Effects of prosthesis surface roughness on the failure process of cemented hip implants after stem-cement debonding.

Retrieval studies suggest that the loosening process of the cemented femoral components of total hip arthroplasties is initiated by failure of the bond between the prosthesis and the cement mantle. Finite element (FE) analyses have demonstrated that stem-cement debonding has stress-producing effects in the cement mantle. High interface friction, which corresponds to a degree of surface roughness, reduces these stresses. In experiments, however, debonded rough stems produced more cement damage than polished ones; in the Swedish Hip Register polished stems were clinically superior with respect to stems with a mat surface finish. The purpose of the present study was to investigate this contradiction. For this purpose, global and local FE models with debonded stem-cement interfaces were used to study the effects of prosthesis surface roughness on the cement stresses on a global scale and microscale, respectively. Similar to earlier numerical studies, the global FE model predicted that an increased surface roughness of the stem reduced the stresses in the cement mantle. The local model provided insight in the load-transfer mechanism on a microscale and could explain the experimental and clinical findings. The local cement peak stresses around the asperities of the surface roughness profile increased with increasing surface roughness and decreased again beyond a particular roughness value. Cement abrasion is caused by localized stresses in combination with micromotion. From this study it can be concluded that to minimize cement abrasion, debonded stems should either have a polished microstructure to minimize the local cement stresses or have a profiled macrostructure to minimize micromotions at the stem-cement interface.

[1]  W H Harris,et al.  Is It Advantageous to Strengthen the Cement‐Metal Interface and Use a Collar for Cemented Femoral Components of Total Hip Replacements? , 1992, Clinical orthopaedics and related research.

[2]  K. Bundy,et al.  The effect of surface preparation on metal/bone cement interfacial strength. , 1987, Journal of biomedical materials research.

[3]  T P Harrigan,et al.  A three-dimensional non-linear finite element study of the effect of cement-prosthesis debonding in cemented femoral total hip components. , 1991, Journal of biomechanics.

[4]  R. Crowninshield,et al.  Cement strain measurement surrounding loose and well-fixed femoral component stems. , 1983, Journal of biomedical materials research.

[5]  D L Bartel,et al.  Coulomb frictional interfaces in modeling cemented total hip replacements: a more realistic model. , 1995, Journal of biomechanics.

[6]  A. M. Ahmed,et al.  Metal/cement interface strength in cemented stem fixation , 1984, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[7]  Steven John. Hampton A NONLINEAR FINITE ELEMENT MODEL OF ADHESIVE BOND FAILURE AND APPLICATION TO TOTAL HIP REPLACEMENT ANALYSIS. , 1981 .

[8]  N Verdonschot,et al.  Mechanical effects of stem cement interface characteristics in total hip replacement. , 1996, Clinical orthopaedics and related research.

[9]  R Huiskes,et al.  Some fundamental aspects of human joint replacement. Analyses of stresses and heat conduction in bone-prosthesis structures. , 1980, Acta orthopaedica Scandinavica. Supplementum.

[10]  W H Harris,et al.  Localized osteolysis in stable, non-septic total hip replacement. , 1986, The Journal of bone and joint surgery. American volume.

[11]  P Herberts,et al.  Prognosis of total hip replacement in Sweden. Follow-up of 92,675 operations performed 1978-1990. , 1993, Acta orthopaedica Scandinavica.

[12]  D. L. Gardner,et al.  An Introduction to the Biomechanics of Joints and Joint Replacement , 1982 .

[13]  A R Ingraffea,et al.  Mechanical characteristics of the stem‐cement interface , 1991, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[14]  W J Maloney,et al.  The initiation of failure in cemented femoral components of hip arthroplasties. , 1991, The Journal of bone and joint surgery. British volume.

[15]  N Verdonschot,et al.  Surface roughness of debonded straight-tapered stems in cemented THA reduces subsidence but not cement damage. , 1998, Biomaterials.