Multielectrode spiral cuff for selective stimulation of nerve fibres.

In this paper we present the modelling, design, and initial experimental testing of a nerve cuff multielectrode system for selective stimulation of fibres in superficial peripheral nerve trunk regions which is capable of making a selective activation of multiple muscles. The developed multielectrode nerve cuff consists of 14 platinum stimulating electrodes embedded within a self-curling sheet of biocompatible insulation, exhibiting a spiral transverse cross-section. The spiral shape of the system is such that the number of stimulating electrodes which can be utilized depends on the diameter of the stimulated nerve. Nerves with a greater diameter automatically make use of more electrodes than thin ones. The development was based on results obtained by a histological examination of the peripheral nerves which were planned to be stimulated, and on models of excitation of myelinated nerve fibres. The modelling objectives were to determine the electric field that would be generated within a nerve trunk by a specific electrode. Moreover, the extent of initial excitation of the nerve fibres within the superficial region of the dog sciatic nerve elicited by a certain discrete stimulating electrode was predicted. For this purpose a calculation of activating function for six positions where the nerve fibres were supposed to lie within the longitudinally dissected sciatic nerve was performed. In two acute experiments on the sciatic nerve of the dog the objective was to characterize the effectiveness of the multielectrode system in monopolar selective stimulation of the superficial regions, innervating the gastrocnemius and tibialis anterior muscle. A selectivity preliminary tested by measuring the myoelectric activity of the gastrocnemius and tibialis anterior muscle after 2 months showed good results in both animals.

[1]  J. Mortimer,et al.  Selective activation of small motor axons by quasitrapezoidal current pulses , 1991, IEEE Transactions on Biomedical Engineering.

[2]  C. R. Taylor,et al.  Distribution of fiber types in locomotory muscles of dogs. , 1982, The American journal of anatomy.

[3]  Effect Of Pulsewidth And Delay On Stimulating Electrode Charge Injection In-vitro , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[4]  J. Holsheimer,et al.  A modeling study of nerve fascicle stimulation , 1989, IEEE Transactions on Biomedical Engineering.

[5]  D. B. Heppner,et al.  Considerations of quasi-stationarity in electrophysiological systems. , 1967, The Bulletin of mathematical biophysics.

[6]  F. Rattay Analysis of Models for External Stimulation of Axons , 1986, IEEE Transactions on Biomedical Engineering.

[7]  Barry Coburn,et al.  A Theoretical Study of Epidural Electrical Stimulation of the Spinal Cord Part I: Finite Element Analysis of Stimulus Fields , 1985, IEEE Transactions on Biomedical Engineering.

[8]  D. Durand,et al.  FINITE DIFFERENCE MODELING OF NERVE CUFF ELECTRIC FIELDS. , 1987 .

[9]  P.H. Veltink,et al.  Simulation of intrafascicular and extraneural nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[10]  F Rattay,et al.  Ways to approximate current-distance relations for electrically stimulated fibers. , 1987, Journal of theoretical biology.

[11]  Moshe Solomonow,et al.  Manipulation of Muscle Force with Various Firing Rate and Recruitment Control Strategies , 1987, IEEE Transactions on Biomedical Engineering.

[12]  J. Mortimer,et al.  A spiral nerve cuff electrode for peripheral nerve stimulation , 1988, IEEE Transactions on Biomedical Engineering.

[13]  J. Wickham,et al.  The urethral pressure profile. , 1969, British journal of urology.

[14]  R. Waters,et al.  Functional electrical stimulation of the peroneal nerve for hemiplegia. Long-term clinical follow-up. , 1985, The Journal of bone and joint surgery. American volume.

[15]  A method for evaluating the selectivity of electrodes implanted for nerve simulation , 1991, IEEE Transactions on Biomedical Engineering.

[16]  J. Swett,et al.  Chapter 10 – Electrical Stimulation of Peripheral Nerve , 1981 .

[17]  L. S. Robblee,et al.  The Electrochemistry Of Electrical Stimulation , 1990, [1990] Proceedings of the Twelfth Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[18]  D. Mcneal Analysis of a Model for Excitation of Myelinated Nerve , 1976, IEEE Transactions on Biomedical Engineering.

[19]  D. A. Ksienski,et al.  A nerve cuff technique for selective excitation of peripheral nerve trunk regions , 1990, IEEE Transactions on Biomedical Engineering.

[20]  H Thoma,et al.  First implantation of a 16-channel electric stimulation device in the human body. , 1983, Transactions - American Society for Artificial Internal Organs.

[21]  J. Mortimer,et al.  The Effect of Stimulus Parameters on the Recruitment Characteristics of Direct Nerve Stimulation , 1983, IEEE Transactions on Biomedical Engineering.

[22]  Dominique M. Durand,et al.  MODELING OF MAMMALIAN MYELINATED NERVE FOR FUNCTIONAL NEUROMUSCULAR STIMULATION. , 1987 .

[23]  P.H. Veltink,et al.  Influences of stimulation conditions on recruitment of myelinated nerve fibres: a model study , 1988, IEEE Transactions on Biomedical Engineering.