Approach for Self-Calibrating CO2 Measurements with Linear Membrane-Based Gas Sensors

Linear membrane-based gas sensors that can be advantageously applied for the measurement of a single gas component in large heterogeneous systems, e.g., for representative determination of CO2 in the subsurface, can be designed depending on the properties of the observation object. A resulting disadvantage is that the permeation-based sensor response depends on operating conditions, the individual site-adapted sensor geometry, the membrane material, and the target gas component. Therefore, calibration is needed, especially of the slope, which could change over several orders of magnitude. A calibration-free approach based on an internal gas standard is developed to overcome the multi-criterial slope dependency. This results in a normalization of sensor response and enables the sensor to assess the significance of measurement. The approach was proofed on the example of CO2 analysis in dry air with tubular PDMS membranes for various CO2 concentrations of an internal standard. Negligible temperature dependency was found within an 18 K range. The transformation behavior of the measurement signal and the influence of concentration variations of the internal standard on the measurement signal were shown. Offsets that were adjusted based on the stated theory for the given measurement conditions and material data from the literature were in agreement with the experimentally determined offsets. A measurement comparison with an NDIR reference sensor shows an unexpectedly low bias (<1%) of the non-calibrated sensor response, and comparable statistical uncertainty.

[1]  T. Tille,et al.  A High-Precision NDIR $\hbox{CO}_{2}$ Gas Sensor for Automotive Applications , 2006, IEEE Sensors Journal.

[2]  W. L. Robb,et al.  THIN SILICONE MEMBRANES‐THEIR PERMEATION PROPERTIES AND SOME APPLICATIONS , 1968, Annals of the New York Academy of Sciences.

[3]  E. Llobet,et al.  Multicomponent gas mixture analysis using a single tin oxide sensor and dynamic pattern recognition , 2001, IEEE Sensors Journal.

[4]  T. Sauer,et al.  Porous tubing for use in monitoring soil CO2 concentrations , 2006 .

[5]  J. Namieśnik,et al.  Selected concentration techniques for gas chromatographic analysis of environmental samples , 2002 .

[6]  H. Geistlinger,et al.  A new method for membrane-based gas measurements , 2005 .

[7]  M. Lumbreras,et al.  Elaboration and characterization of tin oxide–lanthanum oxide mixed layers prepared by the electrostatic spray pyrolysis technique , 2001 .

[8]  Sebastian Ebert,et al.  Improved Membrane-Based Sensor Network for Reliable Gas Monitoring in the Subsurface , 2012, Sensors.

[9]  Xiaowen Xu,et al.  Zeolite-based Materials for Gas Sensors , 2006 .

[10]  E. Rideal,et al.  Permeation, diffusion and solution of gases in organic polymers , 1939 .

[11]  Sebastian Ebert,et al.  Membrane Based Measurement Technology for in situ Monitoring of Gases in Soil , 2009, Sensors.

[12]  A. Michaels,et al.  Diffusion and solution of gases in composite rubber membranes , 1963 .

[13]  王跃思,et al.  Quick Measurement of CH4, CO2 and N2O Emissions from a Short-Plant Ecosystem , 2003 .

[14]  A. Bahr,et al.  A review of continuous soil gas monitoring related to CCS - Technical advances and lessons learned , 2013 .

[15]  Khalil Arshak,et al.  A review of gas sensors employed in electronic nose applications , 2004 .

[16]  S. Akbar,et al.  Solid‐State Gas Sensors: A Review , 1992 .

[17]  R. Capuano,et al.  Solid-state gas sensors for breath analysis: a review. , 2014, Analytica chimica acta.

[18]  Tadeusz Górecki,et al.  Applications of polydimethylsiloxane in analytical chemistry: a review. , 2012, Analytica chimica acta.

[19]  Jürgen Augustin,et al.  Automated Gas Chromatographic System for Rapid Analysis of the Atmospheric Trace Gases Methane, Carbon Dioxide, and Nitrous Oxide , 1997 .

[20]  H. Meijer,et al.  A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and CO , 2009 .

[21]  Yu-Lung Lo,et al.  Fiber-optic carbon dioxide sensor based on fluorinated xerogels doped with HPTS , 2008, International Conference on Optical Fibre Sensors.

[22]  Yang Sun,et al.  An improved gas chromatography for rapid measurement of CO2, CH4 and N2O. , 2006, Journal of environmental sciences.

[23]  R. Neubert,et al.  A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and CO , 2009 .

[24]  Thick film CO2 sensors based on Nasicon solid electrolyte , 2003 .

[25]  Wolfgang Göpel,et al.  Multicomponent gas analysis of a mixture of chloroform, octane and toluene using a piezoelectric quartz crystal sensor array , 1999 .

[26]  S. Jacobson,et al.  New developments in ultrasonic gas analysis and flowmetering , 2008, 2008 IEEE Ultrasonics Symposium.

[27]  Daqiang Zhang,et al.  A Survey on Gas Sensing Technology , 2012, Sensors.

[28]  R. Wolffenbuttel,et al.  Sensor platform for gas composition measurement , 2011 .

[29]  Mohamad Sawan,et al.  Review of recent trends in gas sensing technologies and their miniaturization potential , 2014 .

[30]  Wang Yue-si,et al.  Quick measurement of CH4, CO2 and N2O emissions from a short-plant ecosystem , 2003 .

[31]  Yu-Lung Lo,et al.  Review on recent developments of fluorescent oxygen and carbon dioxide optical fiber sensors , 2011 .

[32]  Jongwon Kwon,et al.  A study on NDIR-based CO2 sensor to apply remote air quality monitoring system , 2009, 2009 ICCAS-SICE.

[33]  T. Merkel,et al.  Gas sorption, diffusion, and permeation in poly(dimethylsiloxane) , 2000 .

[34]  P. Neumann,et al.  Characteristic length measurement of a subsurface gas anomaly—A monitoring approach for heterogeneous flow path distributions , 2016 .

[35]  Peter Werle,et al.  A review of recent advances in semiconductor laser based gas monitors , 1998 .

[36]  D. Lazik,et al.  First field test of linear gas sensor net for planar detection of CO2 leakages in the unsaturated zone , 2013 .