An AC/DC interaction analysis on the North China-Central China-East China UHV interconnected power grid

AC/DC interaction is a major concern in the North China-Central China-East China (simplified as `3C') UHV interconnected power grid. The blocking of one or several DC lines is considered the most dangerous contingency because it can cause the power flows in AC lines exceed their stability limits. In this paper, a variant of stability constrained optimal power flow algorithm and an approximate calculation method are developed to study this problem, the algorithm/method is more efficient compared with the one reported in our previous work. An analysis on the interactions among AC/DC lines in the 2012 3C UHV interconnected power grid is performed, and the AC/DC interaction characteristics are partly revealed and the algorithms/methods are verified.

[1]  Yao Zhang,et al.  Selection of HVDC models for stability studies , 2008, 2008 Third International Conference on Electric Utility Deregulation and Restructuring and Power Technologies.

[2]  Claudio A. Canizares,et al.  A vector energy function approach for security analysis of AC/DC systems , 1992 .

[3]  Bradley K. Johnson HVDC models used in stability studies , 1989 .

[4]  Federico Milano,et al.  Voltage stability constrained OPF market models considering N−1 contingency criteria , 2005 .

[5]  Ka Wing Chan,et al.  Direct nonlinear primal–dual interior-point method for transient stability constrained optimal power flow , 2005 .

[6]  Lin Weifang AC Tie-line Power Fluctuation Mechanism and Peak Value Calculation for Two-area Interconnected Power Systems , 2010 .

[7]  Gerd Balzer,et al.  Load-Flow Conditions for HVDC Transmission in Synchronous Networks , 2007 .

[8]  Liu Ping Power swing mechanism analysis of UHV AC pilot project , 2010 .

[9]  Deqiang Gan,et al.  Stability-constrained optimal power flow , 2000 .

[10]  P. Kundur,et al.  Appropriate HVDC transmission simulation models for various power system stability studies , 1998 .

[11]  Michele Trovato,et al.  On-line dynamic preventive control: an algorithm for transient security dispatch , 1998 .

[12]  B. H. Khan,et al.  Stability improvement of power system by simultaneous AC-DC power transmission , 2008 .

[13]  F. Alvarado,et al.  Point of collapse methods applied to AC/DC power systems , 1992 .

[14]  C. Moors,et al.  Design of an undervoltage load shedding scheme for the Hydro-Quebec system , 2003, 2003 IEEE Power Engineering Society General Meeting (IEEE Cat. No.03CH37491).

[15]  IEEE REPORT Functional Model of Two-Terminal HVDC Systems for Transient and Steady-State Stability , 1984, IEEE Transactions on Power Apparatus and Systems.

[16]  M. Anitha,et al.  FDR PSO-based Transient Stability Constrained Optimal Power Flow Solution for Deregulated Power Industry , 2007 .

[17]  Deqiang Gan,et al.  Applications of Stability-Constrained Optimal Power Flow in the East China System , 2010, IEEE Transactions on Power Systems.

[18]  K. Shimomura,et al.  A Study on the Effect of Generation Shedding to Total Transfer Capability by Means of Transient Stability Constrained Optimal Power Flow , 2009, IEEE Transactions on Power Systems.