Detection of stator winding insulation failures: On-line and off-line tests
暂无分享,去创建一个
M. F. Cabanas | G. A. Orcajo | M. F. Cabanas | J. G. Norniella | M. G. Melero | C. H. Rojas | J. M. Cano | F. Pedrayes | G. A. Orcajo | M. Melero | J. Cano | C. Rojas | F. Pedrayes
[1] R. Maier,et al. Protection of squirrel cage induction motor utilizing instantaneous power and phase information , 1990, Conference Record of the 1990 IEEE Industry Applications Society Annual Meeting.
[2] Thomas G. Habetler,et al. A thermal monitoring and parameter tuning scheme for induction machines , 1997, IAS '97. Conference Record of the 1997 IEEE Industry Applications Conference Thirty-Second IAS Annual Meeting.
[3] J.L. Kohler,et al. Alternatives for assessing the electrical integrity of induction motors , 1989, Conference Record of the IEEE Industry Applications Society Annual Meeting,.
[4] Gojko Joksimovic,et al. The detection of inter-turn short circuits in the stator windings of operating motors , 2000, IEEE Trans. Ind. Electron..
[5] Thomas M. Wolbank,et al. Inverter statistics for online detection of stator asymmetries in inverter-fed induction motors , 2003 .
[6] R. M. Tallam,et al. A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix , 2001, 2001 IEEE 32nd Annual Power Electronics Specialists Conference (IEEE Cat. No.01CH37230).
[7] O.P. Malik,et al. Thermal model based digital relaying algorithm for induction motor protection , 1996, Proceedings of 1996 Canadian Conference on Electrical and Computer Engineering.
[8] M. W. Degner,et al. Stator Windings Fault Diagnostics of Induction Machines Operated From Inverters and Soft-Starters Using High-Frequency Negative-Sequence Currents , 2009 .
[9] B. Singh,et al. A review of stator fault monitoring techniques of induction motors , 2005, IEEE Transactions on Energy Conversion.
[10] L. M. Rux,et al. High-voltage DC tests for evaluating stator winding insulation: uniform step, graded step, and ramped test methods , 1997, IEEE 1997 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.
[11] S. Williamson,et al. Analysis of Cage Induction Motors with Stator Winding Faults , 1985, IEEE Power Engineering Review.
[12] H. G. Sedding,et al. The ability of diagnostic tests to estimate the remaining life of stator insulation , 1988 .
[13] Josep M. Guerrero,et al. Online diagnostics in inverter-fed induction machines using high-frequency signal injection , 2004, IEEE Transactions on Industry Applications.
[14] G. Stone,et al. Electrical Insulation for Rotating Machines , 2003 .
[15] A.J. Marques Cardoso,et al. Stator winding fault diagnosis in three-phase synchronous and asynchronous motors, by the extended Park's vector approach , 2000, Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129).
[16] P.E.C.V. Maughan. Partial discharge-a valuable stator winding evaluation tool , 2006, Conference Record of the 2006 IEEE International Symposium on Electrical Insulation.
[17] P.M. John,et al. Data mining - a technique used to extract information from tan delta Measurements on medium Voltage Induction Motors , 2007, AFRICON 2007.
[18] T. G. Habetler,et al. Insulation failure prediction in AC machines using line-neutral voltages , 1998 .
[19] J. Sottile,et al. Condition monitoring of stator windings in induction motors. I. Experimental investigation of the effective negative-sequence impedance detector , 2002 .
[20] W. McDermid,et al. Significance of defects found during high direct-voltage ramp tests , 1999, Proceedings: Electrical Insulation Conference and Electrical Manufacturing and Coil Winding Conference (Cat. No.99CH37035).
[21] Peter Tavner,et al. Monitoring generators and large motors , 1986 .
[22] J. Kapler,et al. Stator winding monitoring , 1998 .
[23] H. Borsi,et al. Partial discharge and dissipation factor behavior of model insulating systems for high voltage rotating machines under different stresses , 2005, IEEE Electrical Insulation Magazine.
[24] J. L. Kohler,et al. Condition monitoring of stator windings in induction motors. II. Experimental investigation of voltage mismatch detectors , 2002 .
[25] F. Briz,et al. On-line stator winding fault diagnosis in inverter-fed AC machines using high frequency signal injection , 2002, Conference Record of the 2002 IEEE Industry Applications Conference. 37th IAS Annual Meeting (Cat. No.02CH37344).
[26] T.G. Habetler,et al. A Sensorless Adaptive Stator Winding Temperature Estimator for Mains-Fed Induction Machines With Continuous-Operation Periodic Duty Cycles , 2006, IEEE Transactions on Industry Applications.
[27] H. Zhu,et al. Comparison of PD and DF test results before and after voltage endurance tests , 2004, Conference Record of the 2004 IEEE International Symposium on Electrical Insulation.
[28] Richard J. Povinelli,et al. Induction Machine Broken Bar and Stator Short-Circuit Fault Diagnostics Based on Three-Phase Stator Current Envelopes , 2008, IEEE Transactions on Industrial Electronics.
[29] E. Wiedenbrug,et al. Early intervention - Impulse testing and turn insulation deterioration in electric motors , 2004 .
[30] N.Y. Abed,et al. Modeling and Characterization of Induction Motor Internal Faults Using Finite-Element and Discrete Wavelet Transforms , 2007, IEEE Transactions on Magnetics.
[31] J. F. Moreno,et al. Realisation of tests to determine the parameters of the thermal model of an induction machine , 2001 .
[32] G.C. Stone. Recent important changes in IEEE motor and generator winding insulation diagnostic testing standards , 2005, IEEE Transactions on Industry Applications.
[33] K. Kimura,et al. New noise rejection techniques on pulse-by-pulse basis for on-line partial discharge measurement of turbine generators , 1996 .
[34] J. S. Hsu,et al. Monitoring of defects in induction motors through air-gap torque observation , 1995 .
[35] E. David,et al. Investigation on the low frequency dielectric response of ground-wall insulation of rotating machine windings , 2003, 2003 Annual Report Conference on Electrical Insulation and Dielectric Phenomena.
[36] W. McDermid,et al. Assessing the condition of hydrogenerator stator winding insulation using the ramped high direct-voltage test method , 2001 .
[37] G. C. Stone,et al. Examples of stator winding partial discharge due to inverter drives , 2000, Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075).
[38] Thomas G. Habetler,et al. A survey of condition monitoring and protection methods for medium voltage induction motors , 2009 .
[39] G. C. Stone,et al. Advancements in partial discharge analysis to diagnose stator winding problems , 2000, Conference Record of the 2000 IEEE International Symposium on Electrical Insulation (Cat. No.00CH37075).
[40] H. Zhu,et al. Quality evaluation of stator coils and bars under thermal cycling stress , 2006, Conference Record of the 2006 IEEE International Symposium on Electrical Insulation.
[41] R. M. Tallam,et al. A robust, on-line turn-fault detection technique for induction machines based on monitoring the sequence component impedance matrix , 2003 .
[42] Luis Romeral,et al. Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition , 2008, IEEE Transactions on Industrial Electronics.
[43] Eric David,et al. The use of time domain spectroscopy as a diagnostic tool for rotating machine windings , 2002, Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316).
[44] F. Filippetti,et al. Closed loop control impact on the diagnosis of induction motors faults , 1999 .
[45] G. C. Stone,et al. Monitoring partial discharges on 4 kV motor windings , 1997, Record of Conference Papers. IEEE Industry Applications Society 44th Annual Petroleum and Chemical Industry Conference.
[46] R. C. Miller,et al. Two recent developments in monitors for large turbine generators , 1988 .
[47] E. Wiedenbrug,et al. Impulse testing and turn insulation deterioration in electric motors , 2003, Conference Record of the 2003 Annual Pulp and Paper Industry Technical Conference, 2003..
[48] Thomas G. Habetler,et al. A new method to detect stator turn-to-turn faults in a closed-loop multiple-motor drive system , 2009, 2009 IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives.
[49] R. Bartnikas,et al. Analysis of multistress-accelerated aged stator bars using a three-phase test arrangement , 2006, IEEE Transactions on Energy Conversion.
[50] Xianghui Huang,et al. The effect of induction motor rotor eccentricity on surge test data , 2005, IEEE International Conference on Electric Machines and Drives, 2005..
[51] R. M. Tallam,et al. A survey of methods for detection of stator related faults in induction machines , 2003, 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003..
[52] V. Fernão Pires,et al. Unsupervised Neural-Network-Based Algorithm for an On-Line Diagnosis of Three-Phase Induction Motor Stator Fault , 2007, IEEE Transactions on Industrial Electronics.
[53] T. G. Habetler,et al. Experimental testing of a neural-network-based turn-fault detection scheme for induction machines under accelerated insulation failure conditions , 2003, 4th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2003. SDEMPED 2003..
[54] R. Bartnikas,et al. Multi-stress aging of stator bars with electrical, thermal, and mechanical stresses as simultaneous acceleration factors , 2004, IEEE Transactions on Energy Conversion.
[55] Xianghui Huang,et al. Using a Surge Tester to Detect Rotor Eccentricity Faults in Induction Motors , 2007, IEEE Transactions on Industry Applications.
[56] G. C. Stone,et al. Experience with compact epoxy-mica capacitors for rotating machine partial discharge detection , 1995, Proceedings:Electrical Electronics Insulation Conference and Electrical Manufacturing & Coil Winding Conference.
[57] K. Younsi,et al. Stator winding failures: contamination, surface discharge, tracking , 1999, Industry Applications Society 46th Annual Petroleum and Chemical Technical Conference (Cat.No. 99CH37000).
[58] Hamid A. Toliyat,et al. Novel frequency-domain-based technique to detect stator interturn faults in induction machines using stator-induced voltages after switch-off , 2002 .
[59] Peter Vas,et al. Parameter Estimation, Condition Monitoring, and Diagnosis of Electrical Machines , 1993 .
[60] Eric David,et al. PDC measurements to assess machine insulation , 2010, IEEE Transactions on Dielectrics and Electrical Insulation.
[61] Ian Culbert,et al. Assessment of insulation condition in rotating machine stators , 1992 .
[62] M. W. Degner,et al. On-line diagnostics in inverter fed induction machines using high frequency signal injection , 2003 .
[63] E. David,et al. Low-frequency dielectric response of asphalt bonded insulation , 2004, Proceedings of the 2004 IEEE International Conference on Solid Dielectrics, 2004. ICSD 2004..
[64] G. C. Stone,et al. Advancements during the past quarter century in on-line monitoring of motor and generator winding insulation , 2002 .
[65] Antonio J. Marques Cardoso,et al. Inter-turn stator winding fault diagnosis in three-phase induction motors, by Park's Vector approach , 1997 .