Kilovoltage imaging doses in the radiotherapy of pediatric cancer patients.

PURPOSE To investigate doses induced by kilovoltage cone-beam computed tomography (kVCBCT) to pediatric cancer patients undergoing radiotherapy, as well as strategies for dose reduction. METHODS AND MATERIALS An EGS4 Monte Carlo code was used to calculate three-dimensional dose deposition due to kVCBCT on 4 pediatric cancer patients. Absorbed doses to various organs were analyzed for both half-fan and full-fan modes. Clinical conditions, such as distance from organ at risk (OAR) to CBCT field border, kV peak energy, and testicular shielding, were studied. RESULTS The mean doses induced by one CBCT scan operated at 125 kV in half-fan mode to testes, liver, kidneys, femoral heads, spinal cord, brain, eyes, lens, and optical nerves were 2.9, 4.7, 7.7, 10.5, 8.8, 7.6, 7.7, 7.8, and 7.2 cGy, respectively. Increasing the distances from OARs to CBCT field border greatly reduced the doses to OARs, ranging from 33% reduction for spinal cord to 2300% reduction for testes. As photon beam energy increased from 60 to 125 kV, the dose increase due to kVCBCT ranged from 170% for lens to 460% for brain and spinal cord. A testicular shielding made of 1-cm cerrobend could reduce CBCT doses down to 31%, 51%, 68%, and 82%, respectively, for 60, 80, 100, and 125 kV when the testes lay within the CBCT field. CONCLUSIONS Generally speaking, kVCBCT deposits much larger doses to critical structures in children than in adults, usually by a factor of 2 to 3. Increasing the distances from OARs to CBCT field border greatly reduces doses to OARs. Depending on OARs, kVCBCT-induced doses increase linearly or exponentially with photon beam energy. Testicular shielding works more efficiently at lower kV energies. On the basis of our study, it is essential to choose an appropriate scanning protocol when kVCBCT is applied to pediatric cancer patients routinely.

[1]  G. Ding,et al.  Accurate patient dosimetry of kilovoltage cone-beam CT in radiation therapy. , 2008, Medical physics.

[2]  G. Ding,et al.  Characteristics of kilovoltage x-ray beams used for cone-beam computed tomography in radiation therapy , 2007, Physics in medicine and biology.

[3]  C. Ma,et al.  BEAM: a Monte Carlo code to simulate radiotherapy treatment units. , 1995, Medical physics.

[4]  Z. Chen,et al.  Impact of Kilo-Voltage Cone Beam Computed Tomography on Image-Guided Radiotherapy of Prostate Cancer , 2009 .

[5]  Steve B. Jiang,et al.  A quality assurance phantom for IMRT dose verification , 2000, Proceedings of the 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (Cat. No.00CH37143).

[6]  R. Fisher,et al.  Testicular doses in definitive radiation therapy for localized prostate cancer. , 1995, International journal of radiation oncology, biology, physics.

[7]  L. Tanoue Computed Tomography — An Increasing Source of Radiation Exposure , 2009 .

[8]  Shuichi Ozawa,et al.  A dose comparison study between XVI and OBI CBCT systems. , 2008, Medical physics.

[9]  L. Dawson,et al.  Emerging Role of Radiotherapy in the Management of Liver Metastases , 2010, Cancer journal.

[10]  D. Jaffray,et al.  Evaluation of the effect of patient dose from cone beam computed tomography on prostate IMRT using Monte Carlo simulation. , 2007, Medical physics.

[11]  David A Jaffray,et al.  Patient dose from kilovoltage cone beam computed tomography imaging in radiation therapy. , 2006, Medical physics.

[12]  C. Ma,et al.  Accurate characterization of Monte Carlo calculated electron beams for radiotherapy. , 1996, Medical physics.

[13]  E. Nickoloff,et al.  Influence of phantom diameter, kVp and scan mode upon computed tomography dose index. , 2003, Medical physics.

[14]  A correction-based dose calculation algorithm for kilovoltage x rays. , 2008, Medical physics.

[15]  Michael B Sharpe,et al.  Image-guided radiotherapy: rationale, benefits, and limitations. , 2006, The Lancet. Oncology.

[16]  S M Seltzer,et al.  AAPM protocol for 40-300 kV x-ray beam dosimetry in radiotherapy and radiobiology. , 2001, Medical physics.

[17]  D. Rogers,et al.  EGS4 code system , 1985 .

[18]  T Pawlicki,et al.  Photon beam characterization and modelling for Monte Carlo treatment planning. , 2000, Physics in medicine and biology.

[19]  E. Halperin Pediatric radiation oncology. , 1986, Investigative radiology.

[20]  Lei Xing,et al.  American Society for Therapeutic Radiology and Oncology (ASTRO) and American College of Radiology (ACR) practice guidelines for image-guided radiation therapy (IGRT). , 2010, International journal of radiation oncology, biology, physics.

[21]  Joshua D. Lawson,et al.  A survey of image‐guided radiation therapy use in the United States , 2010, Cancer.

[22]  G. Ding,et al.  Inclusion of the dose from kilovoltage cone beam CT in the radiation therapy treatment plans. , 2009, Medical physics.

[23]  Cynthia Ménard,et al.  Imaging in Radiation Oncology: A Perspective , 2010, The oncologist.

[24]  C. Ma,et al.  A Monte Carlo dose calculation tool for radiotherapy treatment planning. , 2002, Physics in medicine and biology.

[25]  T. Schuster,et al.  Comparative analysis of an image-guided versus a non-image-guided setup approach in terms of delivered dose to the parotid glands in head-and-neck cancer IMRT. , 2010, International journal of radiation oncology, biology, physics.

[26]  Steve B. Jiang,et al.  Assessment of patient organ doses and effective doses using the VIP-Man adult male phantom for selected cone-beam CT imaging procedures during image guided radiation therapy. , 2008, Radiation protection dosimetry.

[27]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[28]  D. Brenner,et al.  Cancer risks from diagnostic radiology. , 2008, The British journal of radiology.

[29]  Charles W. Coffey,et al.  Radiation dose from kilovoltage cone beam computed tomography in an image-guided radiotherapy procedure. , 2009, International journal of radiation oncology, biology, physics.

[30]  S B Jiang,et al.  Validation of a Monte Carlo dose calculation tool for radiotherapy treatment planning , 2000, Physics in medicine and biology.

[31]  Frank Verhaegen,et al.  Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations. , 2006, Medical physics.

[32]  B. Movsas,et al.  Dose delivered from Varian's CBCT to patients receiving IMRT for prostate cancer , 2007, Physics in medicine and biology.

[33]  H. Christiansen,et al.  Testicular dose and hormonal changes after radiotherapy of rectal cancer. , 2005, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.