Measurement of digital blood flow using the laser Doppler, impedance and strain-gauge methods

Digital volume changes and blood flow have been measured with impedance and strain-gauge plethysmography as well as with laser Doppler flowmetry. A good agreement was found between the impedance and strain-gauge flow measurements with a correlation coefficient of 0·905. The laser Doppler method recorded minor changes in finger skin blood flow following changes in posture from 30 cm below heart level to 60 cm above heart level. This result can be explained as a consequence of the limited penetration depth of laser light into the skin or as a sign of autoregulation of skin blood flow. In these experiments the total blood flow to the finger underwent major changes.

[1]  R. H. Fox,et al.  Bradykinin formation in human skin as a factor in heat vasodilatation , 1958, The Journal of physiology.

[2]  M. Earley The arterial supply of the thumb, first web and index finger and its surgical application. , 1986, Journal of hand surgery.

[3]  P. Sejrsen,et al.  Autoregulation of blood flow in human cutaneous tissue. , 1973, Acta physiologica Scandinavica.

[4]  F. Bashour,et al.  DIGITAL BLOOD FLOW: I. CORRELATIVE STUDY OF THE ELECTRICAL IMPEDANCE AND THE VENOUS OCCLUSIVE PLETHYSMOGRAPHS. , 1965, Diseases of the chest.

[5]  M. Iki,et al.  Usefulness of fingertip skin temperature for examining peripheral circulatory disturbances of vibrating tool operators. , 1986, Scandinavian journal of work, environment & health.

[6]  P. Oberg,et al.  Laser-Doppler flowmetry--a non-invasive and continuous method for blood flow evaluation in microvascular studies. , 2009, Acta medica Scandinavica. Supplementum.

[7]  I. Swain,et al.  Non-invasive measurement of limb and digit blood flow. , 1986, Journal of biomedical engineering.

[8]  R. J. Whitney,et al.  The measurement of volume changes in human limbs , 1953, The Journal of physiology.

[9]  O G EDHOLM,et al.  The effect of body heating on the circulation in skin and muscle , 1956, The Journal of physiology.

[10]  A. Dittmar,et al.  Heat loss and anticipatory finger vasoconstriction induced by a smoking of a single cigarette , 1985, Physiology & Behavior.

[11]  Gert E. Nilsson,et al.  Evaluation of a Laser Doppler Flowmeter for Measurement of Tissue Blood Flow , 1980, IEEE Transactions on Biomedical Engineering.

[12]  L. Lindblad,et al.  Digital blood pressure after local cooling as a diagnostic tool in traumatic vasospastic disease. , 1982, British journal of industrial medicine.

[13]  A. Minami,et al.  Digital ischemia in baseball players , 1986, The American journal of sports medicine.

[14]  T WINSOR,et al.  The Segmental Plethysmograph , 1957, Angiology.

[15]  A. C. Burton THE RANGE AND VARIABILITY OF THE BLOOD FLOW IN THE HUMAN FINGERS AND THE VASOMOTOR REGULATION OF BODY TEMPERATURE , 1939 .

[16]  J. Kristensen,et al.  Raynaud's phenomenon: blood supply to fingers during indirect cooling, evaluated by laser Doppler flowmetry. , 2008, Clinical physiology.

[17]  J. Edwards,et al.  Digital ischemia as a manifestation of malignancy. , 1987, Annals of surgery.