Investigation of a scanned cylindrical ultrasound system for breast hyperthermia

This paper investigates the feasibility of a scanned cylindrical ultrasound system for producing uniform heating from the central to the superficial portions of the breast or localized heating within the breast at a specific location. The proposed system consists of plane ultrasound transducer(s) mounted on a scanned cylindrical support. The breast was immersed in water and surrounded by this system during the treatment. The control parameters considered are the size of the transducer, the ultrasound frequency, the scan angle and the shifting distance between the axes of the breast and the system. Three-dimensional acoustical and thermal models were used to calculate the temperature distribution. Non-perfused phantom experiments were performed to verify the simulation results. Simulation results indicate that high frequency ultrasound could be used for the superficial heating, and the scan angle of the transducer could be varied to obtain an appropriate high temperature region to cover the desired treatment region. Low frequency ultrasound could be used for deep heating and the high temperature region could be moved by shifting the system. In addition, a combination of low and high frequency ultrasound could result in a portion treatment from the central to the superficial breast or an entire breast treatment. Good agreement was obtained between non-perfused experiments and simulation results. The findings of this study can be used to determine the effects of the control parameters of this system, as well as to select the optimal parameters for a specific treatment.

[1]  H. H. Penns Analysis of tissue and arterial blood temperatures in the resting human forearm , 1948 .

[2]  J W Hunt,et al.  Transmission of ultrasound beams through human tissue--focusing and attenuation studies. , 1979, Ultrasound in medicine & biology.

[3]  H L Liou,et al.  Self-tuning fuzzy logic control for ultrasound hyperthermia with reference temperature based on objective functions. , 1999, Medical physics.

[4]  E. Burdette,et al.  Design of an ultrasonic therapy system for breast cancer treatment. , 1996, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[5]  G K Svensson,et al.  Local hyperthermia, radiation therapy, and chemotherapy in patients with local-regional recurrence of breast carcinoma. , 1993, International journal of radiation oncology, biology, physics.

[6]  E. Madsen,et al.  Tissue mimicking materials for ultrasound phantoms. , 1978, Medical physics.

[7]  J. Kumaradas,et al.  Optimization of a beam shaping bolus for superficial microwave hyperthermia waveguide applicators using a finite element method. , 2003, Physics in medicine and biology.

[8]  K. Hynynen,et al.  Temperature measurements during ultrasound hyperthermia. , 1989, Medical physics.

[9]  K. Hynynen,et al.  Simulation study for thermal dose optimization in ultrasound surgery of the breast. , 2004, Medical physics.

[10]  Michael C. Kolios,et al.  A theoretical comparison of energy sources--microwave, ultrasound and laser--for interstitial thermal therapy. , 1998, Physics in medicine and biology.

[11]  J. Overgaard The current and potential role of hyperthermia in radiotherapy. , 1989, International journal of radiation oncology, biology, physics.

[12]  K. Hynynen,et al.  Simulations of scanned focused ultrasound hyperthermia. the effects of scanning speed and pattern on the temperature fluctuations at the focal depth , 1988, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[13]  C. Cain,et al.  A spherical-section ultrasound phased array applicator for deep localized hyperthermia , 1991, IEEE Transactions on Biomedical Engineering.

[14]  T. Kuo,et al.  One-dimensional phased array with mechanical motion for conformal ultrasound hyperthermia. , 2003, Physics in medicine and biology.

[15]  J. Yen,et al.  Pilot point temperature regulation for thermal lesion control during ultrasound thermal therapy , 2004, Medical and Biological Engineering and Computing.

[16]  H. H. Pennes Analysis of tissue and arterial blood temperatures in the resting human forearm. 1948. , 1948, Journal of applied physiology.

[17]  A. Hart,et al.  Comparison of radiotherapy alone with radiotherapy plus hyperthermia in locally advanced pelvic tumours: a prospective, randomised, multicentre trial , 2000, The Lancet.

[18]  K. B. Ocheltree,et al.  Sound field calculation for rectangular sources , 1989, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[19]  J. Yen,et al.  Relationship between acoustic aperture size and tumor conditions for external ultrasound hyperthermia. , 1999, Medical physics.

[20]  K. Hynynen,et al.  A 256-element ultrasonic phased array system for the treatment of large volumes of deep seated tissue , 1999, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.