Symmetrical fault detection technique during power swing based on S-Transform

Disturbances in a power system such as line switching and sudden removal of faults may cause instability which lead to the power swing phenomenon. During a power swing, the mal-operation of distance relay is among the problem which needs to be solved. In the case of a power swing, a distance relay is designed to block detection to avoid wrong interpretation of relay current signals. However, this blocking scheme proves to be unreliable as it could block the trip signals when a genuine fault occurs in the system during a power swing. Hence, it is vital to develop a proper fault detection technique during a power swing to avoid such circumstances. This paper presents a detection technique to detect symmetrical faults during a power swing based on the time frequency transform known as S-Transform. To ascertain validity of the proposed scheme, it was verified with the IEEE 14-bus system and simulation results showed that the proposed technique was able to detect symmetrical faults occurring in the power system.

[1]  Claudio A. Canizares,et al.  Indices to detect hopf bifurcation in power systems , 2000 .

[2]  D. Tholomier,et al.  Fast detector of symmetrical fault during power swing for distance relay , 2005, IEEE Power Engineering Society General Meeting, 2005.

[3]  David Thomas,et al.  A new blocking principle with phase and earth fault detection during fast power swings for distance protection , 1995 .

[4]  Yu-Hsiang Wang,et al.  The Tutorial : S Transform , 2010 .

[5]  Mladen Kezunovic,et al.  Fast Distance Relay Scheme for Detecting Symmetrical Fault During Power Swing , 2010, IEEE Transactions on Power Delivery.

[6]  H. Kazemi Karegar,et al.  A new method for fault detection during power swing in distance protection , 2009, 2009 6th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology.

[7]  Sam Kodsi Accounting for the Effects of Power System Controllers and Stability on Power Dispatch and Electricity Market Prices , 2005 .

[8]  Carson W. Taylor,et al.  Definition and Classification of Power System Stability , 2004 .

[9]  S.M. Brahma,et al.  Distance Relay With Out-of-Step Blocking Function Using Wavelet Transform , 2007, IEEE Transactions on Power Delivery.

[10]  David Thomas,et al.  A new principle for high resistance earth fault detection during fast power swings for distance protection , 1997 .

[11]  Behnam Mahamedi,et al.  A very fast unblocking scheme for distance protection to detect symmetrical faults during power swings , 2010, 2010 Conference Proceedings IPEC.

[12]  P. Kundur,et al.  Definition and classification of power system stability IEEE/CIGRE joint task force on stability terms and definitions , 2004, IEEE Transactions on Power Systems.

[13]  Daqing Hou,et al.  Zero-setting power-swing blocking protection , 2005 .