Current electronic portal imaging devices (EPID) are limited in their ability to provide direct and quick verification and monitoring of patients during both setup and treatment of breathing synchronized radiotherapy (BSRT, including breathing gated, voluntary and forced breath-hold radiotherapy treatment.) These limitations are largely due to their slow image capture rate and poor image quality. An amorphous silicon array flat panel electronic portal imaging device (si-EPID) is emerging to meet the challenge. The purpose of this study is threefold: (1) to characterize the performance of a prototype si-EPID; (2) to compare image quality against that of digitized films; and (3) to evaluate the device in terms of verification of patient setup and monitoring during BSRT. In this study a Varian prototype si-EPID detector array and Clinic accelerator at the University of California Davis Cancer Center were used for imaging. Three quality assurance phantoms: a Lutz PVC phantom, a modified "Las Vegas" phantom, and a RMI model 1151 phantom, were used to characterize the imaging system. A Rando head phantom was used for anthropomorphic imaging tests. Images were obtained with the si-EPID and a Fuji RX film in a Kodak X-Omatic cassette. To investigate the clinical application, two sets of si-EPID images were collected from a lung cancer patient during a 22 s breath-hold and normal breathing. The quality of images obtained with the fast mode was found to be comparable to that obtained with the digitized films. The images with the standard mode were found to be better than the digitized film images. With this prototype si-EPID, it is possible to collect the images at the beginning, middle, and end of each breath-hold for those patients who can hold their breath for longer than 15 s. The si-EPID images can provide a quick verification of the initial patient setup and subsequent treatment position throughout the daily fractionation.
[1]
K. Ohara,et al.
Irradiation synchronized with respiration gate.
,
1989,
International journal of radiation oncology, biology, physics.
[2]
J. Wong,et al.
The use of active breathing control (ABC) to reduce margin for breathing motion.
,
1999,
International journal of radiation oncology, biology, physics.
[3]
J Yorkston,et al.
Initial performance evaluation of an indirect-detection, active matrix flat-panel imager (AMFPI) prototype for megavoltage imaging.
,
1998,
International journal of radiation oncology, biology, physics.
[4]
H. Kubo,et al.
Respiration gated radiotherapy treatment: a technical study.
,
1996,
Physics in medicine and biology.