ophir,et al.  Elastography: A Quantitative Method for Imaging the Elasticity of Biological Tissues , 1991, Ultrasonic imaging.

[13]  S. Ciatto,et al.  Radial scars of the breast: review of 38 consecutive mammographic diagnoses. , 1993, Radiology.

[14]  H. Gallager,et al.  Early phases in the development of breast cancer , 1969, Cancer.

[15]  A.R. Skovoroda,et al.  Tissue elasticity reconstruction based on ultrasonic displacement and strain images , 1995, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Characteristic echographic features of circumscribed cancer. , 1982, Ultrasound in medicine & biology.

[17]  J C Bamber,et al.  Quantitative evaluation of real-time ultrasound features of the breast. , 1988, Ultrasound in medicine & biology.

[18]  K. Krecke,et al.  Invasive lobular carcinoma of the breast: mammographic findings and extent of disease at diagnosis in 184 patients. , 1993, AJR. American journal of roentgenology.

[19]  Stanislav Emelianov,et al.  Biophysical Bases of Elasticity Imaging , 1995 .

[20]  G E Trahey,et al.  Potential and limitations of angle-independent flow detection algorithms using radio-frequency and detected echo signals. , 1991, Ultrasonic imaging.

[21]  J. Ophir,et al.  Elastography: Elasticity Imaging Using Ultrasound with Application to Muscle and Breast in Vivo , 1993, Ultrasonic imaging.

[22]  Lawrence W. Bassett,et al.  Mammography, thermography, and ultrasound in breast cancer detection , 1982 .

[23]  R. McLelland,et al.  Stellate lesions of the breast. , 1990, Recent results in cancer research. Fortschritte der Krebsforschung. Progres dans les recherches sur le cancer.

[24]  K Itoh,et al.  Dynamic tests in real-time breast echography. , 1988, Ultrasound in medicine & biology.

[25]  M Moskowitz,et al.  Screening is not diagnosis. , 1979, Radiology.

[26]  P. Bland,et al.  Quantitative tissue motion analysis of digitized M-mode images: gestational differences of fetal lung. , 1990, Ultrasound in medicine & biology.

[27]  M. O’Donnell,et al.  Internal displacement and strain imaging using ultrasonic speckle tracking , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[29]  B. Kruse,et al.  Tubular carcinoma of the breast: mammographic appearance. , 1993, AJR. American journal of roentgenology.

[30]  M. O’Donnell,et al.  Theoretical analysis and verification of ultrasound displacement and strain imaging , 1994, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[31]  L. Tabár,et al.  Teaching atlas of mammography. , 1983, Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin. Erganzungsband.

[32]  V. Vlaisavljevic Differentiation of solid breast tumors on the basis of their primary echographic characteristics as revealed by real-time scanning of the uncompressed breast. , 1988, Ultrasound in medicine & biology.

[33]  W.D. O'Brien,et al.  Current time-domain methods for assessing tissue motion by analysis from reflected ultrasound echoes-a review , 1993, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.