High quality ion channel analysis on a chip with the NPC technology.

In evaluating ion channel function, electrophysiology, e.g., patch clamping, provides the highest information content. For the analysis of ion channel-modulating compounds, one variant of the patch-clamp technique, the whole-cell configuration, is particularly useful. We present here patch-clamp recordings in the whole-cell configuration and single channel recordings performed with planar patch-clamp chips, which are microstructured from borosilicate glass substrate. The chips are used in the Port-a-Patch, an ion channel research/screening instrument that enables automated patch-clamp experiments on a single cell. A software runs the experiment by executing user-determined protocols for cell positioning, as well as for electrical stimulation and current readout. In various electrophysiological experiments, the high quality of recordings and the versatility of the perfusion of the recorded cells are demonstrated. Quantitative pharmacological experiments are performed on sodium channels expressed in HEK cells using solution volumes in the low microliter range. The exceptionally low volume consumption in the experiments make the system attractive for work on rare or expensive compounds. Due to the low volumes necessary, a rapid solution exchange is facilitated, which is shown on RBL cells. The patch-clamp chip enables a rapid and precise perfusion, allowing sophisticated investigations on ion channel function with the Port-a-Patch.

[1]  T. Jentsch,et al.  Neurological diseases caused by ion-channel mutations , 2000, Current Opinion in Neurobiology.

[2]  R. Keynes The ionic channels in excitable membranes. , 1975, Ciba Foundation symposium.

[3]  Robert H Blick,et al.  Whole cell patch clamp recording performed on a planar glass chip. , 2002, Biophysical journal.

[4]  Clare,et al.  Voltage-gated sodium channels as therapeutic targets. , 2000, Drug discovery today.

[5]  L. Mattheakis,et al.  Assay technologies for screening ion channel targets. , 2001, Current opinion in drug discovery & development.

[6]  B. Sakmann,et al.  Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches , 1981, Pflügers Archiv.

[7]  Lei Wu,et al.  Ion-channel assay technologies: quo vadis? , 2001, Drug discovery today.

[8]  N. Fertig,et al.  Activity of single ion channel proteins detected with a planar microstructure , 2002 .

[9]  D. Mccormick Sequence the Human Genome , 1986, Bio/Technology.

[10]  F. Sigworth,et al.  Patch clamp on a chip. , 2002, Biophysical journal.

[11]  O. Krishtal,et al.  Effect of internal fluoride and phosphate on membrane currents during intracellular dialysis of nerve cells , 1975, Nature.

[12]  M B Jackson,et al.  Single‐Channel Recording , 1998, Current protocols in neuroscience.

[13]  Brian Cox,et al.  HTS approaches to voltage-gated ion channel drug discovery , 1998 .

[14]  W. Catterall,et al.  The IUPHAR compendium of voltage-gated ion channels , 2002 .

[15]  Paul B Bennett,et al.  High throughput ion-channel pharmacology: planar-array-based voltage clamp. , 2003, Assay and drug development technologies.

[16]  P. Christophersen,et al.  High throughput electrophysiology: new perspectives for ion channel drug discovery. , 2003, Receptors & channels.

[17]  M. Curran Potassium ion channels and human disease: phenotypes to drug targets? , 1998, Current opinion in biotechnology.