A high performance microfluidic analyser for phosphate measurements in marine waters using the vanadomolybdate method.

We report a high performance autonomous analytical system based on the vanadomolybdate method for the determination of soluble reactive phosphorus in seawater. The system combines a microfluidic chip manufactured from tinted poly (methyl methacrylate) (PMMA), a custom made syringe pump, embedded control electronics and on-board calibration standards. This "lab-on-a-chip" analytical system was successfully deployed and cross-compared with reference analytical methods in coastal (south west England) and open ocean waters (tropical North Atlantic). The results of the miniaturized system compared well with a reference bench-operated phosphate auto-analyser and showed no significant differences in the analytical results (student's t-test at 95% confidence level). The optical technology used, comprising of tinted PMMA and polished fluidic channels, has allowed an improvement of two orders of magnitude of the limit of detection (52 nM) compared to currently available portable systems based on this method. The system has a wide linear dynamic range 0.1-60 μM, and a good precision (13.6% at 0.4 μM, n=4). The analytical results were corrected for silicate interferences at 0.7 μM, and the measurement frequency was configurable with a sampling throughput of up to 20 samples per hour. This portable micro-analytical system has a low reagent requirement (340 μL per sample) and power consumption (756 J per sample), and has allowed accurate high resolution measurements of soluble reactive phosphorus in seawater.

[1]  Manfred Ehrhardt,et al.  Methods of seawater analysis , 1999 .

[2]  Véronique Garçon,et al.  Phosphate determination in seawater: toward an autonomous electrochemical method. , 2011, Talanta.

[3]  K. Lau,et al.  Validation of a fully autonomous phosphate analyser based on a microfluidic lab-on-a-chip. , 2010, Water science and technology : a journal of the International Association on Water Pollution Research.

[4]  Shoji Motomizu,et al.  Trace and ultratrace analysis methods for the determination of phosphorus by flow-injection techniques. , 2005, Talanta.

[5]  A. Derr,et al.  Real-time and long-term monitoring of phosphate using the in-situ CYCLE sensor , 2009, OCEANS 2009.

[6]  Jörg P Kutter,et al.  Optical detection in microfluidic systems , 2009, Electrophoresis.

[7]  I. V. Tóth,et al.  Spectrophotometric flow system using vanadomolybdophosphate detection chemistry and a liquid waveguide capillary cell for the determination of phosphate with improved sensitivity in surface and ground water samples , 2008 .

[8]  O. Svensson,et al.  Optimising the determination of nitrate and phosphate in sea water with ion chromatography using experimental design , 1997 .

[9]  S. Z. Ali,et al.  Estimation of Phosphorus in Native and Modified Starches. Improvement in the Molybdovanadophosphoric Acid Method , 1987 .

[10]  J. Chi,et al.  Automated analysis of nanomolar concentrations of phosphate in natural waters with liquid waveguide. , 2002, Environmental science & technology.

[11]  Matthew C. Mowlem,et al.  Lab-on-chip measurement of nitrate and nitrite for in situ analysis of natural waters. , 2012, Environmental science & technology.

[12]  A. E. Greenberg,et al.  Standard methods for the examination of water and wastewater: 1991 supplement to the 17th edition , 1991 .

[13]  J. Ruzicka,et al.  Flow injection analyses , 1975 .

[14]  J. P. Riley,et al.  A modified single solution method for the determination of phosphate in natural waters , 1962 .

[15]  B. D. Todd,et al.  Patterns of inorganic phosphate uptake in Cassiopea xamachana: a bioindicator species. , 2006, Marine pollution bulletin.

[16]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[17]  E. Achterberg,et al.  Biological and physical forcing of carbonate chemistry in an upwelling filament off northwest Africa: Results from a Lagrangian study , 2012 .

[18]  Dermot Diamond,et al.  Autonomous microfluidic system for phosphate detection. , 2007, Talanta.

[19]  Dermot Diamond,et al.  Absorbance Based Light Emitting Diode Optical Sensors and Sensing Devices , 2008, Sensors.

[20]  Matthew C. Mowlem,et al.  Reduction of surface roughness for optical quality microfluidic devices in PMMA and COC , 2010 .

[21]  Toby Tyrrell,et al.  The relative influences of nitrogen and phosphorus on oceanic primary production , 1999, Nature.

[22]  Tommy D. Dickey,et al.  Emerging ocean observations for interdisciplinary data assimilation systems , 2003 .

[23]  Víctor Cerdà,et al.  Flow analysis techniques for phosphorus: an overview. , 2005, Talanta.

[24]  K. Ruttenberg 10.13 – The Global Phosphorus Cycle , 2014 .

[25]  P. Dorval,et al.  CHEMINI: A new in situ CHEmical MINIaturized analyzer , 2009 .

[26]  Matthew C. Mowlem,et al.  Microfluidic colourimetric chemical analysis system: application to nitrite detection. , 2010 .

[27]  K. Föllmi,et al.  The phosphorus cycle, phosphogenesis and marine phosphate-rich deposits , 1996 .

[28]  Véronique Garçon,et al.  An autonomous nutrient analyzer for oceanic long-term in situ biogeochemical monitoring. , 2003, Analytical chemistry.

[29]  D. Washington,et al.  Standard Methods for the Examination of Water and Wastewater , 1971 .

[30]  P. Worsfold,et al.  High temporal and spatial resolution environmental monitoring using flow injection with spectroscopic detection , 2002 .

[31]  Stephen J. Haswell,et al.  Development of a micro flow injection manifold for the determination of orthophosphate , 1995 .

[32]  F. Righini,et al.  Ion chromatographic determination of nutrients in sea water , 1995 .

[33]  Ralf D. Prien,et al.  The future of chemical in situ sensors , 2007 .

[34]  Scott C. Doney,et al.  The Growing Human Footprint on Coastal and Open-Ocean Biogeochemistry , 2010, Science.

[35]  Dermot Diamond,et al.  The determination of phosphorus in a microfluidic manifold demonstrating long-term reagent lifetime and chemical stability utilising a colorimetric method , 2003 .

[36]  Hywel Morgan,et al.  Nanomolar detection with high sensitivity microfluidic absorption cells manufactured in tinted PMMA for chemical analysis. , 2011, Talanta.

[37]  P. Worsfold,et al.  Determination of nanomolar concentrations of phosphate in natural waters using flow injection with a long path length liquid waveguide capillary cell and solid-state spectrophotometric detection. , 2007, Talanta.

[38]  E. Achterberg,et al.  Relative influence of nitrogen and phosphorous availability on phytoplankton physiology and productivity in the oligotrophic sub‐tropical North Atlantic Ocean , 2008 .

[39]  Higinio Mora-Mora,et al.  μ-MAR: Multiplane 3D Marker based Registration for depth-sensing cameras , 2015, Expert Syst. Appl..

[40]  Danielle R. Greenhow,et al.  High-resolution in situ analysis of nitrate and phosphate in the oligotrophic ocean. , 2007, Environmental science & technology.

[41]  P. Worsfold Challenges in the Determination of Nutrient Species in Natural Waters , 2006 .