Water Pipe Networks Performance Assessment: Benchmarking Eight Cases Across the EU Mediterranean Basin

The high level of the non-revenue water (NRW: water not generating revenues) is a well-acknowledged problem water utilities are straggling with in areas facing water scarcity. High NRW values jeopardize the sustainability of water utilities, especially in cases, where these values exceed 50 % of the System Input Volume. WATERLOSS project developed a Decision Support System to help water utility managers design the most effective/efficient NRW reduction strategy. The project’s first step was to evaluate the performance of the water distribution systems selected as case studies. The paper presents the respective results of eight cases from Cyprus, Greece, Italy, France and Spain, based on a modified International Water Association Water Balance adapted to the water pricing practices met across the Mediterranean (high Fixed Charge included in the water tariffs). The results revealed that although almost all cases experience high NRW levels, the high Fixed Charge reduces the actual revenue losses, thus providing a perfect excuse to the managers of the local water utilities do almost nothing to address the actual extent of the NRW problem in their systems.

[1]  Vasilis Kanakoudis,et al.  Using the bimonthly water balance of a non-fully monitored water distribution network with seasonal water demand peaks to define its actual NRW level: the case of Kos town, Greece , 2014 .

[2]  A Rizzo,et al.  Quantifying Meter Under-Registration Caused by the Ball Valves of Roof Tanks (for Indirect Plumbing Systems) , 2005 .

[3]  Malcolm Farley,et al.  Losses in Water Distribution Networks: A Practitioners' Guide to Assessment, Monitoring and Control , 2015 .

[4]  J. A. E. Morrison,et al.  Recent Developments in Application of ‘Bursts and Background Estimates’Concepts for Leakage Management , 1996 .

[5]  Vasilis Kanakoudis,et al.  Assessing the performance of urban water networks across the EU Mediterranean area: The paradox of high NRW levels and absence of respective reduction measures , 2013 .

[6]  C. M. Fontanazza,et al.  Evaluation of the apparent losses caused by water meter under-registration in intermittent water supply. , 2009, Water science and technology : a journal of the International Association on Water Pollution Research.

[7]  Enrique Cabrera,et al.  Performance Indicators for Water Supply Services: Third Edition , 2006 .

[8]  Selami Kara,et al.  Implementation of Hydraulic Modelling for Water-Loss Reduction Through Pressure Management , 2012, Water Resources Management.

[9]  Enrique Cabrera,et al.  Reducing Apparent Losses Caused By Meters Inaccuracies , 2006 .

[10]  A. O. Lambert,et al.  A review of performance indicators for real losses from water supply systems , 1999 .

[11]  Dušan Obradović,et al.  Modelling of demand and losses in real-life water distribution systems , 2000 .

[12]  Vasilis Kanakoudis,et al.  A troubleshooting manual for handling operational problems in water pipe networks , 2004 .

[13]  Julian Thornton Water Loss Control Manual , 2002 .

[14]  Enrique Cabrera,et al.  Leakage Assessment through Water Distribution Network Simulation , 2005 .

[15]  Richard Burrows,et al.  An Integrated Model to Evaluate Losses in Water Distribution Systems , 2009 .

[16]  A. O. Lambert,et al.  International Report: Water losses management and techniques , 2002 .

[17]  Mordecai Feldman,et al.  Aspects of Energy Efficiency in Water Supply systems , 2009 .

[18]  James W. Male,et al.  Identifying and Reducing Losses in Water Distribution Systems , 1985 .