AbstractThis paper presents the results of experimental testing a novel dual-tube self-centering buckling-restrained brace (SC-BRB) with pretensioned basalt fiber-reinforced polymer (BFRP) composite tendons. Cyclic tensile experiments are first conducted on two sets of BFRP tendons with different diameters. The results confirm that the BFRP tendons have a stable cyclic elastic modulus and sufficient elongation capacity, making them suitable for use as the self-centering tendons in SC-BRBs. Quasi-static experiments are performed using two dual-tube SC-BRB specimens with different core plate areas. Before the failure of the self-centering system, both specimens stably exhibit the expected flag-shaped hysteresis response, with a relatively small residual deformation. The internal forces in the BFRP tendons and the gaps between the tubes and the end plates are measured to validate the performance of the self-centering system. Both specimens meet the requirements for ultimate ductility and cumulative ductility...

[1]  Hoseok Chi,et al.  Seismic behavior of post-tensioned column base for steel self-centering moment resisting frame , 2012 .

[2]  Robert Tremblay,et al.  Seismic testing and performance of buckling- restrained bracing systems , 2006 .

[3]  Chung-Che Chou,et al.  Analytical model validation and influence of column bases for seismic responses of steel post-tensioned self-centering MRF systems , 2011 .

[4]  Roberto T. Leon,et al.  Design and analysis of braced frames with shape memory alloy and energy-absorbing hybrid devices , 2010 .

[5]  Per Goltermann,et al.  Mechanical anchorage of FRP tendons – A literature review , 2012 .

[6]  C. L. Wang,et al.  Development of a novel self-centering buckling-restrained brace with BFRP composite tendons , 2014 .

[7]  Andre Filiatrault,et al.  Posttensioned Energy Dissipating Connections for Moment-Resisting Steel Frames , 2002 .

[8]  Chia-Ming Uang,et al.  Reducing residual drift of buckling-restrained braced frames as a dual system , 2006 .

[9]  Chung-Che Chou,et al.  Subassemblage tests and finite element analyses of sandwiched buckling-restrained braces , 2010 .

[10]  Matthew R. Eatherton,et al.  Development and experimental validation of a nickel–titanium shape memory alloy self-centering buckling-restrained brace , 2012 .

[11]  Richard Sause,et al.  Posttensioned Seismic-Resistant Connections for Steel Frames , 2001 .

[12]  S. Pessiki,et al.  Analytical and Experimental Lateral Load Behavior of Unbonded Posttensioned Precast Concrete Walls , 2007 .

[13]  Min Zhang,et al.  Seismic Behavior of Concrete Columns Reinforced by Steel-FRP Composite Bars , 2011 .

[14]  A. Refai Durability and Fatigue of Basalt Fiber-Reinforced Polymer Bars Gripped with Steel Wedge Anchors , 2013 .

[15]  Peter Dusicka,et al.  Global Restraint in Ultra-Lightweight Buckling-Restrained Braces , 2013 .

[16]  Hyunhoon Choi,et al.  Residual Drift Response of SMRFs and BRB Frames in Steel Buildings Designed according to ASCE 7-05 , 2011 .

[17]  James M. Ricles,et al.  Seismic Response and Performance of Buckling-Restrained Braced Frames , 2007 .

[18]  James M. Ricles,et al.  Experimental Evaluation of a Large-Scale Buckling-Restrained Braced Frame , 2007 .

[19]  Songye Zhu,et al.  Seismic Analysis of Concentrically Braced Frame Systems with Self-Centering Friction Damping Braces , 2008 .

[20]  Constantin Christopoulos,et al.  Seismic Response of Multistory Buildings with Self-Centering Energy Dissipative Steel Braces , 2008 .

[21]  Richard Sause,et al.  Seismic Performance of Post-tensioned Steel Moment Resisting Frames With Friction Devices , 2005 .

[22]  Donatello Cardone,et al.  Theoretical and Experimental Studies for the Application of Shape Memory Alloys in Civil Engineering , 2006 .

[23]  Richard Sause,et al.  Ductility demands on self-centering systems under earthquake loading , 2005 .

[24]  Robert Tremblay,et al.  Self-Centering Energy Dissipative Bracing System for the Seismic Resistance of Structures: Development and Validation , 2008 .

[25]  Stephen A. Mahin,et al.  Seismic demands on steel braced frame buildings with buckling-restrained braces , 2003 .

[26]  Richard Sause,et al.  Experimental studies of full-scale posttensioned steel connections , 2005 .

[27]  Sri Sritharan,et al.  Preliminary results and conclusions from the PRESSS five-story precast concrete test Building , 1999 .