Accuracy evaluation of a six‐degree‐of‐freedom couch using cone beam CT and IsoCal phantom with an in‐house algorithm

Purpose: The accuracy of a six degree of freedom (6DoF) couch was evaluated using a novel method. Methods: Cone beam CT (CBCT) images of a 3D phantom (IsoCal) were acquired with different, known combinations of couch pitch and roll angles. Pitch and roll angles between the maximum allowable values of 357 and 3 degrees were tested in one degree increments. A total of 49 combinations were tested at 0 degrees of yaw (couch rotation angle). The 3D positions of 16 tungsten carbide ball bearings (BBs), each 4 mm in diameter and arranged in a known geometry within the IsoCal phantom, were determined in the 49 image sets with in‐house software. The BB positions at different rotation angles were determined using a rotation matrix from the original BB positions at zero pitch and roll angles. A linear least squares fit method estimated the rotation angles and differences between detected and nominal rotation angles were calculated. This study was conducted for the case with and without extra weight on the couch. Couch walk shifts for the system were investigated using eight combinations of rotation, roll and pitch. Results: A total of 49 CBCT images with voxel sizes 0.5 × 0.5 × 1.0 mm3 were taken for the case without extra weight on the couch. The 16 BBs were determined to evaluate the isocenter translation and rotation differences between the calculated and nominal couch values. Among all 49 calculations, the maximum rotation angle differences were 0.10 degrees for pitch, 0.15 degrees for roll and 0.09 degrees for yaw. The corresponding mean and standard deviation values were 0.028 ± 0.032, −0.043 ± 0.058, and −0.009 ± 0.033 degrees. The maximum translation differences were 0.3 mm in the left–right direction, 0.5 mm in the anterior–posterior direction and 0.4 mm in the superior–inferior direction. The mean values and corresponding standard deviations were 0.07 ± 0.12, −0.05 ± 0.25, and −0.12±0.14 mm for the planes described above. With an 80 kg phantom on the couch, the maximum translation shift was 0.69 mm. The couch walk translation shifts were less than 0.1 mm and rotation shifts were less than 0.1 degree. Conclusions: Errors of a new 6DoF couch were tested using CBCT images of a 3D phantom. The rotation errors were less than 0.3 degree and the translation errors were less than or equal to 0.8 mm in each direction. This level of accuracy is warranted for clinical radiotherapy utilization including stereotactic radiosurgery.

[1]  R L Siddon,et al.  Solution to treatment planning problems using coordinate transformations. , 1981, Medical physics.

[2]  Steven K. Feiner,et al.  Computer graphics: principles and practice (2nd ed.) , 1990 .

[3]  S. Umeyama,et al.  Least-Squares Estimation of Transformation Parameters Between Two Point Patterns , 1991, IEEE Trans. Pattern Anal. Mach. Intell..

[4]  M van Herk,et al.  Computerized design of target margins for treatment uncertainties in conformal radiotherapy. , 1999, International journal of radiation oncology, biology, physics.

[5]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[6]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[7]  William H. Press,et al.  Numerical recipes in C , 2002 .

[8]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[9]  D. Yan,et al.  Computed tomography guided management of interfractional patient variation. , 2005, Seminars in radiation oncology.

[10]  V. Khoo,et al.  X-ray volumetric imaging in image-guided radiotherapy: the new standard in on-treatment imaging. , 2006, International journal of radiation oncology, biology, physics.

[11]  Ravinder Nath,et al.  A method to implement full six-degree target shift corrections for rigid body in image-guided radiotherapy. , 2005, Medical physics.

[12]  P. Munro,et al.  Four-dimensional cone-beam computed tomography using an on-board imager. , 2006, Medical physics.

[13]  Matthias Guckenberger,et al.  Positioning accuracy of cone-beam computed tomography in combination with a HexaPOD robot treatment table. , 2007, International journal of radiation oncology, biology, physics.

[14]  Matthias Guckenberger,et al.  Precision of Image-Guided Radiotherapy (IGRT) in Six Degrees of Freedom and Limitations in Clinical Practice , 2007, Strahlentherapie und Onkologie.

[15]  Fang-Fang Yin,et al.  Use of the BrainLAB ExacTrac X-Ray 6D system in image-guided radiotherapy. , 2008, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[16]  Steve B. Jiang,et al.  Real-time volumetric image reconstruction and 3D tumor localization based on a single x-ray projection image for lung cancer radiotherapy. , 2010, Medical physics.

[17]  K. Rosenzweig,et al.  Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model. , 2010, Medical physics.

[18]  Fang-Fang Yin,et al.  6D image guidance for spinal non-invasive stereotactic body radiation therapy: Comparison between ExacTrac X-ray 6D with kilo-voltage cone-beam CT. , 2010, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[19]  K. Rosenzweig,et al.  Correction of motion artifacts in cone-beam CT using a patient-specific respiratory motion model. , 2010, Medical physics.

[20]  T Mizowaki,et al.  The geometric accuracy of frameless stereotactic radiosurgery using a 6D robotic couch system , 2010, Physics in medicine and biology.

[21]  Jan-Jakob Sonke,et al.  Comparative study of respiratory motion correction techniques in cone-beam computed tomography. , 2011, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[22]  Thierry Gevaert,et al.  Clinical evaluation of a robotic 6-degree of freedom treatment couch for frameless radiosurgery. , 2012, International journal of radiation oncology, biology, physics.

[23]  Song Gao,et al.  SU‐C‐213CD‐04: Evaluation of IsoCal Imaging Isocenter Calibration System for Varian OBI Machines , 2012 .

[24]  J. Williamson,et al.  A protocol to extend the longitudinal coverage of on‐board cone‐beam CT , 2012, Journal of applied clinical medical physics.

[25]  P. Munro,et al.  Evaluation of a new six degrees of freedom couch for radiation therapy. , 2013, Medical physics.

[26]  Qinghui Zhang,et al.  Feasibility study of real-time planning for stereotactic radiosurgery. , 2013, Medical physics.

[27]  Peter Balter,et al.  Evaluation of IsoCal geometric calibration system for Varian linacs equipped with on‐board imager and electronic portal imaging device imaging systems , 2014, Journal of applied clinical medical physics.

[28]  Qinghui Zhang,et al.  Rotation effects on the target-volume margin determination. , 2014, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[29]  A randomized study of the effect of patient positioning on setup reproducibility and dose distribution to organs at risk in radiotherapy of rectal cancer patients , 2015, Radiation oncology.

[30]  A method for volumetric imaging in radiotherapy using single x-ray projection. , 2015, Medical physics.