Reproducibility of the abdominal and chest wall position by voluntary breath-hold technique using a laser-based monitoring and visual feedback system.

PURPOSE The voluntary breath-hold (BH) technique is a simple method to control the respiration-related motion of a tumor during irradiation. However, the abdominal and chest wall position may not be accurately reproduced using the BH technique. The purpose of this study was to examine whether visual feedback can reduce the fluctuation in wall motion during BH using a new respiratory monitoring device. METHODS AND MATERIALS We developed a laser-based BH monitoring and visual feedback system. For this study, five healthy volunteers were enrolled. The volunteers, practicing abdominal breathing, performed shallow end-expiration BH (SEBH), shallow end-inspiration BH (SIBH), and deep end-inspiration BH (DIBH) with or without visual feedback. The abdominal and chest wall positions were measured at 80-ms intervals during BHs. RESULTS The fluctuation in the chest wall position was smaller than that of the abdominal wall position. The reproducibility of the wall position was improved by visual feedback. With a monitoring device, visual feedback reduced the mean deviation of the abdominal wall from 2.1 +/- 1.3 mm to 1.5 +/- 0.5 mm, 2.5 +/- 1.9 mm to 1.1 +/- 0.4 mm, and 6.6 +/- 2.4 mm to 2.6 +/- 1.4 mm in SEBH, SIBH, and DIBH, respectively. CONCLUSIONS Volunteers can perform the BH maneuver in a highly reproducible fashion when informed about the position of the wall, although in the case of DIBH, the deviation in the wall position remained substantial.

[1]  T Kozuka,et al.  Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study. , 1998, Radiology.

[2]  E. Yorke,et al.  Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. , 2004, Seminars in radiation oncology.

[3]  W. Stanford,et al.  Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomography. , 1990, International journal of radiation oncology, biology, physics.

[4]  Radhe Mohan,et al.  Audio-visual biofeedback for respiratory-gated radiotherapy: impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[5]  Hiroshi Onishi,et al.  A new irradiation system for lung cancer combining linear accelerator, computed tomography, patient self-breath-holding, and patient-directed beam-control without respiratory monitoring devices. , 2003, International journal of radiation oncology, biology, physics.

[6]  C. Ling,et al.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging. , 2002, International journal of radiation oncology, biology, physics.

[7]  S Minohara,et al.  Respiratory gated irradiation system for heavy-ion radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[8]  Margrit Betke,et al.  The correlation between internal and external markers for abdominal tumors: implications for respiratory gating. , 2003, International journal of radiation oncology, biology, physics.

[9]  Hiroshi Honda,et al.  A machine vision system with CCD cameras for patient positioning in radiotherapy: a preliminary report. , 2005, Fukuoka igaku zasshi = Hukuoka acta medica.

[10]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[11]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[12]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[13]  K. Lam,et al.  Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging. , 1998, International journal of radiation oncology, biology, physics.

[14]  Hans-Ulrich Kauczor,et al.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.

[15]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[16]  M. Halliwell,et al.  Ultrasound quantitation of respiratory organ motion in the upper abdomen. , 1994, The British journal of radiology.

[17]  Michael B Sharpe,et al.  Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. , 2003, International journal of radiation oncology, biology, physics.

[18]  Hans-Peter Meinzer,et al.  Influence of different breathing maneuvers on internal and external organ motion: use of fiducial markers in dynamic MRI. , 2005, International journal of radiation oncology, biology, physics.

[19]  Tomoki Kimura,et al.  Reproducibility of organ position using voluntary breath-hold method with spirometer for extracranial stereotactic radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[20]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[21]  Richard L Ehman,et al.  Intermittent-mode CT fluoroscopy-guided biopsy of the lung or upper abdomen with breath-hold monitoring and feedback: system development and feasibility. , 2003, Radiology.

[22]  George Starkschall,et al.  Respiration-correlated treatment delivery using feedback-guided breath hold: a technical study. , 2005, Medical physics.