Investigation of indoor environmental quality in Shanghai metro stations, China

A field study was carried out in Shanghai metro stations to gather and evaluate information about the real environment. The thermal environment and particulate matter levels were monitored in this study. The mean thermal sensation vote in metro stations was 0.91, and the mean thermal neutral temperature was 20.6°C. Although 92.1% of subjects voted that the thermal environment was acceptable, the condition of air quality in Shanghai metro stations was not good. The mean levels of PM1.0, PM2.5, and PM10 were 0.231 ± 0.152, 0.287 ± 0.177, and 0.366 ± 0.193 mg/m3, respectively. The contribution of PM1.0 to PM2.5 and PM2.5 to PM10 was up to 79% and 76%, respectively. This means that fine particles or ultrafine particles constituted the preponderant part of metro station particulate matter.

[1]  Timo Mäkelä,et al.  The concentrations and composition of and exposure to fine particles (PM2.5) in the Helsinki subway system , 2005 .

[2]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[3]  P. O. Fanger,et al.  Thermal comfort: analysis and applications in environmental engineering, , 1972 .

[4]  K. Cena,et al.  Field study of occupant comfort and office thermal environments in a hot, arid climate , 1999 .

[5]  Refrigerating ASHRAE handbook of fundamentals , 1967 .

[6]  Z. Lian,et al.  Field study of a thermal environment and adaptive model in Shanghai. , 2006, Indoor air.

[7]  Yang Man,et al.  Views on Standard of Indoor Air Quality (GB/T 18883-2002) , 2003 .

[8]  L Morawska,et al.  Relation between indoor and outdoor exposure to fine particles near a busy arterial road. , 1999, Indoor air.

[9]  Microanalysis of indoor aerosols and the impact of a compact high-efficiency particulate air (HEPA) filter system. , 1999, Indoor air.

[10]  Péter Ordódy THERMAL COMFORT IN THE PASSENGER AREAS OF THE BUDAPEST METRO , 2000 .

[11]  Olli Seppänen,et al.  The Effects Of Air Temperature And Relative Humidity On Thermal Comfort In The Office Environment , 1993 .

[12]  H Rüden,et al.  Elemental carbon and respirable particulate matter in the indoor air of apartments and nursery schools and ambient air in Berlin (Germany). , 2005, Indoor air.

[13]  Martin Braniš,et al.  The contribution of ambient sources to particulate pollution in spaces and trains of the Prague underground transport system , 2006 .

[14]  K. Mui,et al.  Neutral temperature in subtropical climates—A field survey in air-conditioned offices , 2007 .

[15]  Dong Li,et al.  Thermal Comfort and Air Quality in Passenger Rail Cars , 2004 .