Segmentation of artifacts and anatomy in CT metal artifact reduction.

PURPOSE Metal objects present in x-ray computed tomography (CT) scans are accompanied by physical phenomena that render CT projections inconsistent with the linear assumption made for analytical reconstruction. The inconsistencies create artifacts in reconstructed images. Metal artifact reduction algorithms replace the inconsistent projection data passing through metals with estimates of the true underlying projection data, but when the data estimates are inaccurate, secondary artifacts are generated. The secondary artifacts may be as unacceptable as the original metal artifacts; therefore, better projection data estimation is critical. This research uses computer vision techniques to create better estimates of the underlying projection data using observations about the appearance and nature of metal artifacts. METHODS The authors developed a method of estimating underlying projection data through the use of an intermediate image, called the prior image. This method generates the prior image by segmenting regions of the originally reconstructed image, and discriminating between regions that are likely to be metal artifacts and those that are likely to represent anatomical structures. Regions identified as metal artifact are replaced with a constant soft-tissue value, while structures such as bone or air pockets are preserved. This prior image is reprojected (forward projected), and the reprojections guide the estimation of the underlying projection data using previously published interpolation techniques. The algorithm is tested on head CT test cases containing metal implants and compared against existing methods. RESULTS Using the new method of prior image generation on test images, metal artifacts were eliminated or reduced and fewer secondary artifacts were present than with previous methods. The results apply even in the case of multiple metal objects, which is a challenging problem. The authors did not observe secondary artifacts that were comparable to or worse than the original metal artifacts, as sometimes occurred with the other methods. The accuracy of the prior was found to be more critical than the particular interpolation method. CONCLUSIONS Metals produce predictable artifacts in CT images of the head. Using the new method, metal artifacts can be discriminated from anatomy, and the discrimination can be used to reduce metal artifacts.

[1]  P. Joseph,et al.  A Method for Correcting Bone Induced Artifacts in Computed Tomography Scanners , 1978, Journal of computer assisted tomography.

[2]  A. Macovski,et al.  Energy-selective reconstructions in X-ray computerised tomography , 1976, Physics in medicine and biology.

[3]  Patrick Dupont,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998 .

[4]  M. Glas,et al.  Principles of Computerized Tomographic Imaging , 2000 .

[5]  Jeffrey A. Fessler,et al.  Maximum-likelihood dual-energy tomographic image reconstruction , 2002, SPIE Medical Imaging.

[6]  D. Fleischmann,et al.  Evaluation of two iterative techniques for reducing metal artifacts in computed tomography. , 2011, Radiology.

[7]  Rafael C. González,et al.  Digital image processing using MATLAB , 2006 .

[8]  Konstantin Nikolaou,et al.  Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation , 2011, European Radiology.

[9]  Joel G Fletcher,et al.  Metal artifact suppression from reformatted projections in multislice helical CT using dual-front active contours. , 2010, Medical physics.

[10]  L. Xing,et al.  Metal artifact reduction in x-ray computed tomography (CT) by constrained optimization. , 2011, Medical physics.

[11]  Lothar Spies,et al.  Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering. , 2006, Medical physics.

[12]  L. Kochian Author to whom correspondence should be addressed , 2006 .

[13]  Jiang Hsieh,et al.  Computed Tomography: Principles, Design, Artifacts, and Recent Advances, Fourth Edition , 2022 .

[14]  Gary H. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981 .

[15]  Jacob Geleijns,et al.  Development and validation of segmentation and interpolation techniques in sinograms for metal artifact suppression in CT. , 2010, Medical physics.

[16]  E. W. Shrigley Medical Physics , 1944, British medical journal.

[17]  Rainer Raupach,et al.  Normalized metal artifact reduction (NMAR) in computed tomography. , 2010, Medical physics.

[18]  Norbert J. Pelc,et al.  SU‐EE‐A4‐03: Metal Artifact Reduction Algorithm for X‐Ray CT Using a Three‐Pass Approach , 2009 .

[19]  Jing Wang,et al.  Metal artifact reduction in computed tomography by constrained optimization , 2010, Medical Imaging.

[20]  Hengyong Yu,et al.  A segmentation-based method for metal artifact reduction. , 2007, Academic radiology.

[21]  J. H. Hubbell,et al.  XCOM: Photon cross sections on a personal computer , 1987 .

[22]  Jacob Geleijns,et al.  Metal artifact reduction for CT: development, implementation, and clinical comparison of a generic and a scanner-specific technique. , 2012, Medical physics.

[23]  J. Hsieh Adaptive streak artifact reduction in computed tomography resulting from excessive x-ray photon noise. , 1998, Medical physics.

[24]  P. Suetens,et al.  Metal streak artifacts in X-ray computed tomography: a simulation study , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[25]  W. Kalender,et al.  Reduction of CT artifacts caused by metallic implants. , 1987 .

[26]  Rainer Raupach,et al.  Frequency split metal artifact reduction (FSMAR) in computed tomography. , 2012, Medical physics.

[27]  G. Glover,et al.  An algorithm for the reduction of metal clip artifacts in CT reconstructions. , 1981, Medical physics.

[28]  J. Verburg,et al.  CT metal artifact reduction method correcting for beam hardening and missing projections , 2012, Physics in medicine and biology.

[29]  M W Vannier,et al.  Fast iterative algorithm for metal artifact reduction in X-ray CT. , 2000, Academic radiology.

[30]  Patrick Dupont,et al.  Reduction of metal streak artifacts in X-ray computed tomography using a transmission maximum a posteriori algorithm , 1999 .