Behaviour of RC buildings with large lightly reinforced walls along the perimeter

Abstract Reinforced Concrete (RC) walls are defined as large lightly reinforced walls if they are not provided of high reinforcement percentage or if they are lack of reinforcement details usually required to improve the ductility of the structure. This type of walls gained relevance in 1950s–1970s constructions because of their good performances under seismic actions. Real earthquakes have, indeed, demonstrated that buildings constructed with large lightly reinforced walls, characterised by adequate area respect to the floor extension, could suffer lower damages in comparison with traditional RC framed buildings. Moreover, a widespread use of such a construction typology is outstanding thanks to the diffusion on the market of new types of integrated formworks, including insulating materials such as polystyrene, that are being used for casting concrete and are aimed to obtain a higher energetic efficiency and build structures made of continuous lightly reinforced walls. Nevertheless, there is a lack of both experimental information and specific design indications in technical codes on this type of construction. This paper firstly reviews the European code requirements for large lightly reinforced walls. Then, some experimental tests on RC walls in the existing literature are studied in detail also by means of a nonlinear Finite Element (FE) model. Finally, the performances of a whole RC building designed with both large lightly reinforced walls along the perimeter and internal frames have been also exploited by linear dynamic and static nonlinear analysis. The analysis are mainly aimed to highlight the influence of in-plane stiffness of the floor on the dynamic behaviour of the structure and to assess the contribution of both ductility and over-strength to the behaviour factor, i.e. to the seismic performance of such type of buildings, considering the lack of information in the technical literature about these features.

[1]  Sharon L. Wood,et al.  Collapse of eight-story RC building during 1985 Chile earthquake , 1991 .

[2]  Michael P. Collins,et al.  Predicting the Response of Reinforced Concrete Beams Subjected to Shear Using the Modified Compression Field Theory , 1988 .

[3]  Jack P. Moehle,et al.  Damage and Implications for Seismic Design of RC Structural Wall Buildings , 2012 .

[4]  E. Hernández-Montes,et al.  In-plane shear behaviour of thin low reinforced concrete panels for earthquake re-construction , 2013 .

[5]  Jack P. Moehle,et al.  "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI 318-11) AND COMMENTARY" , 2011 .

[6]  Mohammad Zaman Kabir,et al.  Dynamic behaviour of 3D-panel single-storey system using shaking table testing , 2008 .

[7]  M. Crisfield,et al.  Analysis of R/C panels using different concrete models , 1989 .

[8]  J. Mander,et al.  Theoretical stress strain model for confined concrete , 1988 .

[9]  Shen-Haw Ju,et al.  Comparison of Building Analyses Assuming Rigid or Flexible Floors , 2000 .

[10]  Andreas J. Kappos,et al.  Cyclic Load Behavior of Low-Slenderness Reinforced Concrete Walls: Design Basis and Test Results , 1999 .

[11]  Gaetano Manfredi,et al.  Behaviour of bond between concrete and steel in a large post-yelding field , 1996 .

[12]  Comite Euro-International du Beton,et al.  CEB-FIP Model Code 1990 , 1993 .

[13]  Evan C. Bentz,et al.  Explaining the Riddle of Tension Stiffening Models for Shear Panel Experiments , 2005 .

[14]  Jack P. Moehle,et al.  Seismic Design and Construction Practices for RC Structural Wall Buildings , 2012 .

[15]  C. Ledezma,et al.  Seismic Behavior of Squat Reinforced Concrete Shear Walls , 2002 .

[16]  Sharon L. Wood,et al.  Performance of Reinforced Concrete Buildings during the 1985 Chile Earthquake: Implications for the Design of Structural Walls , 1991 .

[17]  Hassan S. Saffarini,et al.  In-Plane Floor Deformations in RC Structures , 1992 .

[18]  A. Kappos,et al.  Cyclic Load Behavior of Low-Slenderness Reinforced Concrete Walls: Failure Modes, Strength and Deformation Analysis, and Design Implications , 2000 .

[19]  John W. Wallace,et al.  Investigation of the Axial Load Capacity for Lightly Reinforced Wall Piers , 2008 .

[20]  John W. Wallace,et al.  Shear Strength of Lightly Reinforced Wall Piers and Spandrels , 2009 .

[21]  John Butterworth,et al.  Behaviour of Inadequately Detailed Reinforced Concrete Walls , 2011 .