Optimization of a tabletop high-repetition-rate soft x-ray laser pumped in double-pulse single-beam grazing incidence.

This Letter reports on the optimization of a tabletop nickel-like molybdenum transient collisionally excited soft x-ray laser (SXRL) at 18.9 nm performed by a double-pulse single-beam grazing incidence pumping (DGRIP). This scheme allows for the first time, to our knowledge, the full control of the pump laser parameters including the pre-pulse duration optimally generating the SXRL amplifier under a grazing incidence. The single-beam geometry of the collinear double-pulse propagation guarantees the ideal overlap of the pre-pulse and main pulse from shot to shot resulting in a more efficient and highly stable SXRL output. SXRL energies up to 2.2 microJ are obtained with a total pump energy less than 1 J for several hours at a 10 Hz repetition rate without realignment under once optimized double pumping pulse parameters including energy ratio, time delay, pre-pulse and main pulse durations, and line focus width.

[1]  Vyacheslav N. Shlyaptsev,et al.  Short Pulse X-Ray Laser at 32.6 nm Based on Transient Gain in Ne-like Titanium , 1997 .

[2]  Yoshiaki Kato,et al.  Development of a pumping laser system for x-ray laser research. , 2003, Applied optics.

[3]  Annie Klisnick,et al.  Transient collisionally excited X-ray laser in nickel-like zirconium pumped with the PHELIX laser facility , 2004 .

[4]  M. Marconi,et al.  Saturated high-repetition-rate 18.9-nm tabletop laser in nickellike molybdenum. , 2005, Optics letters.

[5]  R Keenan,et al.  High-repetition-rate grazing-incidence pumped x-ray laser operating at 18.9 nm. , 2005, Physical review letters.

[6]  J. Rocca,et al.  Saturated 13.2 nm high-repetition-rate laser in nickellike cadmium. , 2005, Optics letters.

[7]  C. Menoni,et al.  High-brightness injection-seeded soft-x-ray-laser amplifier using a solid target. , 2006, Physical review letters.

[8]  G. J. Pert Optimizing the performance of nickel-like collisionally pumped x-ray lasers , 2006 .

[9]  G Jamelot,et al.  Optimization toward a high-average-brightness soft-x-ray laser pumped at grazing incidence. , 2007, Optics letters.

[10]  Gerard Jamelot,et al.  Design and demonstration of a high-energy booster amplifier for a high-repetition rate petawatt class laser system. , 2007, Optics letters.

[11]  G. Jamelot,et al.  Quantitative study of 10 Hz operation of a soft x-ray laser-energy stability and target considerations. , 2007, Optics Express.

[12]  G. Jamelot,et al.  Characterization of a transient collisional Ni-like molybdenum soft x-ray laser pumped in grazing incidence , 2008 .

[13]  Tae Jun Yu,et al.  Demonstration of a saturated Ni-like Ag x-ray laser pumped by a single profiled laser pulse from a 10-Hz Ti:sapphire laser system , 2008 .

[14]  B. Zielbauer,et al.  An improved double-pulse non-normal incidence pumping geometry for transient collisionally excited soft X-ray lasers , 2008 .

[15]  P. Nickles,et al.  High-repetition-rate chirped-pulse-amplification thin-disk laser system with joule-level pulse energy. , 2009, Optics letters.

[16]  J. Rocca,et al.  Demonstration of an all-diode-pumped soft x-ray laser. , 2009, Optics letters.

[17]  Felix Staub,et al.  Saturated X-ray lasing in Ni-like Sn at 11.9 nm using the GRIP scheme , 2009 .