Three DNA sequencing methods using capillary gel electrophoresis and laser-induced fluorescence.

Capillary gel electrophoresis is demonstrated for the four-spectral-channel sequencing technique of Smith, the two-spectral-channel sequencing technique of Prober, and the one-spectral-channel sequencing technique of Richardson and Tabor. Sequencing rates up to 1000 bases/h are obtained at electric field strengths of 465 V/cm. At lower electric field strengths, capillary electrophoresis produces useful data for fragments greater than 550 nucleotides in length with 2 times better resolution than slab gel electrophoresis. An on-column detector produces detection limits of 200 zmol (1 zmol = 10(-21) mol = 600 molecules) for the four-spectral-channel technique. A postcolumn detector, based on the sheath flow cuvette, produces detection limits of 20 and 2 zmol for the two- and one-spectral-channel techniques, respectively.

[1]  A. Paulus,et al.  Rapid separation and purification of oligonucleotides by high-performance capillary gel electrophoresis. , 1988, Proceedings of the National Academy of Sciences of the United States of America.

[2]  Lloyd M. Smith,et al.  Fluorescence detection in automated DNA sequence analysis , 1986, Nature.

[3]  J. Lyons,et al.  Optimization of flow cells for fluorescence detection in liquid chromatography , 1982 .

[4]  J. M. Prober,et al.  A system for rapid DNA sequencing with fluorescent chain-terminating dideoxynucleotides. , 1987, Science.

[5]  N. Dovichi,et al.  Interaction of capillary zone electrophoresis with a sheath flow cuvette detector , 1990 .

[6]  Barry L. Karger,et al.  Analytical and micropreparative ultrahigh resolution of oligonucleotides by polyacrylamide gel high-performance capillary electrophoresis , 1990 .

[7]  W. Ansorge,et al.  A non-radioactive automated method for DNA sequence determination. , 1986, Journal of biochemical and biophysical methods.

[8]  W. Gilbert,et al.  A new method for sequencing DNA. , 1977, Proceedings of the National Academy of Sciences of the United States of America.

[9]  A. Paulus,et al.  Calibration of polyacrylamide gel columns for the separation of oligonucleotides by capillary electrophoresis , 1990, Electrophoresis.

[10]  J. Edström,et al.  Nucleotide Analysis on the Cyto-Scale , 1953, Nature.

[11]  R A Mathies,et al.  Single-molecule fluorescence detection: autocorrelation criterion and experimental realization with phycoerythrin. , 1989, Proceedings of the National Academy of Sciences of the United States of America.

[12]  S. Hjertén High-performance electrophoresis: the electrophoretic counterpart of high-performance liquid chromatography , 1983 .

[13]  H. Swerdlow,et al.  Capillary gel electrophoresis for rapid, high resolution DNA sequencing. , 1990, Nucleic acids research.

[14]  N. Dovichi,et al.  High-sensitivity fluorescence detector fluorescein isothiocyanate derivatives of amino acids separated by capillary zone electrophoresis. , 1989, Journal of chromatography.

[15]  H. Erfle,et al.  One label, one tube, Sanger DNA sequencing in one and two lanes on a gel. , 1990, Nucleic acids research.

[16]  J. Jett,et al.  Attogram detection limit for aqueous dye samples by laser-induced fluorescence. , 1983, Science.

[17]  J. Luckey,et al.  High-speed separations of DNA sequencing reactions by capillary electrophoresis. , 1990, Analytical chemistry.

[18]  J H Jett,et al.  Laser-induced fluorescence of flowing samples as an approach to single-molecule detection in liquids. , 1984, Analytical chemistry.

[19]  B. Karger,et al.  High-performance sodium dodecyl sulfate polyacrylamide gel capillary electrophoresis of peptides and proteins. , 1987, Journal of chromatography.

[20]  J H Jett,et al.  Detection of single molecules of phycoerythrin in hydrodynamically focused flows by laser-induced fluorescence. , 1987, Analytical chemistry.

[21]  G. Schomburg,et al.  Production of polyacrylamide gel filled capillaries for capillary gel electrophoresis (CGE) : influence of capillary surface pretreatment on performance and stability , 1990 .

[22]  J. Edström Separation and determination of purines and pyrimidine nucleotides in picogram amounts. , 1956 .

[23]  T. Hirschfeld,et al.  Quantum efficiency independence of the time integrated emission from a fluorescent molecule. , 1976, Applied optics.

[24]  R A Mathies,et al.  Optimization of high-sensitivity fluorescence detection. , 1990, Analytical chemistry.

[25]  C. Richardson,et al.  DNA sequence analysis with a modified bacteriophage T7 DNA polymerase. Effect of pyrophosphorolysis and metal ions. , 1990, The Journal of biological chemistry.

[26]  N. Dovichi,et al.  Subattomole amino acid analysis by capillary zone electrophoresis and laser-induced fluorescence. , 1988, Science.

[27]  F. Sanger,et al.  DNA sequencing with chain-terminating inhibitors. , 1977, Proceedings of the National Academy of Sciences of the United States of America.

[28]  H. Swerdlow,et al.  Capillary gel electrophoresis for DNA sequencing. Laser-induced fluorescence detection with the sheath flow cuvette. , 1990, Journal of chromatography.

[29]  B. Karger,et al.  Separation and analysis of DNA sequence reaction products by capillary gel electrophoresis. , 1990, Journal of chromatography.

[30]  L. M. Smith,et al.  High speed DNA sequencing by capillary electrophoresis. , 1990, Nucleic acids research.

[31]  J B Shear,et al.  Fluorescence detection in capillary zone electrophoresis using a charge-coupled device with time-delayed integration. , 1991, Analytical chemistry.