Total ozone from the ozone monitoring instrument (OMI) using the DOAS technique

This paper describes the algorithm for deriving the total column ozone from spectral radiances and irradiances measured by the Ozone Monitoring Instrument (OMI) on the Earth Observing System Aura satellite. The algorithm is based on the differential optical absorption spectroscopy technique. The main characteristics of the algorithm as well as an error analysis are described. The algorithm has been successfully applied to the first available OMI data. First comparisons with ground-based instruments are very encouraging and clearly show the potential of the method.

[1]  Pawan K. Bhartia,et al.  Science objectives of the ozone monitoring instrument , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[2]  Michael Eisinger,et al.  The Global Ozone Monitoring Experiment (GOME): Mission Concept and First Scientific Results , 1999 .

[3]  R. J. Paur,et al.  The ultraviolet cross-sections of ozone. I. The measurements. II - Results and temperature dependence , 1985 .

[4]  Jay R. Herman,et al.  Earth surface reflectivity climatology at 340–380 nm from TOMS data , 1997 .

[5]  R. B. A. Koelemeijer,et al.  Effects of clouds on ozone column retrieval from GOME UV measurements , 1999 .

[6]  D. Fahey,et al.  Scientific assessment of ozone depletion, 2002 , 2003 .

[7]  Jack Fishman,et al.  Distribution of tropospheric ozone determined from satellite data , 1990 .

[8]  Henk Eskes,et al.  Retrieval and validation of ozone columns derived from measurements of SCIAMACHY on Envisat , 2005 .

[9]  Wolfgang Steinbrecht,et al.  Correlations between tropopause height and total ozone: Implications for long‐term changes , 1998 .

[10]  Heikki Saari,et al.  The ozone monitoring instrument , 2006, IEEE Transactions on Geoscience and Remote Sensing.

[11]  Hongwoo Park,et al.  The Solar Backscatter Ultraviolet (SBUV) and Total Ozone Mapping Spectrometer (TOMS) experiment , 1978 .

[12]  Johannes Orphal,et al.  Ultraviolet and visible absorption cross-sections for HITRAN , 2003 .

[13]  J. Noxon,et al.  Nitrogen Dioxide in the Stratosphere and Troposphere Measured by Ground-Based Absorption Spectroscopy , 1975, Science.

[14]  Nzioka John Muthama,et al.  Global ozone: Past and Future , 2003 .

[15]  Ulrich Platt,et al.  Differential optical absorption spectroscopy (DOAS) , 1994 .

[16]  Piet Stammes,et al.  Cloud pressure retrieval using the O2‐O2 absorption band at 477 nm , 2004 .

[17]  P. Valks Retrieval of total and tropospheric ozone from observations by the Global Ozone Monitoring Experiment , 2003 .