Factors affecting the characteristics of earthing systems under transients by FEM
暂无分享,去创建一个
[1] N.M. Nor,et al. Characterization of ionization phenomena in soils under fast impulses , 2006, IEEE Transactions on Power Delivery.
[2] Bojan Štumberger,et al. The FEM-BEM analysis of complex grounding systems , 2003 .
[3] Mladen Trlep,et al. The analysis of complex grounding systems by FEM , 1998 .
[4] K. Ramar,et al. Validation of the Calculation and Measurement Techniques of Earth Resistance Values , 2008 .
[5] H. Griffiths,et al. Performance of earthing systems of low resistivity soils , 2006, IEEE Transactions on Power Delivery.
[6] Zlatan Stojković,et al. Sensitivity analysis of experimentally determined grounding grid impulse characteristics , 1998 .
[7] E. E. Oettle. A new general estimation curve for predicting the impulse impedance of concentrated earth electrodes , 1988 .
[8] Norazman Mohamad Nor,et al. Field tests: Performances of practical earthing systems under lightning impulses , 2013 .
[9] M. Trlep,et al. The simulation of the soil ionization phenomenon around the grounding system by the finite element method , 2006, IEEE Transactions on Magnetics.
[10] H. R. Armstrong. Grounding Electrode Characteristics from Model Tests [includes discussion] , 1953, Transactions of the American Institute of Electrical Engineers. Part III: Power Apparatus and Systems.
[11] A. Liew,et al. Dynamic model of impulse characteristics of concentrated earths , 1974 .
[12] M. Trlep,et al. Determination of Threshold Electric Field of Practical Earthing Systems by FEM and Experimental Work , 2013, IEEE Transactions on Power Delivery.
[13] Vernon Cooray,et al. On the physical properties of discharges in sand under lightning impulses , 1993 .
[14] A. Ametani,et al. Experimental study of current-dependent grounding resistance of rod electrode , 2005, IEEE Transactions on Power Delivery.
[15] K. Ramar,et al. Investigations of Two-Layer Earth Parameters at Low Voltage: Measurements and Calculations , 2009 .
[16] S. Abdullah,et al. Comparison between utility sub-station and imitative earthing systems when subjected under lightning response , 2012 .
[17] E. B. Shim,et al. Lightning characteristics in Korea and lightning performance of power systems , 2002, IEEE/PES Transmission and Distribution Conference and Exhibition.
[18] A. M. Mousa. The soil ionization gradient associated with discharge of high currents into concentrated electrodes , 1994 .
[19] P. L. Bellaschi,et al. Impulse and 60-Cycle Characteristics of Driven Grounds - II , 1941, Transactions of the American Institute of Electrical Engineers.
[20] G. Valtorta,et al. Temporary overvoltages due to ground faults in MV networks , 2009 .
[21] G. Valtorta,et al. Ground Fault Temporary Overvoltages in MV Networks: Evaluation and Experimental Tests , 2012, IEEE Transactions on Power Delivery.
[22] A. Kalyuzhny. Switching Capacitor Bank Back-to-Back to Underground Cables , 2013, IEEE Transactions on Power Delivery.
[23] Akihiro Ametani,et al. Measurements of grounding resistances for high impulse currents , 1998 .
[24] H. Griffiths,et al. Determination of threshold electric field E/sub C/ of soil under high impulse currents , 2005, IEEE Transactions on Power Delivery.